{"product_id":"eaton-emat09-10-managed-rack-pdu","title":"Eaton EMAT09-10 – 1U Managed Rack PDU, 8 Outlets","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton EMAT09-10 is a compact 1U managed rack PDU designed for network closets, AV equipment racks, and lighter-load server rooms that need outlet-level power monitoring without consuming multiple rack units. Rated for 120V, 12A input and 1.44 kW maximum output across 8 NEMA 5-15R outlets, it is sized for edge closets and small IT rooms rather than high-density data center rows. Its 1U managed rack PDU footprint and RJ-45 network monitoring make it a practical choice for integrators standardizing remote power control across distributed network closets and commercial AV installations. The unit's low-voltage single-phase input also simplifies installation in facilities without dedicated three-phase circuits.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMAT09-10_C.jpg?v=1782802348\" alt=\"Eaton EMAT09-10 rack PDU\" style=\"max-width:100%;height:auto;\"\u003e\u003c\/p\u003e\u003cp\u003eThe EMAT09-10 is part of Eaton's ePDU Managed platform, built for organizations that need remote visibility into smaller IT and AV equipment racks distributed across a building or campus. Input is a standard 120V, 12A NEMA 5-20P plug, feeding 8 NEMA 5-15R outlets for a maximum load of 1.44 kW, which comfortably supports network switches, small servers, wireless controllers, and AV signal processing equipment. Its 1U rack-mount, horizontal form factor installs in a single rack unit, an important consideration in shallow wall-mount cabinets and AV racks where space is limited. Remote management is delivered over an RJ-45 network connection, giving IT and AV support staff outlet-level monitoring and control from a central location rather than requiring a technician to visit each closet or rack. This is particularly useful for organizations managing power to distributed network closets, branch offices, or AV racks in commercial meeting spaces, where a technician dispatch for a simple power cycle is costly and slow. Because the EMAT09-10 draws from a standard 120V circuit, it can be installed in facilities without dedicated 208V or three-phase power, which is common in older buildings and smaller commercial spaces. The unit's compact depth also makes it suitable for shallow AV racks used in broadcast and presentation environments, where deeper 2U-or-larger PDUs may not fit. Facilities and AV integrators deploying a standardized remote-power strategy across multiple locations can use the EMAT09-10 as the baseline unit for lower-density racks, reserving higher-capacity PDUs for core data center rows.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1U Rack-Mount Form Factor\u003c\/strong\u003e — Occupies a single rack unit, preserving space in compact network closets and AV racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Outlet Monitoring\u003c\/strong\u003e — Provides network-based visibility into power draw and outlet status without an on-site visit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard 120V Input\u003c\/strong\u003e — Installs on common building circuits without requiring dedicated 208V or three-phase power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 NEMA 5-15R Outlets\u003c\/strong\u003e — Supports switches, small servers, and AV equipment commonly found in edge and branch installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRJ-45 Network Interface\u003c\/strong\u003e — Integrates with existing IT network infrastructure for centralized PDU management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Depth\u003c\/strong\u003e — Fits shallow AV and network racks where larger PDUs will not physically install.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial-Grade Reliability\u003c\/strong\u003e — Built for continuous operation in unattended network closets and equipment rooms.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eServer room\u003c\/li\u003e\n\u003cli\u003eNetwork closet\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120V, 50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\/Amperage\u003c\/td\u003e\n\u003ctd\u003e12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Plug\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-20P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\/Outlets\u003c\/td\u003e\n\u003ctd\u003e8x NEMA 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e1.44 kW max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\/Form Factor\u003c\/td\u003e\n\u003ctd\u003e1U rack-mount, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring Type\u003c\/td\u003e\n\u003ctd\u003eManaged — RJ-45 network monitoring, outlet-level control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 19\" W x 1.6\" H x 8\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL Listed, RoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWill the EMAT09-10 fit in a shallow AV or network rack?\u003c\/h3\u003e\u003cp\u003eYes. At approximately 8 inches of depth and 1U tall, it is sized to fit shallow AV and network racks where larger 2U or 0U vertical PDUs will not physically install.\u003c\/p\u003e\u003ch3\u003eDoes this PDU require a special electrical circuit?\u003c\/h3\u003e\u003cp\u003eNo. It runs on a standard 120V, 12A circuit through a NEMA 5-20P plug, making it compatible with typical commercial building power without dedicated 208V service.\u003c\/p\u003e\u003ch3\u003eCan I monitor outlet-level power draw remotely?\u003c\/h3\u003e\u003cp\u003eYes. The EMAT09-10 provides network-based, outlet-level monitoring over its RJ-45 interface, so IT staff can check load and status without visiting the rack.\u003c\/p\u003e\u003ch3\u003eIs the EMAT09-10 suitable for AV equipment racks in meeting rooms?\u003c\/h3\u003e\u003cp\u003eYes. Its compact 1U profile and standard 120V input make it a practical fit for AV racks in commercial meeting spaces and presentation rooms.\u003c\/p\u003e\u003ch3\u003eDoes it integrate with existing network monitoring tools?\u003c\/h3\u003e\u003cp\u003eIts RJ-45 network interface is designed to integrate with standard IT monitoring platforms, allowing centralized visibility alongside other managed PDUs.\u003c\/p\u003e\u003ch3\u003eWhat is the warranty on the EMAT09-10?\u003c\/h3\u003e\u003cp\u003eThe EMAT09-10 carries Eaton's 3-year limited warranty. Contact Eaton or Creation Networks to confirm current terms.\u003c\/p\u003e\u003ch3\u003eCan Creation Networks help select the right PDU for a distributed network closet rollout?\u003c\/h3\u003e\u003cp\u003eYes. Creation Networks can help integrators compare the EMAT09-10 against higher-capacity managed PDUs to match each closet's actual load requirements.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47865663946988,"sku":"EMAT09-10","price":957.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMAT09-10_C.jpg?v=1782802348","url":"https:\/\/creationnetworks.net\/products\/eaton-emat09-10-managed-rack-pdu","provider":"Creation Networks","version":"1.0","type":"link"}