{"product_id":"eaton-emi201-10-metered-input-rack-pdu","title":"Eaton EMI201-10 – 24-Outlet Metered Rack PDU 5.76kW","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Eaton EMI201-10 metered rack PDU is built for data center and colocation cabinet deployments running standard 120\/240V split-phase power to a rack of NEMA 5-20R equipment. As a metered PDU, it provides local and network-accessible visibility into input load, supporting rack PDU installation projects where capacity planning and circuit balancing are priorities. This unit is a common choice for colocation cabinet buildouts and server room upgrades standardizing on 24 individually accessible 5-20R outlets.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMI201-10_C.jpg?v=1782802195\" alt=\"Eaton EMI201-10 rack PDU\" style=\"max-width:100%;height:auto;\"\u003e\n\u003cp\u003eThe Eaton EMI201-10 is a metered input rack PDU rated for 120\/240V input at 24A, delivering up to 5.76 kW to connected equipment. It provides 24 total outlets, all standard NEMA 5-20R receptacles, making it well suited for racks populated with servers, switches, and other 120V-class IT equipment that use standard power cords rather than IEC C13\/C19 connections. The unit connects to facility power through a NEMA L14-30P plug on a 10-foot cord, a split-phase connector commonly used in data center and colocation electrical infrastructure where 120\/240V circuits are available. A local display and remote monitoring capability, including an Ethernet interface and RS-232 serial port, let facilities and IT staff verify load conditions during commissioning and track consumption over time. This makes the EMI201-10 a practical option for data center rack PDU installation where the connected equipment list is largely NEMA 5-20R rather than IEC-terminated. The 0U vertical mounting profile runs the height of the rack enclosure, keeping all 24 outlets accessible without consuming horizontal rack unit space needed for servers and network gear. Colocation providers and enterprise IT teams often specify this configuration when standardizing racks around commodity servers and network appliances that ship with standard NEMA power cords instead of IEC C13 cords. Integrators planning a rack PDU installation with the EMI201-10 should confirm the facility circuit supports 120\/240V split-phase service and the L14-30P connector before finalizing electrical rough-in.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 NEMA 5-20R Outlets\u003c\/strong\u003e — A full set of standard 120V receptacles supports racks populated with commodity servers and network equipment using NEMA power cords.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120\/240V Split-Phase Input\u003c\/strong\u003e — Matches common data center and colocation electrical infrastructure without requiring 3-phase service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetered Load Monitoring\u003c\/strong\u003e — Local display plus Ethernet and RS-232 connectivity provide both on-site and remote visibility into input load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0U Vertical Mounting\u003c\/strong\u003e — The PDU installs along the rack frame, preserving rack unit space for active equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNEMA L14-30P Input Plug\u003c\/strong\u003e — A standard split-phase connector simplifies electrical planning in facilities with existing 120\/240V circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Listed Construction\u003c\/strong\u003e — Independent safety certification supports use in commercial data center and colocation environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Year Limited Warranty\u003c\/strong\u003e — Backed by Eaton's standard rack PDU warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eData center\u003c\/li\u003e\n\u003cli\u003eColocation cabinet\u003c\/li\u003e\n\u003cli\u003eServer room\u003c\/li\u003e\n\u003cli\u003eNetwork closet\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V AC, split-phase, 50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current\/Amperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Plug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA L14-30P, 10 ft cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Receptacles\/Outlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 x NEMA 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating (kW\/VA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.76 kW max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\/Form Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0U, vertical rack-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitoring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered (local display plus Ethernet\/RS-232 remote monitoring; no individual outlet switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 63.1 in H x 2.1 in W x 2.05 in D; 11.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-year limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat kind of equipment can connect to the EMI201-10's outlets?\u003c\/h3\u003e\n\u003cp\u003eAll 24 outlets are NEMA 5-20R receptacles, suited to servers, switches, and other 120V IT equipment that use standard NEMA power cords rather than IEC C13\/C19 connections.\u003c\/p\u003e\n\u003ch3\u003eWhat electrical circuit does this PDU require?\u003c\/h3\u003e\n\u003cp\u003eIt requires a 120\/240V split-phase circuit rated for 24A, terminated with a NEMA L14-30P receptacle. Confirm this matches your facility's available electrical service before ordering.\u003c\/p\u003e\n\u003ch3\u003eCan this PDU be monitored remotely?\u003c\/h3\u003e\n\u003cp\u003eYes. The EMI201-10 includes an Ethernet interface and RS-232 serial port for remote monitoring of input load alongside its local display.\u003c\/p\u003e\n\u003ch3\u003eDoes the EMI201-10 support individual outlet switching?\u003c\/h3\u003e\n\u003cp\u003eNo. This is a metered input model, reporting total load without per-outlet control. Eaton's switched or managed PDU models are available where outlet-level control is required.\u003c\/p\u003e\n\u003ch3\u003eHow is the EMI201-10 mounted in a rack cabinet?\u003c\/h3\u003e\n\u003cp\u003eIt mounts vertically in a 0U configuration along the rack frame, keeping all 24 outlets accessible without consuming horizontal rack unit space.\u003c\/p\u003e\n\u003ch3\u003eWhat warranty does this PDU carry?\u003c\/h3\u003e\n\u003cp\u003eThe EMI201-10 is covered by Eaton's standard 3-year limited warranty. Contact Eaton or Creation Networks for full terms.\u003c\/p\u003e\n\u003ch3\u003eCan Creation Networks help confirm this PDU fits my rack's equipment mix?\u003c\/h3\u003e\n\u003cp\u003eYes. Creation Networks can review your equipment list and available circuit type to confirm the EMI201-10's NEMA 5-20R outlet configuration matches your data center or colocation cabinet deployment.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47865657032940,"sku":"EMI201-10","price":1793.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMI201-10_0_00ab260b-126c-4889-81a8-5bbac561063d.jpg?v=1786644768","url":"https:\/\/creationnetworks.net\/products\/eaton-emi201-10-metered-input-rack-pdu","provider":"Creation Networks","version":"1.0","type":"link"}