{"product_id":"eaton-9px11ktf5g2-9px-g2-11000va-11000w-208-120v-online-double-conversion-ups","title":"Eaton 9PX11KTF5G2 – 11000VA Rack-Mount Online UPS","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton 9PX11KTF5G2 is an 11000VA\/11000W, 208\/120V online double-conversion UPS designed for large commercial AV racks, broadcast production rooms, and consolidated data closets. As an 11000VA rack-mount online UPS, it is engineered to power an entire equipment rack or several racks worth of switching, networking, and video processing gear without interruption. It is well suited as a double-conversion UPS for AV rack deployments where multiple 5-20R and L6-30R devices need clean, regulated power, and it functions as a large-capacity UPS for broadcast studio or auditorium environments that draw significant continuous load.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/9px11ktf5g2.jpg?v=1786678669\" alt=\"Eaton 9PX11KTF5G2 11000VA rack-mount online double-conversion UPS\" style=\"max-width:100%;height:auto;\"\u003e\u003cp\u003ePart of Eaton's 9PX G2 lineup, the 9PX11KTF5G2 provides true online double-conversion protection, meaning connected loads are always running from regenerated, isolated power rather than switched utility power, eliminating transfer-time gaps entirely. This matters for a rack-mount UPS for data closet or broadcast environments where even a momentary interruption can drop a live feed, reboot a video processor, or corrupt an in-progress recording. The unit is a 7U rack\/tower chassis with hardwired input and a mix of (3) L6-30R and (18) 5-20R hardwired output receptacles, giving integrators flexibility to power both high-draw equipment and a large number of standard IT\/AV devices from one UPS. Internal sealed lead-acid batteries are hot-swappable, and the system is expandable with up to 12 external battery modules for facilities that need substantially longer ride-through than the roughly 74 minutes available from internal batteries at light load. This scale of 208\/120V online UPS system is typically specified for larger training rooms, government facilities, houses of worship with sanctuary AV\/broadcast systems, and multi-room commercial buildings where a single centralized UPS feeds distribution to several downstream racks rather than one small room.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue Online Double-Conversion\u003c\/strong\u003e — Continuously regenerates AC output so there is no transfer delay when utility power is lost, protecting sensitive AV and broadcast equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e11000VA\/11000W Capacity\u003c\/strong\u003e — Supports large, densely populated equipment racks or multiple consolidated racks from a single UPS system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixed Outlet Configuration\u003c\/strong\u003e — (3) L6-30R and (18) 5-20R hardwired outlets provide flexibility for both high-current and standard-current commercial devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable Batteries\u003c\/strong\u003e — Internal batteries can be serviced without powering down connected equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpandable to 12 External Battery Modules\u003c\/strong\u003e — Allows integrators to scale runtime to match facility-specific backup requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Efficiency Mode\u003c\/strong\u003e — Up to 99% efficiency reduces heat generation and operating costs in the equipment rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Year Manufacturer Warranty\u003c\/strong\u003e — Backed by Eaton's standard commercial coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003cli\u003eHouse of worship\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;min-width:480px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;border-bottom:1px solid #ccc;padding:6px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align:left;border-bottom:1px solid #ccc;padding:6px;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003ePower Rating\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e11000VA \/ 11000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e200\/208\/220\/230\/240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eInput Voltage Range (Full Load)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e176-276V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eOutput Regulation\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e±1% steady-state\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eInput Connection\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eHardwired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eOutput Connections\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e(3) L6-30R, (18) 5-20R hardwired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e12 (7U) x 17.3 x 32.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e315 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e97% online mode \/ 99% high-efficiency mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eBattery Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eInternal sealed lead-acid, hot-swappable, expandable up to 12 EBMs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eRuntime (Internal Battery, ~10% Load)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eApprox. 74.3 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border-bottom:1px solid #eee;\"\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eIs this UPS sized for a single small conference room?\u003c\/h3\u003e\u003cp\u003eNo, 11000VA is typically sized for large consolidated racks, master AV\/broadcast rooms, or multiple downstream racks rather than a single small conference room; Creation Networks can help confirm proper sizing.\u003c\/p\u003e\u003ch3\u003eCan it power both high-draw and standard equipment simultaneously?\u003c\/h3\u003e\u003cp\u003eYes, the mixed outlet set of L6-30R and 5-20R receptacles allows high-current devices and standard IT\/AV equipment to be powered from the same UPS.\u003c\/p\u003e\u003ch3\u003eDoes installation require an electrician?\u003c\/h3\u003e\u003cp\u003eYes, both input and output are hardwired, so installation must be performed by a licensed electrician per local code.\u003c\/p\u003e\u003ch3\u003eHow is runtime extended beyond the internal battery?\u003c\/h3\u003e\u003cp\u003eThe 9PX11KTF5G2 supports up to 12 external battery modules, allowing integrators to extend backup time well beyond the roughly 74 minutes provided by internal batteries at light load.\u003c\/p\u003e\u003ch3\u003eCan this UPS integrate with a building management or monitoring system?\u003c\/h3\u003e\u003cp\u003eYes, optional network management cards enable SNMP monitoring and remote alerts, which integrates with facility monitoring for larger commercial deployments.\u003c\/p\u003e\u003ch3\u003eWhat warranty coverage applies?\u003c\/h3\u003e\u003cp\u003eThe unit carries Eaton's standard 3-year manufacturer warranty; contact Creation Networks for extended coverage options.\u003c\/p\u003e\u003ch3\u003eDoes Eaton offer a compatible power distribution accessory for downstream AV racks?\u003c\/h3\u003e\u003cp\u003eEaton's 9PX G2 PowerPass distribution modules are designed for the 3kVA-6kVA UPS range rather than this 11kVA model; contact Creation Networks for the correct downstream PDU recommendation for this UPS.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159974260972,"sku":"9PX11KTF5G2","price":12178.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/9px11ktf5g2.jpg?v=1786678669","url":"https:\/\/creationnetworks.net\/products\/eaton-9px11ktf5g2-9px-g2-11000va-11000w-208-120v-online-double-conversion-ups","provider":"Creation Networks","version":"1.0","type":"link"}