{"product_id":"crestron-clt-1fan4","title":"Crestron CLT-1FAN4 – Terminal Block Replacement for CLX-1FAN4 Fan Controller","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Crestron CLT-1FAN4 is the field-wiring terminal block designed for use with the CLX-1FAN4 four-channel fan speed control module in CAEN-series automation enclosures. It provides the removable load-side wiring connection point for fan circuits, allowing integrators to pre-wire and test the terminal block independently of the module itself, and to replace or service wiring without disturbing the installed CLX-1FAN4. This is a replacement or spare terminal block, not a standalone control device.\u003c\/p\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe CLT-1FAN4 mates directly with the CLX-1FAN4 module, which controls up to four fan speed circuits with four preset speeds plus off per channel. The terminal block provides clearly labeled connection points for each fan circuit's line, neutral, and fan speed tap wiring. Electrical bypass jumpers on each channel allow individual circuits to be tested or bypassed during installation and commissioning, reducing troubleshooting time and protecting the module electronics. The terminal block mounts within any CAEN-series enclosure alongside the CLX-1FAN4 module. Having spare CLT-1FAN4 terminal blocks on hand allows pre-wiring at rough-in stage before the control modules are installed, which is standard practice on new construction projects.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eReplacement field-wiring terminal block for the CLX-1FAN4 four-channel fan controller\u003c\/li\u003e\n\u003cli\u003eSupports 4 fan speed channels (4 preset speeds + off per channel)\u003c\/li\u003e\n\u003cli\u003eElectrical bypass jumpers on each channel for circuit testing and module protection\u003c\/li\u003e\n\u003cli\u003eRemovable design allows pre-wiring at rough-in prior to module installation\u003c\/li\u003e\n\u003cli\u003eClearly labeled terminals for line, neutral, and fan speed tap wiring\u003c\/li\u003e\n\u003cli\u003eCompatible with all CAEN-series automation enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eReplacement terminal blocks for existing CLX-1FAN4 installations in CAEN enclosures\u003c\/li\u003e\n\u003cli\u003ePre-wiring at rough-in stage for fan circuits in new residential construction\u003c\/li\u003e\n\u003cli\u003eSpare parts inventory for Crestron residential and light commercial installers\u003c\/li\u003e\n\u003cli\u003eService calls requiring re-wiring of fan control circuits without module removal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e CLT-1FAN4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Module:\u003c\/strong\u003e CLX-1FAN4 (4-Channel Fan Speed Control Module)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFan Channels:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeeds per Channel:\u003c\/strong\u003e 4 preset speeds + off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 2A per channel, 8A total\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 120 VAC, 60 Hz, single-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Network:\u003c\/strong\u003e Cresnet (via CLX-1FAN4 module)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 32° to 104°F (0° to 40°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 0%–90% RH non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e CAEN-series enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the CLT-1FAN4 be used without the CLX-1FAN4 module installed?\u003c\/strong\u003e\u003cbr\u003eA: The terminal block can be wired and installed in the enclosure independently during rough-in, but fan control functions are only active when the CLX-1FAN4 module is properly seated. The bypass jumpers on each channel can be engaged to allow fan circuits to operate in bypass mode during pre-commissioning testing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the CLT-1FAN4 specific to the CLX-1FAN4, or does it work with other CLX modules?\u003c\/strong\u003e\u003cbr\u003eA: The CLT-1FAN4 is specific to the CLX-1FAN4 fan speed control module. Other CLX modules use their own corresponding CLT terminal blocks (e.g., CLT-1DIMU4 for CLX-1DIMU4, CLT-1MC4 for CLX-1MC4).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Where can I find the wiring diagram for the CLT-1FAN4?\u003c\/strong\u003e\u003cbr\u003eA: Wiring diagrams are included in the CLX-1FAN4 installation guide, available in the product documentation section at creationnetworks.net or from Crestron technical support.\u003c\/p\u003e","brand":"Crestron","offers":[{"title":"Default Title","offer_id":47759569322220,"sku":"CLT-1FAN4","price":90.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/master_photo_a-clt-1fan4.png?v=1781794165","url":"https:\/\/creationnetworks.net\/products\/crestron-clt-1fan4","provider":"Creation Networks","version":"1.0","type":"link"}