{"product_id":"eaton-9px11kmg2-9px-g2-11000va-11000w-208v-online-double-conversion-ups","title":"Eaton 9PX11KMG2 – 11kVA 208V Online Double-Conversion UPS","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton 9PX11KMG2 is an 11kVA\/11kW, 208V online double-conversion UPS engineered for distributed IT and edge network deployments where zero-transfer-time power protection is non-negotiable. This 11kVA online double-conversion UPS is built for data closets, network operations centers, and commercial facilities running mission-critical IT and AV infrastructure, offering a genuine 208V UPS for edge network deployment scenarios. As a commercial UPS battery backup installation for higher-capacity environments, it protects against blackouts, brownouts, surges, and line noise that can destroy data or damage equipment.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/9px11kmg2.jpg?v=1786678631\" alt=\"Eaton 9PX11KMG2 11kVA 208V online double-conversion UPS\" style=\"max-width:100%;height:auto;\"\u003e\u003cp\u003eThe 9PX11KMG2 uses true online double-conversion topology, continuously converting incoming AC to DC and back to a clean sine wave output, so connected equipment never experiences a transfer event when utility power fails. Housed in a 4U rack\/tower chassis, it fits into data closets and IT racks that also house networking, storage, and AV distribution equipment for larger commercial deployments. A maintenance bypass switch (MBP) allows technicians to service the UPS without powering down connected loads, which reduces planned downtime for facilities running continuous operations. Four hardwired L6-30R outlet connections support higher-density equipment racks common in edge computing and distributed network installations. The unit ships with a NETWORK-M3 Gigabit card for remote monitoring and management, giving IT teams visibility into load, battery health, and alarms from a central console. At up to 97% efficiency, it reduces both operating costs and heat load in the equipment room, and its hot-swappable internal batteries with ABM+ analytics extend battery service life through smarter charging. This high-capacity UPS for distributed IT networks is designed for mission-critical applications where even momentary power interruptions are unacceptable.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnline Double-Conversion Topology\u003c\/strong\u003e — Delivers zero transfer time by continuously regenerating clean AC output, eliminating switchover events entirely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Bypass Switch\u003c\/strong\u003e — Enables service and battery replacement without interrupting power to connected equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNETWORK-M3 Gigabit Card Included\u003c\/strong\u003e — Provides remote monitoring and management for IT teams overseeing distributed sites.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e97% Efficiency at Full Load\u003c\/strong\u003e — Lowers operating costs and reduces heat generation in equipment rooms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4U Rack\/Tower Form Factor\u003c\/strong\u003e — Fits into standard IT and data closet racks or operates as a standalone tower unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour Hardwired L6-30R Outlets\u003c\/strong\u003e — Supports high-density equipment loads typical of edge and distributed IT deployments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable Batteries with ABM+ Technology\u003c\/strong\u003e — Extends battery life through advanced charging analytics and allows service without downtime.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpandable Battery Modules\u003c\/strong\u003e — Supports up to 12 optional battery modules for extended runtime requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eData closets and network operations centers requiring zero-transfer-time power protection\u003c\/li\u003e\n\u003cli\u003eEdge computing and distributed IT network deployments\u003c\/li\u003e\n\u003cli\u003eGovernment and enterprise facilities running mission-critical IT infrastructure\u003c\/li\u003e\n\u003cli\u003eMulti-site commercial buildouts standardizing on 208V power distribution\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;min-width:480px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;border:1px solid #ccc;padding:6px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"text-align:left;border:1px solid #ccc;padding:6px;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eCapacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e11,000 VA \/ 11,000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eTopology\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eOnline \/ double-conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e208V default (200\/208\/220\/230\/240V selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e208V default (200\/208\/220\/230\/240\/250V selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e±1% steady-state\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eOutput Power Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e97% at maximum load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eOutlets\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e(4) L6-30R, hardwired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eNoise Level\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e≤54 dB at 100% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e4U rack\/tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e32.6 in x 17.3 in x 6.8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e188.7 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ccc;padding:6px;\"\u003e3-year factory warranty (parts, electronics, batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eCan this UPS be serviced without powering down connected equipment?\u003c\/h3\u003e\u003cp\u003eYes, the built-in maintenance bypass switch allows technicians to route power around the UPS during service or battery replacement without interrupting connected loads.\u003c\/p\u003e\u003ch3\u003eWill this unit fit in a standard IT or data closet rack?\u003c\/h3\u003e\u003cp\u003eYes, it is built in a 4U rack\/tower chassis compatible with standard 19-inch racks, or it can be deployed as a freestanding tower.\u003c\/p\u003e\u003ch3\u003eHow is this UPS monitored remotely?\u003c\/h3\u003e\u003cp\u003eIt ships with a NETWORK-M3 Gigabit network card that provides SNMP-based remote monitoring, alerting, and management integration.\u003c\/p\u003e\u003ch3\u003eDoes the output require hardwiring, or does it use standard outlets?\u003c\/h3\u003e\u003cp\u003eOutput connects via four hardwired L6-30R receptacle connections, which should be installed by a licensed electrician as part of the commercial power distribution plan.\u003c\/p\u003e\u003ch3\u003eWhat warranty coverage comes with this unit?\u003c\/h3\u003e\u003cp\u003eEaton provides a 3-year factory warranty covering parts, electronics, and batteries.\u003c\/p\u003e\u003ch3\u003eCan runtime be extended beyond the internal batteries?\u003c\/h3\u003e\u003cp\u003eYes, the 9PX11KMG2 supports up to 12 optional battery modules for facilities requiring extended runtime during longer outages.\u003c\/p\u003e\u003ch3\u003eIs this UPS suitable for edge computing or distributed network sites?\u003c\/h3\u003e\u003cp\u003eYes, its double-conversion topology, hardwired outlets, and remote monitoring capability make it well suited for edge and distributed IT deployments across multiple commercial sites.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48159973376236,"sku":"9PX11KMG2","price":11106.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/9px11kmg2.jpg?v=1786678631","url":"https:\/\/creationnetworks.net\/products\/eaton-9px11kmg2-9px-g2-11000va-11000w-208v-online-double-conversion-ups","provider":"Creation Networks","version":"1.0","type":"link"}