{"product_id":"eaton-9px3k3untf5g2-9px-g2-3000va-3000w-208-120v-online-double-conversion-ups","title":"Eaton 9PX3K3UNTF5G2 – 3000VA Online Double-Conversion UPS","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton 9PX3K3UNTF5G2 is a 3000VA\/3000W online double-conversion UPS designed as a 3000VA rack-mount UPS for distributed IT and edge network installations, including centralized AV racks in commercial buildings. Its online double-conversion UPS for AV rack topology keeps connected servers, switches, and AV processors on continuously regulated power rather than switching to battery only during an outage. For integrators managing a commercial UPS battery backup installation across multiple rooms, this unit's 208V input and flexible hardwire or L6-30P connection options make it adaptable to varied electrical infrastructure. It fits the same 9PX G2 platform used in larger data closets, giving a mid-capacity option as a 3000W UPS for network rack deployments.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/9px3k3untf5g2.jpg?v=1786678651\" alt=\"Eaton 9PX3K3UNTF5G2 3000VA rack-mount double-conversion UPS\" style=\"max-width:100%;height:auto;\"\u003e\u003cp\u003eThis 6U rack\/tower UPS supports both 208V and 120V AV or IT loads through a mix of 5-20R, L6-20R, and L6-30R outlets, plus support for a direct hardwire connection where local code or facility standards require it. That flexibility makes it well suited for a 208V rack UPS with hardwire input requirement in commercial buildings where an electrician has already run dedicated circuits to the equipment rack. Like its larger 9PX G2 siblings, it uses true online double-conversion topology with a rated 96 percent efficiency at maximum load, reducing both the electrical cost and heat load inside an enclosed AV or IT rack. At full 3000W load it provides roughly 7.5 minutes of battery runtime, extending to about 18.5 minutes at half load, giving facilities staff or connected shutdown scripts enough time to respond to an extended outage. A NETWORK-M3 Gigabit card is included standard, supporting SNMP monitoring so this unit can be tracked alongside other network infrastructure from a central dashboard. As a rack UPS for conference room AV head-end applications, its 3000VA capacity comfortably covers a rack of matrix switchers, DSPs, and control processors without oversizing the investment.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnline Double-Conversion Topology\u003c\/strong\u003e — Continuously regenerates output power for zero-transfer-time protection against AV and IT equipment brownouts and surges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3000VA\/3000W Capacity\u003c\/strong\u003e — Sized for a typical AV or IT equipment rack without the cost or footprint of a larger 5kVA-plus unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardwire or L6-30P Input\u003c\/strong\u003e — Supports either a direct hardwired connection or a standard twist-lock plug, adapting to whatever circuit the facility has installed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixed Voltage Outlets\u003c\/strong\u003e — 5-20R, L6-20R, and L6-30R receptacles allow both 120V AV gear and 208V IT equipment to run from one UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded NETWORK-M3 Card\u003c\/strong\u003e — Enables SNMP and web-based remote monitoring for facilities and IT teams.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e96 Percent Efficiency\u003c\/strong\u003e — Lowers heat output and operating cost inside enclosed AV or data closet racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Year Limited Warranty\u003c\/strong\u003e — Covers parts, electronics, and batteries under Eaton's standard commercial terms.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCommercial meeting space AV racks centralizing switching, DSP, and control equipment\u003c\/li\u003e\n\u003cli\u003eGovernment space equipment rooms requiring hardwired UPS installation per facility code\u003c\/li\u003e\n\u003cli\u003eTraining room and multi-purpose room AV head-ends supporting several connected spaces\u003c\/li\u003e\n\u003cli\u003eAuditorium equipment racks needing mid-capacity, continuously regulated power\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;min-width:480px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;border-bottom:1px solid #ccc;padding:6px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align:left;border-bottom:1px solid #ccc;padding:6px;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eCapacity\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e3000 VA \/ 3000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eTopology\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eOnline double-conversion, true sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eInput Voltage \/ Plug\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e208V default (200\/208\/220\/230\/240V), L6-30P and hardwire input, 10 ft cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e120\/240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e18x 5-20R, 2x L6-20R, 1x L6-30R, plus hardwire support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eRuntime (Full Load \/ Half Load)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e7.5 min \/ 18.5 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eUp to 96% at max load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e10.2\" x 17.3\" x 27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e203 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e6U rack\/tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:6px;\"\u003e3-year limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eCan this UPS be hardwired instead of plugged in?\u003c\/h3\u003e\u003cp\u003eYes, the 9PX3K3UNTF5G2 supports either a direct hardwire connection or a standard L6-30P plug, so it can match whatever circuit configuration your electrician has installed.\u003c\/p\u003e\u003ch3\u003eWill this UPS fit a standard 19-inch AV rack?\u003c\/h3\u003e\u003cp\u003eYes, it is a 6U rack\/tower unit designed for standard 19-inch racks and can also be operated as a freestanding tower if needed.\u003c\/p\u003e\u003ch3\u003eHow does remote monitoring work with this unit?\u003c\/h3\u003e\u003cp\u003eThe included NETWORK-M3 card provides SNMP and web-based monitoring, allowing facilities or IT staff to view load, alarms, and battery health remotely.\u003c\/p\u003e\u003ch3\u003eWhat is the expected runtime during a power outage?\u003c\/h3\u003e\u003cp\u003eAt full 3000W load expect approximately 7.5 minutes of runtime, extending to about 18.5 minutes at half load.\u003c\/p\u003e\u003ch3\u003eDoes this unit support both 120V and 208V equipment simultaneously?\u003c\/h3\u003e\u003cp\u003eYes, its mix of 5-20R, L6-20R, and L6-30R receptacles allows both 120V AV devices and 208V IT equipment to draw power from the same UPS.\u003c\/p\u003e\u003ch3\u003eWhat warranty coverage is included?\u003c\/h3\u003e\u003cp\u003eEaton provides a 3-year limited warranty covering parts, electronics, and batteries on this model.\u003c\/p\u003e\u003ch3\u003eCan Creation Networks assist with sizing this UPS to my AV rack's total load?\u003c\/h3\u003e\u003cp\u003eYes, our team can calculate your connected equipment's power draw and confirm the 9PX3K3UNTF5G2 provides sufficient capacity and runtime, or suggest an alternative from the 9PX G2 lineup.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159973933292,"sku":"9PX3K3UNTF5G2","price":5876.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/9px3k3untf5g2.jpg?v=1786678651","url":"https:\/\/creationnetworks.net\/products\/eaton-9px3k3untf5g2-9px-g2-3000va-3000w-208-120v-online-double-conversion-ups","provider":"Creation Networks","version":"1.0","type":"link"}