{"product_id":"apc-smart-ups-srt5krmxlt-5000va-rm-208v","title":"APC Smart-UPS SRT5KRMXLT 5000VA RM 208V","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe APC Smart-UPS SRT5KRMXLT is a 5000VA \/ 4500W double-conversion on-line UPS in a 3U rackmount chassis with 208V input and output, designed for high-capacity commercial AV, data center, and enterprise IT rack deployments requiring on-line power protection at the 208V distribution level. This unit delivers zero-transfer-time power protection with scalable runtime through external APC SRT battery packs, and accepts optional NMC for enterprise SNMP monitoring. The 208V design is appropriate for dedicated power circuits in commercial spaces with 208V distribution panels common in North American commercial buildings.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe SRT5KRMXLT addresses commercial AV and data center deployments operating on 208V power distribution — common in commercial construction where 208V 3-phase power feeds dedicated equipment circuits in server rooms, broadcast facilities, and command centers. At 5000VA \/ 4500W, this unit protects high-density rack configurations including video wall controllers, broadcast routers, multiple servers, and large-scale AV distribution systems that exceed the capacity of 120V UPS units. Double-conversion on-line topology provides complete galvanic isolation and zero transfer time, critical for broadcast-grade AV equipment sensitive to power disturbances. The 3U chassis installs in standard 19-inch racks. External APC SRT battery packs extend runtime, and SmartSlot accepts optional NMC for enterprise monitoring. Two L6-20R and two L6-30R NEMA output receptacles serve equipment with 208V plug configurations.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5000VA \/ 4500W Capacity\u003c\/strong\u003e — High-capacity 208V on-line protection for large commercial AV and data center racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble-Conversion On-Line Topology\u003c\/strong\u003e — Zero transfer time and complete 208V input\/output isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e208V Input\/Output\u003c\/strong\u003e — Designed for commercial 208V power distribution circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3U Rackmount\u003c\/strong\u003e — Standard 19-inch installation with rail kit included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScalable Runtime\u003c\/strong\u003e — External APC SRT battery packs for extended outage protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmartSlot\u003c\/strong\u003e — Accepts optional NMC for SNMP and enterprise monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e208V NEMA Receptacles\u003c\/strong\u003e — L6-20R and L6-30R outputs for 208V equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBroadcast studio and production rack power at 208V\u003c\/li\u003e\n\u003cli\u003eCommand and control center 208V power infrastructure\u003c\/li\u003e\n\u003cli\u003eData center and server room high-capacity UPS at 208V\u003c\/li\u003e\n\u003cli\u003eLarge commercial AV installations on 208V circuits\u003c\/li\u003e\n\u003cli\u003eVideo wall and large-format display processor racks\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;\"\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:8px;border:1px solid #ddd;text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSRT5KRMXLT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eCapacity\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e5000VA \/ 4500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eTopology\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eDouble-Conversion On-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003ePure Sine Wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e3U Rackmount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e2x L6-20R, 2x L6-30R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eSmartSlot\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eYes (optional NMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eExternal Battery\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eCompatible with APC SRT 192V battery packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:8px;border:1px solid #ddd;\"\u003e2 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003e\u003cstrong\u003eDoes my facility need 208V distribution to use the SRT5KRMXLT?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes. The SRT5KRMXLT requires a 208V input circuit. Confirm with your electrical contractor that 208V distribution is available at the intended rack location before specification.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat external battery packs are compatible?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThe SRT5KRMXLT uses APC SRT 192V battery packs (such as the SRT192RMBP) for extended runtime. Contact Creation Networks for compatible battery pack options and runtime calculations.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eIs SNMP monitoring available?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes, with an optional APC network management card installed in the SmartSlot. The SRT5KRMXLT does not include an NMC by default.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eCan this UPS serve a mixed AV and IT rack at 208V?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes. The SRT5KRMXLT is suitable for mixed commercial AV and IT equipment racks operating on 208V circuits, including servers, AV processors, and managed switches with 208V power supplies.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"APC","offers":[{"title":"Default Title","offer_id":47713898430700,"sku":"SRT5KRMXLT","price":11250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/files_d234acdf-1a0f-4e0e-b0da-cafbfedfe072.jpg?v=1780780275","url":"https:\/\/creationnetworks.net\/products\/apc-smart-ups-srt5krmxlt-5000va-rm-208v","provider":"Creation Networks","version":"1.0","type":"link"}