{"product_id":"eaton-emi104-10-metered-input-rack-pdu","title":"Eaton EMI104-10 – 0U Vertical Metered Rack PDU 5.76kW","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Eaton EMI104-10 metered rack PDU is built for data center and server room installations that need reliable, monitored power distribution in a single-phase, 0U vertical form factor. As a metered rack PDU, it provides real-time load data at the unit so integrators and facilities staff can verify circuit loading during commissioning and ongoing operation. Common deployment scenarios include colocation cabinet buildouts, network closet upgrades, and server room retrofits where rack-mount power distribution with amperage visibility is a requirement. This unit is a straightforward fit for AV\/IT integrators standardizing on a single metered PDU platform across multiple rack elevations.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMI104-10_C.jpg?v=1782802228\" alt=\"Eaton EMI104-10 rack PDU\" style=\"max-width:100%;height:auto;\"\u003e\n\u003cp\u003eThe Eaton EMI104-10 is a single-phase, metered input rack PDU rated for 200-240V input at up to 24A, delivering a maximum of 5.76 kW to connected IT equipment. It mounts vertically in the rear channel of a server rack (0U), preserving horizontal rack unit space for servers, switches, and other active equipment. The unit provides 42 total outlets in a mix of IEC 60320 C13 and C19 receptacles, giving integrators flexibility to power servers, switches, storage arrays, and other equipment with standard C14 or C20 cords from a single distribution point. A local digital display shows aggregate input current and voltage, letting facilities and IT staff confirm the circuit is within safe operating limits without connecting to a network. For remote visibility, the EMI104-10 includes an Ethernet interface alongside an RS-232 serial port, supporting integration into existing data center monitoring and DCIM systems. This makes the EMI104-10 a practical choice for data center rack PDU installation projects where operators want metered load data without the added cost of outlet-level switching. The vertical 0U design and 66.5-inch length accommodate full-height, 42U-class server racks common in colocation cabinet and enterprise server room environments. Because it is a metered rather than switched unit, it suits environments where remote outlet control is not required but load visibility and capacity planning are priorities. The L6-30P input plug is a standard commercial-grade connector found in most data center and network closet electrical infrastructure, simplifying installation for licensed electricians. Integrators frequently pair this PDU with rack-mount UPS systems, KVM switches, and structured cabling to complete a rack-level power and connectivity deployment.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e42-Outlet Capacity\u003c\/strong\u003e — The combination of 36 C13 and 6 C19 receptacles supports a mix of servers, switches, and higher-draw equipment from a single rack PDU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal Digital Metering\u003c\/strong\u003e — An integrated display shows real-time input voltage and current so staff can verify load without remote tools.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0U Vertical Mounting\u003c\/strong\u003e — The PDU installs in the rear of the rack without consuming usable rack unit space needed for servers and network gear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet and Serial Connectivity\u003c\/strong\u003e — Built-in network and RS-232 interfaces allow remote monitoring integration with data center management platforms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200-240V, 24A Single-Phase Input\u003c\/strong\u003e — Matches standard commercial and data center electrical branch circuits for straightforward installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Listed Construction\u003c\/strong\u003e — Independent safety certification supports use in commercial data center and server room environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTAA Compliance\u003c\/strong\u003e — Meets Trade Agreements Act requirements, making the unit eligible for government and federal contract procurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Year Limited Warranty\u003c\/strong\u003e — Backed by Eaton's standard rack PDU warranty for long-term deployment confidence.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eData center\u003c\/li\u003e\n\u003cli\u003eColocation cabinet\u003c\/li\u003e\n\u003cli\u003eServer room\u003c\/li\u003e\n\u003cli\u003eNetwork closet\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-240V AC, single-phase, 50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current\/Amperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Plug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA L6-30P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Receptacles\/Outlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42 total: (36) IEC 60320 C13, (6) IEC 60320 C19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating (kW\/VA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.76 kW max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\/Form Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0U, vertical rack-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitoring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetered (local digital display plus Ethernet\/RS-232 remote monitoring; no individual outlet switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66.5 in H x 2.1 in W x 2.05 in D; 15.54 lb; 10 ft cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, TAA Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-year limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eIs the EMI104-10 compatible with standard 42U server racks?\u003c\/h3\u003e\n\u003cp\u003eYes. The 0U vertical form factor and 66.5-inch length are designed to fit standard 42U-class server racks, mounting in the rear vertical channel alongside cable management.\u003c\/p\u003e\n\u003ch3\u003eDoes this PDU require a licensed electrician for installation?\u003c\/h3\u003e\n\u003cp\u003eThe EMI104-10 uses a standard NEMA L6-30P plug, so it can be connected to an existing compatible receptacle. Wiring the branch circuit itself should be performed by a licensed electrician in accordance with local code.\u003c\/p\u003e\n\u003ch3\u003eCan the EMI104-10 be monitored remotely through a DCIM or network management system?\u003c\/h3\u003e\n\u003cp\u003eYes. The unit includes an Ethernet interface and RS-232 serial port, allowing integration with common data center infrastructure management and monitoring platforms.\u003c\/p\u003e\n\u003ch3\u003eDoes this PDU support remote outlet switching or rebooting individual devices?\u003c\/h3\u003e\n\u003cp\u003eNo. The EMI104-10 is a metered PDU, meaning it reports load data but does not provide individual outlet on\/off switching. Customers who need remote outlet control should look at Eaton's switched or managed rack PDU models.\u003c\/p\u003e\n\u003ch3\u003eWhat warranty does the EMI104-10 carry?\u003c\/h3\u003e\n\u003cp\u003eThe EMI104-10 is covered by Eaton's standard 3-year limited warranty. Contact Eaton or Creation Networks for full warranty terms and service options.\u003c\/p\u003e\n\u003ch3\u003eCan this PDU be used with a rack-mount UPS in the same cabinet?\u003c\/h3\u003e\n\u003cp\u003eYes. The EMI104-10 is commonly deployed downstream of a rack-mount UPS to distribute conditioned or backup power to servers, switches, and other rack-mounted equipment.\u003c\/p\u003e\n\u003ch3\u003eWhat support is available if I have questions before purchasing?\u003c\/h3\u003e\n\u003cp\u003eCreation Networks provides pre-sale technical guidance for Eaton rack PDU selection, including help matching input voltage, amperage, and outlet configuration to your rack's electrical infrastructure.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47865658081516,"sku":"EMI104-10","price":1305.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMI104-10_C.jpg?v=1782802228","url":"https:\/\/creationnetworks.net\/products\/eaton-emi104-10-metered-input-rack-pdu","provider":"Creation Networks","version":"1.0","type":"link"}