{"title":"SURGEX - The Best Surge Protectors, Power Conditioners","description":"\u003ch1\u003eSurgeX Power Protection and Conditioning Solutions\u003c\/h1\u003e\u003cp\u003eSurgeX manufactures advanced power protection, surge elimination, and power conditioning products engineered for professional AV systems. SurgeX safeguards sensitive AV equipment against surges, brownouts, and power-line noise. Creation Networks stocks the current catalog for U.S. integrators. For SKU selection and pricing, contact us through \u003ca href=\"https:\/\/creationnetworks.net\/pages\/contact\"\u003ecreationnetworks.net\u003c\/a\u003e.\u003c\/p\u003e\u003ch2\u003eProduct Families\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDefender Series Surge Elimination\u003c\/strong\u003e — surge-elimination racks for AV head-ends.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurgeX Squid\u003c\/strong\u003e — IP-controllable surge protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Stage Protection Rack Units\u003c\/strong\u003e — rack-mount power conditioners.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy and Power Monitoring\u003c\/strong\u003e — networked power monitoring solutions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSequencer \/ Sequencing Solutions\u003c\/strong\u003e — power sequencing for rack power-up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessories\u003c\/strong\u003e — replacement components and rack hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHouses of worship with broadcast and streaming racks\u003c\/li\u003e\n\u003cli\u003ePerforming arts and theaters\u003c\/li\u003e\n\u003cli\u003eSchools and university A\/V head-end rooms\u003c\/li\u003e\n\u003cli\u003eCorporate AV head-end rooms\u003c\/li\u003e\n\u003cli\u003eBroadcast studios and post-production racks\u003c\/li\u003e\n\u003cli\u003eTouring sound rentals and live event production\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eProject Support\u003c\/h2\u003e\u003cp\u003eFor SKU selection or quotes, contact us through our \u003ca href=\"https:\/\/creationnetworks.net\/pages\/contact\"\u003econtact page\u003c\/a\u003e or visit \u003ca href=\"https:\/\/creationnetworks.net\"\u003ecreationnetworks.net\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"surgex-seq-power-conditioner-sequencer","title":"SurgeX SEQ Power conditioner + sequencer","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SEQ is a commercial-grade 120V, 20-amp AC power sequencer and power conditioner designed for AV system integration in professional rack-mount installations. As a primary keyword target for \u003cstrong\u003eAV power sequencer with surge protection\u003c\/strong\u003e, the SEQ addresses one of the most common sources of AV system failure: uncontrolled power-up order. The unit combines three sequenced outlet banks with SurgeX Advanced Series Mode surge elimination, making it an essential component for conference room AV racks, broadcast studios, and large-format AV deployments where equipment startup sequence directly affects system reliability and audio quality.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe SurgeX SEQ occupies two rack spaces in a standard 19-inch equipment rack and provides fourteen 120V rear-panel receptacles: two always-on outlets and twelve across three independently sequenced banks (A, B, C) of four receptacles each. This structure gives the AV integrator precise control over which device classes receive power first — typically displays and processors before amplifiers — to prevent the audible pops and damaging inrush currents that occur during simultaneous power-up of an entire rack system.\u003c\/p\u003e\u003cp\u003eA three-line backlit LCD on the front panel displays live status information and serves as the interface for all programming. Two screwdriver-accessible rotary encoders allow the installer to configure time delays between bank sequences, voltage thresholds, remote input behavior, and power-failure recovery mode without removing the unit from the rack. An optional password of up to six characters protects the configuration from unauthorized changes.\u003c\/p\u003e\u003cp\u003eThe SEQ's built-in AC voltmeter uses peak-reading technology to accurately reflect the voltage actually available to connected equipment rather than the RMS average, providing a more meaningful indicator for troubleshooting power quality in commercial AV environments. The unit's Advanced Series Mode technology eliminates surge energy up to 6,000 volts with zero let-through voltage, and produces no ground contamination or common-mode disturbances — a critical consideration in noise-sensitive audio installations.\u003c\/p\u003e\u003cp\u003eFor larger AV systems, two or more SEQ units can be daisy-chained to extend sequenced power control across additional rack positions. The programmable auxiliary relay output and 12V DC output allow the SEQ to control other SurgeX products or downstream AV equipment, while three remote-control inputs accept DC voltages from 5V to 30V or contact closures from control systems such as AMX, Crestron, or Extron. All connections are made at the rear panel, keeping front-panel access clean and rack servicing straightforward.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Sequenced Outlet Banks\u003c\/strong\u003e — Four receptacles per bank (A, B, C) with programmable time delays to prevent inrush current stacking and audible artifacts on power-up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Series Mode Surge Elimination\u003c\/strong\u003e — Eliminates surges up to 6,000 volts with zero let-through voltage; rated A-1-1 under UL 1449 Adjunct Endurance Testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo Always-On Outlets\u003c\/strong\u003e — Dedicated always-on receptacles keep critical reference equipment or network devices powered regardless of sequencing state.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBacklit LCD Display\u003c\/strong\u003e — Three-line display provides real-time voltage and system status, with full menu access for on-site programming without removing the unit from the rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Peak-Reading AC Voltmeter\u003c\/strong\u003e — Monitors peak line voltage rather than RMS average for a more accurate assessment of power quality at the point of equipment load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Control Inputs\u003c\/strong\u003e — Three inputs accept DC voltages (5–30V) or contact closures, enabling integration with building control systems, AMX, Crestron, and Extron processors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaisy-Chain Expandability\u003c\/strong\u003e — Two or more SEQ units can be cascaded together and linked via auxiliary relay to coordinate sequencing across larger multi-rack AV installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable 12V DC Output\u003c\/strong\u003e — Powers LEDs or a small relay to provide visual or electromechanical confirmation feedback for integrators and end users.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePassword Protection\u003c\/strong\u003e — Up to six-character password prevents unauthorized access to sequencing configuration and voltage threshold settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Volatile Memory\u003c\/strong\u003e — All programming is retained through power outages; the unit can be configured to restore its last power state or remain off after a power failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eICE Inrush Current Elimination\u003c\/strong\u003e — Actively manages inrush current at power-up to protect connected equipment and prevent nuisance breaker trips in commercial electrical installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetic Shielding Steel Enclosure\u003c\/strong\u003e — Heavy-gauge steel chassis with magnetic shielding reduces EMI interference to audio signal paths in the same rack.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eHouse of worship\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSEQ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Rating\u003c\/td\u003e\n\u003ctd\u003e20 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space\u003c\/td\u003e\n\u003ctd\u003e2U (3.5\" H x 19\" W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Outlets\u003c\/td\u003e\n\u003ctd\u003e14 (12 sequenced, 2 always-on)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSequenced Banks\u003c\/td\u003e\n\u003ctd\u003e3 banks of 4 receptacles (A, B, C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Let-Through Voltage\u003c\/td\u003e\n\u003ctd\u003e0 volts (6,000V input surge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL 1449 Rating\u003c\/td\u003e\n\u003ctd\u003eA-1-1 (Adjunct Endurance Test)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e5–30V DC or contact closure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable DC Output\u003c\/td\u003e\n\u003ctd\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Relay\u003c\/td\u003e\n\u003ctd\u003eNormally-open contact pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile (NVRAM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eMagnetic shielding steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Cord\u003c\/td\u003e\n\u003ctd\u003e9 ft grounded 3-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003eWhat is the difference between the SurgeX SEQ and the SEQ-1U?\u003c\/dt\u003e\n\u003cdd\u003eThe SEQ is a 2U rack-mount unit with fourteen outlets and a full LCD interface. The SEQ-1U is a 1U form factor with eight outlets and a compact front panel, suited for installations where rack space is limited. Both use the same Advanced Series Mode surge elimination technology.\u003c\/dd\u003e\n\u003cdt\u003eCan the SEQ be integrated with a Crestron or AMX control system?\u003c\/dt\u003e\n\u003cdd\u003eYes. The three remote control inputs accept DC voltages from 5 to 30V or contact closures, which are compatible with relay outputs on Crestron, AMX, Extron, and similar control processors. The programmable 12V DC output and auxiliary relay can also provide status feedback to the control system.\u003c\/dd\u003e\n\u003cdt\u003eHow does power sequencing prevent damage to AV equipment?\u003c\/dt\u003e\n\u003cdd\u003ePowering all devices simultaneously generates stacked inrush current spikes that can trip circuit breakers and cause transient voltage stress on equipment power supplies. Sequential power-up with adjustable time delays between banks distributes the inrush load over time, reducing peak current demand and extending equipment life.\u003c\/dd\u003e\n\u003cdt\u003eWhat happens to the programmed settings after a power failure?\u003c\/dt\u003e\n\u003cdd\u003eAll settings are stored in non-volatile memory and are retained regardless of power interruptions. The unit can be programmed to either restore its previous power-on state automatically or remain off until manually restarted, depending on the installation requirement.\u003c\/dd\u003e\n\u003cdt\u003eCan two SEQ units be connected to handle a larger system?\u003c\/dt\u003e\n\u003cdd\u003eYes. Two or more SEQ units can be daisy-chained. The auxiliary relay output of one SEQ can trigger the remote input of the next unit, allowing coordinated sequencing across multiple rack positions in larger commercial AV installations.\u003c\/dd\u003e\n\u003cdt\u003eDoes the SEQ produce any ground contamination during surge suppression?\u003c\/dt\u003e\n\u003cdd\u003eNo. SurgeX Advanced Series Mode technology absorbs and converts surge energy rather than diverting it to ground. This means no ground contamination and no common-mode disturbances are introduced into the power system — an important consideration in audio-critical environments.\u003c\/dd\u003e\n\u003cdt\u003eIs the SEQ suitable for government or federal installations?\u003c\/dt\u003e\n\u003cdd\u003eYes. The SurgeX product line is rated Grade A, Class 1, Mode 1 per CIDA-A-55818 federal guidelines, meeting the most stringent government purchase specifications for branch circuit surge suppressors.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":42273327481068,"sku":"SEQ","price":2109.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-seq-power-conditioner-sequencer-creation-networks-78967.png?v=1757886819"},{"product_id":"surgex-sx-dc-8-24","title":"SurgeX SX-DC-8-24-120 SQUID 120V Surge Protector and Power Management System","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-DC-8-24-120 SQUID is a compact, network-managed AC and DC power management system that provides 24V DC outputs alongside four controlled AC receptacles in a single device. As a \u003cstrong\u003enetworked 24V DC AV power management system\u003c\/strong\u003e, it is designed for huddle rooms, small conference rooms, and digital signage installations where 24V DC-powered AV equipment — such as PTZ cameras, motorized display mounts, and commercial-grade audio components — must be powered and managed alongside standard AC devices from a unified, remotely accessible interface. It delivers the full SQUID feature set with 24V DC output banks tailored to equipment loads not served by the 12V-only model.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe SX-DC-8-24-120 SQUID accepts universal 120V–240V AC input via IEC connectors and provides four controlled and monitored AC receptacles, three 24V DC output banks (two controllable), and two 5V USB charging ports. The 24V DC output configuration is matched to the power requirements of PTZ camera systems, motorized VESA mounts, LED wall controllers, and commercial audio amplifier accessories that are common in modern AV deployments but require DC voltages above the 12V range.\u003c\/p\u003e\u003cp\u003eAll four AC outlets and the two controllable 24V DC banks are individually switchable via the built-in Ethernet management interface. The web server supports HTTP and HTTPS access with 802.1x port-level authentication, TLS, SSL, SNMP V3, and single sign-on, providing IT-grade security for network-connected power management in enterprise and government environments. Remote outlet control enables AV support teams to power-cycle frozen devices, implement power scheduling, and perform maintenance operations without dispatching a technician to the room.\u003c\/p\u003e\u003cp\u003ePer-outlet power quality monitoring measures voltage, current, power, frequency, power factor, and crest factor in real time. The unit stores 30 days of maximum, minimum, and average values for each parameter, with time-stamped event records for retrospective diagnostics. This monitoring layer allows AV and IT support staff to identify deteriorating power conditions, confirm that protection is active, and document power quality history for compliance or troubleshooting purposes.\u003c\/p\u003e\u003cp\u003eSurgeX Advanced Series Mode technology provides zero let-through voltage surge protection on all AC outlets against events up to 6,000 volts, with no ground contamination or common-mode disturbances. The unit's compact form factor allows installation in furniture chases, ceiling spaces, or behind wall-mounted displays in locations that do not accommodate rack-mount equipment, making it particularly well suited for the furniture-integrated AV systems common in contemporary commercial meeting spaces.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e24V DC Outputs\u003c\/strong\u003e — Three 24V DC banks (two independently controllable) power PTZ cameras, motorized mounts, and other 24V AV peripherals directly from the SQUID without a separate power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour Controlled AC Receptacles\u003c\/strong\u003e — Individually switched and monitored AC outlets with remote on\/off control via the Ethernet management interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork-Managed via Web Server\u003c\/strong\u003e — Built-in HTTP\/HTTPS web server with 802.1x, TLS, SSL, SNMP V3, and single sign-on for enterprise network and NOC integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix-Parameter Power Monitoring\u003c\/strong\u003e — Real-time measurement of voltage, current, power, frequency, power factor, and crest factor per outlet for proactive power quality management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30-Day Power Quality History\u003c\/strong\u003e — Time-stamped event log with Max\/Min\/Avg parameter storage for 30 days, supporting retrospective diagnostics and compliance documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Series Mode Surge Elimination\u003c\/strong\u003e — Zero let-through voltage on AC surges up to 6,000V; no ground contamination or common-mode disturbances produced during suppression events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal AC Input\u003c\/strong\u003e — 120V–240V AC via IEC connector for deployment in North American and international commercial AV environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 x 5V USB Charging Ports\u003c\/strong\u003e — Integrated USB-A charging for room peripherals without a separate charging adapter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Non-Rack Form Factor\u003c\/strong\u003e — Mounts along, behind, or near equipment in huddle rooms, furniture chases, and ceiling spaces where rack-mount equipment is not practical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndividual Outlet and DC Control\u003c\/strong\u003e — Each AC outlet and controllable DC bank switchable independently via the network interface for remote power cycling and scheduling.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHuddle room\u003c\/li\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eAll-hands room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-DC-8-24-120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input\u003c\/td\u003e\n\u003ctd\u003eUniversal 120V–240V via IEC connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Outlets\u003c\/td\u003e\n\u003ctd\u003e4 controlled and monitored receptacles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Outputs\u003c\/td\u003e\n\u003ctd\u003e3 banks: 24V DC (2 controllable, 1 fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Ports\u003c\/td\u003e\n\u003ctd\u003e2 x 5V USB-A charging ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Let-Through Voltage\u003c\/td\u003e\n\u003ctd\u003e0 volts (Advanced Series Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eWired Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeb Server Protocol\u003c\/td\u003e\n\u003ctd\u003eHTTP \/ HTTPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuthentication\u003c\/td\u003e\n\u003ctd\u003e802.1x, TLS, SSL, SNMP V3, single sign-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitored Parameters\u003c\/td\u003e\n\u003ctd\u003eVoltage, Current, Power, Frequency, Power Factor, Crest Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Quality Event Log\u003c\/td\u003e\n\u003ctd\u003eTime-stamped; 30-day Max\/Min\/Avg storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003eWhat AV equipment typically uses 24V DC power?\u003c\/dt\u003e\n\u003cdd\u003eCommon 24V DC AV applications include PTZ camera power supplies, motorized VESA display mounts, certain commercial audio DSP units, RS-485 relay boards, and LED wall controller power inputs. The SX-DC-8-24-120 SQUID is specified for installations where these 24V loads need to be powered, monitored, and remotely switched from the same device managing the AC outlets in the room.\u003c\/dd\u003e\n\u003cdt\u003eHow is the SX-DC-8-24-120 different from the SX-DC-8-12-120 and SX-DC-8-1224-120?\u003c\/dt\u003e\n\u003cdd\u003eAll three SQUID models share the same physical form factor, AC outlet configuration, network management features, and surge protection. The SX-DC-8-24-120 provides 24V DC outputs only; the SX-DC-8-12-120 provides 12V DC only; and the SX-DC-8-1224-120 provides both 12V and 24V. Select the model whose DC output voltage matches the equipment being powered.\u003c\/dd\u003e\n\u003cdt\u003eCan the 24V DC banks be switched independently from the AC outlets?\u003c\/dt\u003e\n\u003cdd\u003eYes. Two of the three 24V DC banks are individually controllable via the network management interface, independently of the four AC outlets. This allows selective power cycling of 24V-powered devices such as a PTZ camera while leaving AC-powered equipment such as a display or codec running.\u003c\/dd\u003e\n\u003cdt\u003eHow does the SQUID connect to an enterprise network?\u003c\/dt\u003e\n\u003cdd\u003eThe SQUID connects via a standard RJ-45 Ethernet port. It supports 802.1x port-level authentication, allowing it to connect to a managed network switch with 802.1x enforcement active — the same security standard used for workstations and IP phones. No special network configuration or unmanaged port exception is required.\u003c\/dd\u003e\n\u003cdt\u003eWhat is the benefit of monitoring crest factor in a meeting room AV system?\u003c\/dt\u003e\n\u003cdd\u003eCrest factor measures how peaked the current draw is relative to its RMS value. Switch-mode power supplies common in AV equipment draw current in sharp pulses, producing a high crest factor. A rising crest factor on a circuit can indicate failing capacitors, overloaded conductors, or deteriorating power supply health — conditions that would not be apparent from voltage monitoring alone.\u003c\/dd\u003e\n\u003cdt\u003eIs the SQUID suitable for use in a furniture-integrated AV system?\u003c\/dt\u003e\n\u003cdd\u003eYes. The compact, non-rack form factor was designed specifically for installation in furniture equipment chases, table cable management trays, and similar confined spaces where standard rack-mount PDUs do not fit. The IEC connector AC input also simplifies field wiring in furniture-integrated environments where a fixed-cord termination is preferable.\u003c\/dd\u003e\n\u003cdt\u003eDoes the SQUID provide any protection beyond surge suppression?\u003c\/dt\u003e\n\u003cdd\u003eThe SQUID's Advanced Series Mode protection addresses voltage surges and transients on the AC inputs. The real-time monitoring of voltage, current, power factor, and crest factor provides early warning of other power quality conditions such as undervoltage, overloading, and power supply degradation. However, it does not include under\/over-voltage shutdown circuitry (COUVS); for installations requiring automatic disconnection during brownout conditions, the SurgeX SX-1115-RT or SX-1120-RT with COUVS would be appropriate for the AC distribution layer.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":42273409433836,"sku":"SX-DC-8-24-120","price":1119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-sx-dc-8-24-120-squid-120v-surge-protector-and-power-management-system-creation-networks-98411.png?v=1757887357"},{"product_id":"surgex-sa-82-flatpak-surge-protector-amp-power-conditioner-for-flat-panel-monitors","title":"SurgeX SA-82 FlatPak Surge Protector \u0026amp; Power Conditioner For Flat Panel Monitors","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SA-82 FlatPak Surge Protector is a compact, lightweight power protection device engineered for commercial AV installations where projectors, flat panel displays, and digital signage must be protected from electrical transients without adding visible hardware to the installation. Weighing just 3 pounds and built around SurgeX Series Mode protection technology, the SA-82 eliminates harmful surge energy before it reaches connected display equipment—delivering commercial-grade power protection in a form factor designed to disappear into the installation. Its non-sacrificial components ensure consistent, maintenance-free protection throughout the product's operating life, making it a practical long-term choice for integrators who need reliable display power protection at a lower cost than IP-enabled models.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe SA-82 FlatPak is purpose-built for concealed deployment behind flat panel displays, projectors, and digital signage in commercial environments where space is limited and equipment visibility must be minimized. Its low-profile enclosure and detachable 3-foot grounded line cord integrate cleanly with wall and ceiling mounting systems, supporting professional installations where exposed hardware is not acceptable.\u003c\/p\u003e\u003cp\u003eSeries Mode power protection technology distinguishes the SA-82 from consumer-grade surge strips. Rather than clamping transient energy and allowing residual voltage to pass through to connected equipment, Series Mode eliminates the transient entirely—an important distinction for projector lamps, display backlights, and control boards that are sensitive to even small levels of let-through energy over time.\u003c\/p\u003e\u003cp\u003eThe magnetically shielded steel enclosure provides EMI suppression, protecting sensitive display signal processing components from electromagnetic interference generated by nearby equipment. Over Voltage Shutdown with Auto Reset automatically disconnects connected equipment during sustained overvoltage events and restores power once voltage returns to a safe level, eliminating the need for a technician to manually reset the unit. Non-sacrificial protection components mean the SA-82 maintains full protection effectiveness throughout its service life without degradation after surge events.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Mode Surge Protection\u003c\/strong\u003e — Eliminates electrical transients completely before they reach connected display equipment, providing superior protection compared to clamping-based devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Sacrificial Components\u003c\/strong\u003e — Maintains full protection effectiveness indefinitely without degrading after transient events or requiring replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver Voltage Shutdown with Auto Reset\u003c\/strong\u003e — Automatically disconnects during overvoltage events and restores power when conditions normalize.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact 3 lb FlatPak Form Factor\u003c\/strong\u003e — Designed to mount discreetly behind or beside flat panels, projectors, and digital signage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetachable 3-Foot Line Cord\u003c\/strong\u003e — Supports clean cable management in display mounting configurations and simplifies service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetic Shielding Steel Enclosure\u003c\/strong\u003e — Reduces electromagnetic interference from nearby equipment, protecting AV signal quality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with Wall and Ceiling Mounting Systems\u003c\/strong\u003e — Integrates with standard commercial display mounting hardware for concealed installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eHuddle room\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eHouse of worship\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSA-82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Cord\u003c\/td\u003e\n\u003ctd\u003eDetachable 3 ft grounded 3-wire #18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Technology\u003c\/td\u003e\n\u003ctd\u003eSeries Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Control\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Voltage Shutdown\u003c\/td\u003e\n\u003ctd\u003eYes, with Auto Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eMagnetic shielding steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponents\u003c\/td\u003e\n\u003ctd\u003eNon-sacrificial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V \/ 208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003eWhat is the difference between the SA-82 and the SA-82-AR?\u003c\/dt\u003e\n\u003cdd\u003eThe SA-82-AR adds IP-enabled remote control and monitoring. The SA-82 provides the same Series Mode protection and FlatPak form factor without network connectivity, making it the right choice for installations that do not require remote power management.\u003c\/dd\u003e\n\u003cdt\u003eHow does the SA-82 mount in a display installation?\u003c\/dt\u003e\n\u003cdd\u003eThe FlatPak enclosure and detachable line cord allow it to be secured behind a flat panel display using standard VESA or proprietary mounting hardware, or affixed to a wall or ceiling mount alongside projector equipment.\u003c\/dd\u003e\n\u003cdt\u003eWhy is Series Mode protection better for display equipment than standard surge strips?\u003c\/dt\u003e\n\u003cdd\u003eStandard MOV-based surge strips clamp surges but allow residual let-through energy to reach connected equipment, and degrade with each event. Series Mode eliminates transient energy entirely, providing consistent protection that does not weaken over time—critical for protecting expensive display hardware.\u003c\/dd\u003e\n\u003cdt\u003eDoes the Over Voltage Shutdown require manual intervention after triggering?\u003c\/dt\u003e\n\u003cdd\u003eNo. The Auto Reset function automatically restores power once line voltage returns to within safe operating parameters, minimizing downtime in installations where physical access is limited.\u003c\/dd\u003e\n\u003cdt\u003eIs the SA-82 appropriate for ceiling-mounted projector installations?\u003c\/dt\u003e\n\u003cdd\u003eYes. Its compact weight and form factor make it easy to mount alongside ceiling-mounted projectors, and the 3-foot detachable cord keeps cable runs clean in finished ceiling installations.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":42273410416876,"sku":"SA-82","price":549.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-sa-82-flatpak-surge-protector-andamp-power-conditioner-for-flat-panel-monitors-creation-networks-79863.png?v=1757887375"},{"product_id":"surgex-sa-82-ar-3-outlet-power-conditioner-and-surge-protector-ip-enabled","title":"SurgeX SA-82-AR 3 Outlet Power Conditioner and Surge Protector, IP Enabled","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SA-82-AR is a compact FlatPak power conditioner and surge protector built for commercial AV installations where space is limited and equipment visibility must be minimized. Designed specifically to protect projectors, flat panel displays, and digital signage from harmful electrical transients, the SA-82-AR deploys discreetly behind or beside display equipment and integrates cleanly with wall and ceiling mounting systems. IP-enabled remote control capabilities allow AV integrators to manage and monitor power remotely without physical access to the installation location. Series Mode power protection technology ensures complete transient elimination, not just clamping, safeguarding sensitive display electronics from power quality issues that cause premature failure.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe SA-82-AR FlatPak Surge Protector weighs just 3 pounds and features a low-profile form factor purpose-built for concealed mounting behind flat panel displays, projectors, and digital signage in commercial environments. Its detachable 3-foot grounded 3-wire line cord provides clean cable management when integrated with display mounting hardware, keeping installations looking professional and minimizing exposed cabling.\u003c\/p\u003e\u003cp\u003eNon-sacrificial Series Mode protection components mean the SA-82-AR delivers consistent protection from day one through the life of the installation—there is no degradation of protection after transient events, and no need to schedule replacement. The integrated Over Voltage Shutdown with Auto Reset function protects connected equipment from sustained overvoltage conditions and automatically restores power once voltage returns to safe operating levels, without requiring a technician on-site.\u003c\/p\u003e\u003cp\u003eThe IP control capability connects the SA-82-AR to the facility network, enabling remote power cycling, status monitoring, and fault reporting through compatible AV control systems. This is particularly valuable in conference rooms, training rooms, and commercial meeting spaces where display equipment is installed in ceiling or wall positions that are difficult to access. The magnetic shielding steel enclosure reduces electromagnetic interference and provides a durable housing appropriate for permanent commercial installation.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Mode Power Protection\u003c\/strong\u003e — Completely eliminates electrical transients rather than clamping, delivering full protection to projectors and flat panel displays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP-Enabled Remote Control\u003c\/strong\u003e — Provides remote power cycling, outlet monitoring, and fault alerts through a networked AV control system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver Voltage Shutdown with Auto Reset\u003c\/strong\u003e — Automatically disconnects during overvoltage events and restores power when conditions normalize, without manual intervention.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Sacrificial Components\u003c\/strong\u003e — Protection circuitry maintains full effectiveness throughout the product's life without degrading after surge events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact 3 lb FlatPak Design\u003c\/strong\u003e — Low-profile enclosure hides behind or beside display equipment and integrates with standard wall and ceiling mounting systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetachable 3-Foot Line Cord\u003c\/strong\u003e — Supports clean cable management in display mounting configurations and simplifies installation and service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetic Shielding Steel Enclosure\u003c\/strong\u003e — Minimizes electromagnetic interference from nearby equipment, protecting AV signal quality.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eHuddle room\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eHouse of worship\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSA-82-AR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Cord\u003c\/td\u003e\n\u003ctd\u003eDetachable 3 ft grounded 3-wire #18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Technology\u003c\/td\u003e\n\u003ctd\u003eSeries Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Control\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Voltage Shutdown\u003c\/td\u003e\n\u003ctd\u003eYes, with Auto Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eMagnetic shielding steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponents\u003c\/td\u003e\n\u003ctd\u003eNon-sacrificial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V \/ 208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003eWhat display equipment is the SA-82-AR designed to protect?\u003c\/dt\u003e\n\u003cdd\u003eIt is designed primarily for projectors, flat panel displays, and digital signage in commercial AV installations, though it can protect any sensitive electronic equipment that fits within its outlet and amperage ratings.\u003c\/dd\u003e\n\u003cdt\u003eHow does the SA-82-AR mount with display equipment?\u003c\/dt\u003e\n\u003cdd\u003eThe FlatPak form factor and detachable line cord allow it to mount behind or beside flat panels using standard wall and ceiling mounting hardware. It is designed to remain out of sight in finished installations.\u003c\/dd\u003e\n\u003cdt\u003eWhat does IP-enabled control allow an AV integrator to do?\u003c\/dt\u003e\n\u003cdd\u003eThrough the IP control port, integrators can remotely cycle power, monitor outlet status, and receive alerts about fault conditions—eliminating the need for physical access to ceiling-mounted or wall-recessed installations.\u003c\/dd\u003e\n\u003cdt\u003eHow is Series Mode protection better than standard surge protection for display equipment?\u003c\/dt\u003e\n\u003cdd\u003eSeries Mode eliminates transient energy entirely rather than clamping and redirecting it. This is important for display equipment because residual let-through energy from clamping devices can cause pixel damage, shortened backlight life, and control board failures over time.\u003c\/dd\u003e\n\u003cdt\u003eWill the protection need replacement after a power surge?\u003c\/dt\u003e\n\u003cdd\u003eNo. Non-sacrificial components maintain their protective effectiveness regardless of how many transient events occur, unlike MOV-based devices that degrade with each event and must eventually be replaced.\u003c\/dd\u003e\n\u003cdt\u003eWhat is the difference between the SA-82 and SA-82-AR?\u003c\/dt\u003e\n\u003cdd\u003eThe SA-82-AR includes IP-enabled remote control and monitoring functionality. The standard SA-82 provides the same Series Mode protection and FlatPak form factor without the network control capability.\u003c\/dd\u003e\n\u003cdt\u003eIs the SA-82-AR suitable for installations using ceiling-mounted projectors?\u003c\/dt\u003e\n\u003cdd\u003eYes. The compact form factor and IP remote control make it particularly well-suited for ceiling projector installations where physical access for power cycling or status checks would otherwise require a ladder or lift.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":42273410744556,"sku":"SA-82-AR","price":1019.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-sa-82-ar-3-outlet-power-conditioner-and-surge-protector-ip-enabled-creation-networks-49729.png?v=1757887381"},{"product_id":"surgex-sx-dc-8-1224","title":"SurgeX SX-DC-8-1224-120 SQUID 120V Surge Protector and Power Management System","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-DC-8-1224-120 SQUID is a compact, network-managed AC and DC power management system that provides both 12V and 24V DC outputs alongside four controlled AC receptacles in a single device. As a \u003cstrong\u003enetworked AC\/DC power management system with dual DC voltages\u003c\/strong\u003e, it is designed for AV installations where equipment requiring different DC voltages — such as 12V camera encoders and 24V display mounts or PTZ motors — must be powered and managed together in a confined space such as a huddle room, meeting space, or digital signage enclosure. The dual-voltage DC capability distinguishes it from the single-voltage SX-DC-8-12-120 and SX-DC-8-24-120 SQUID variants.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe SX-DC-8-1224-120 accepts universal 120V–240V AC input via IEC connectors and provides four controlled and monitored AC receptacles, three DC output banks (two controllable, delivering both 12V and 24V DC), and two 5V USB charging ports. The dual DC voltage architecture eliminates the need for separate power supplies at different voltage levels, reducing the device count and cabling complexity that typically accumulates in small-room AV deployments.\u003c\/p\u003e\u003cp\u003eEthernet connectivity enables a built-in web server accessible via HTTP and HTTPS, with 802.1x port authentication, TLS, SSL, SNMP V3, and single sign-on support. This management capability allows AV operators and IT administrators to monitor outlet-level power consumption, switch individual AC and DC outputs on or off, review power quality event logs, and integrate the unit into a Network Operations Center environment without requiring physical access to each room.\u003c\/p\u003e\u003cp\u003eReal-time power quality monitoring measures voltage, current, power, frequency, power factor, and crest factor at each AC outlet. The unit stores 30 days of maximum, minimum, and average values for each parameter, with time-stamped event logging for retrospective analysis of power anomalies. This data layer is particularly useful in managed deployments where IT and AV support teams need to diagnose intermittent equipment problems without dispatching a technician.\u003c\/p\u003e\u003cp\u003eSurgeX Advanced Series Mode technology provides zero let-through voltage surge protection on all AC outlets against events up to 6,000 volts, with no ground contamination or common-mode disturbances. The compact form factor allows the unit to be deployed along the back of a table, inside a furniture chase, or behind a wall-mounted display — locations where a traditional rack-mount PDU is not practical but power protection and management are still required.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual DC Voltage Outputs (12V and 24V)\u003c\/strong\u003e — Provides both 12V and 24V controllable DC banks in a single unit, replacing separate power supplies for mixed-voltage AV equipment deployments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour Controlled AC Receptacles\u003c\/strong\u003e — Independently switchable AC outlets with per-outlet monitoring; supports remote power cycling without on-site technician access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork-Managed via Web Server\u003c\/strong\u003e — Built-in HTTP\/HTTPS web server with 802.1x, TLS, SSL, SNMP V3, and single sign-on for enterprise-grade remote management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix-Parameter Power Monitoring\u003c\/strong\u003e — Real-time measurement of voltage, current, power, frequency, power factor, and crest factor per outlet for proactive power quality diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30-Day Power Quality History\u003c\/strong\u003e — Time-stamped event log with Max\/Min\/Avg parameter storage for 30 days; supports retrospective analysis and compliance documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Series Mode Surge Elimination\u003c\/strong\u003e — Zero let-through voltage on AC surges up to 6,000V; no ground contamination or common-mode disturbances introduced into the AC system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal AC Input\u003c\/strong\u003e — 120V–240V AC via IEC connector supports deployment in North American and international commercial AV installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 x 5V USB Charging Ports\u003c\/strong\u003e — Integrated USB-A charging for room controllers, tablets, and USB-powered accessories without requiring a separate USB charger.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Non-Rack Form Factor\u003c\/strong\u003e — Designed to mount along, behind, or near equipment in locations where rack-mount installation is not available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSNMP V3 Support\u003c\/strong\u003e — Enables integration with enterprise monitoring platforms and Network Operations Center dashboards for centralized power management across multiple rooms.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHuddle room\u003c\/li\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eAll-hands room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-DC-8-1224-120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input\u003c\/td\u003e\n\u003ctd\u003eUniversal 120V–240V via IEC connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Outlets\u003c\/td\u003e\n\u003ctd\u003e4 controlled and monitored receptacles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Outputs\u003c\/td\u003e\n\u003ctd\u003e3 banks: 12V DC and 24V DC (2 controllable, 1 fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Ports\u003c\/td\u003e\n\u003ctd\u003e2 x 5V USB-A charging ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Let-Through Voltage\u003c\/td\u003e\n\u003ctd\u003e0 volts (Advanced Series Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eWired Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeb Server Protocol\u003c\/td\u003e\n\u003ctd\u003eHTTP \/ HTTPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuthentication\u003c\/td\u003e\n\u003ctd\u003e802.1x, TLS, SSL, SNMP V3, single sign-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitored Parameters\u003c\/td\u003e\n\u003ctd\u003eVoltage, Current, Power, Frequency, Power Factor, Crest Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Quality Event Log\u003c\/td\u003e\n\u003ctd\u003eTime-stamped; 30-day Max\/Min\/Avg storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003eWhat makes the SX-DC-8-1224-120 different from the other SQUID models?\u003c\/dt\u003e\n\u003cdd\u003eThe SX-DC-8-1224-120 provides both 12V and 24V DC output banks in the same unit. The SX-DC-8-12-120 provides only 12V DC outputs, and the SX-DC-8-24-120 provides only 24V DC outputs. If an AV installation includes equipment that requires both voltages — for example, a 12V codec and a 24V PTZ motor driver — the SX-DC-8-1224-120 is the appropriate choice.\u003c\/dd\u003e\n\u003cdt\u003eWhich AV devices typically require 24V DC power?\u003c\/dt\u003e\n\u003cdd\u003eCommon 24V DC-powered AV components include PTZ camera power supplies, motorized display mounts, certain audio DSP units, and some LED driver circuits. Specifying the SX-DC-8-1224-120 SQUID accommodates these alongside 12V accessories such as camera encoders, extender baluns, and video conferencing peripherals in the same compact unit.\u003c\/dd\u003e\n\u003cdt\u003eHow does remote outlet switching work in practice?\u003c\/dt\u003e\n\u003cdd\u003eEach AC outlet and controllable DC bank can be switched on or off individually through the SQUID's web interface, accessible via any browser on the same network. This allows an AV support team to remotely power-cycle a frozen codec, display, or camera without dispatching a technician to the room — a significant operational advantage in large multi-room deployments.\u003c\/dd\u003e\n\u003cdt\u003eCan the SQUID be integrated with an enterprise IT monitoring system?\u003c\/dt\u003e\n\u003cdd\u003eYes. SNMP V3 support allows the SQUID to report power quality data and receive control commands from standard enterprise monitoring platforms such as SolarWinds, PRTG, or Nagios. This makes the SQUID compatible with IT-managed infrastructure where AV power monitoring is consolidated alongside network and server monitoring.\u003c\/dd\u003e\n\u003cdt\u003eDoes the SQUID require a rack for installation?\u003c\/dt\u003e\n\u003cdd\u003eNo. The compact form factor is specifically designed for non-rack environments. The unit can be mounted along the back of a conference table, inside a furniture equipment chase, in a ceiling space above a projector, or behind a wall-mounted display where a rack-mount PDU would not fit.\u003c\/dd\u003e\n\u003cdt\u003eWhat does crest factor measurement indicate about an AV system?\u003c\/dt\u003e\n\u003cdd\u003eCrest factor is the ratio of peak current to RMS current. A high crest factor indicates that power supplies are drawing current in short, sharp pulses rather than smoothly, which increases thermal stress on conductors and can cause voltage distortion on shared circuits. Monitoring crest factor alongside voltage and power gives AV technicians early warning of power quality conditions that could affect equipment reliability.\u003c\/dd\u003e\n\u003cdt\u003eIs there a mobile or remote dashboard for monitoring multiple SQUID units?\u003c\/dt\u003e\n\u003cdd\u003eEach SQUID unit is accessible via its individual HTTPS web interface from any browser, including mobile devices. For centralized management of multiple units, SNMP V3 integration with an existing NOC or monitoring platform provides a unified view across a distributed installation.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":42273411727596,"sku":"SX-DC-8-1224-120","price":1119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-sx-dc-8-1224-120-squid-120v-surge-protector-and-power-management-system-creation-networks-73619.png?v=1757887387"},{"product_id":"surgex-sx-dc-8-12","title":"SurgeX SX-DC-8-12-120 SQUID 120V Surge Protector and Power Management System","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-DC-8-12-120 SQUID is a compact, network-managed AC and DC power management system designed for small meeting spaces, huddle rooms, and digital signage deployments. As a \u003cstrong\u003enetworked AC\/DC power management system for AV\u003c\/strong\u003e, the SQUID consolidates surge-protected AC outlets, controllable 12V DC outputs, wired Ethernet management, and comprehensive power quality monitoring into a single device. It replaces the multiple discrete products — AC surge protector, DC power supply, and network-accessible PDU — that would otherwise be required to power and manage a modern small-room AV system.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe SX-DC-8-12-120 SQUID accepts universal 120V–240V AC input via IEC connectors and provides four controlled and monitored AC receptacles, three DC output banks (two of which are controllable), and two 5V USB charging ports in a form factor compact enough to mount alongside, behind, or beneath equipment rather than consuming rack space. The 12V DC output banks are sized for the camera controllers, codecs, and display extenders commonly found in modern huddle room and video conferencing deployments.\u003c\/p\u003e\u003cp\u003eEthernet connectivity provides access to a built-in web server supporting both HTTP and HTTPS, with 802.1x port-level authentication for network security compliance. The management interface supports TLS, SSL, SNMP V3, and single sign-on, giving IT administrators and AV operators the ability to monitor, control, and audit power across distributed installations from a single Network Operations Center. Individual outlet control, live measurement data, and power quality event logs are all accessible remotely without requiring a technician on site.\u003c\/p\u003e\u003cp\u003eThe SQUID measures six electrical parameters per outlet in real time: voltage, current, power, frequency, power factor, and crest factor. These measurements provide the diagnostic data needed to identify power quality issues before they cause equipment failures or system downtime. Time-stamped power quality events and 30 days of stored maximum, minimum, and average parameter data allow retrospective analysis of power conditions during any previous incident.\u003c\/p\u003e\u003cp\u003eSurgeX Advanced Series Mode surge elimination technology protects all AC outlets against surges up to 6,000 volts with zero let-through voltage, producing no ground contamination or common-mode disturbances. This level of protection, combined with the SQUID's compact form factor and network management capability, makes it a practical choice for IT-managed AV deployments where power protection and remote monitoring are both required but rack space is not available.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated AC and DC Power\u003c\/strong\u003e — Four controlled AC receptacles and three 12V DC banks (two controllable) in a single compact device, eliminating separate power supply and surge protector requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork-Managed via Web Server\u003c\/strong\u003e — Built-in HTTP\/HTTPS web server with 802.1x authentication, TLS, SSL, SNMP V3, and single sign-on for IT-grade remote management and NOC integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix-Parameter Power Monitoring\u003c\/strong\u003e — Real-time measurement of voltage, current, power, frequency, power factor, and crest factor per outlet for proactive power quality management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30-Day Power Quality History\u003c\/strong\u003e — Stores Max\/Min\/Average electrical parameters for 30 days with time-stamped event logging for retrospective diagnostics and compliance documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Series Mode Surge Elimination\u003c\/strong\u003e — Zero let-through voltage on AC surges up to 6,000V; no ground contamination or common-mode disturbances affecting connected equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal AC Input\u003c\/strong\u003e — Accepts 120V–240V AC input via IEC connectors for deployment in both domestic and international AV installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 x 5V USB Charging Ports\u003c\/strong\u003e — Provides USB-A charging for room peripherals such as video conferencing room controllers, tablets, and USB-powered accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Form Factor\u003c\/strong\u003e — Designed to mount along, behind, or near equipment in huddle rooms and digital signage installations where rack space is unavailable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndividual Outlet Control\u003c\/strong\u003e — Each AC outlet and controllable DC bank can be switched independently via the network management interface for remote power cycling and scheduling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e802.1x Network Authentication\u003c\/strong\u003e — Supports enterprise network security requirements, allowing the SQUID to connect to managed network infrastructure without a security exception.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHuddle room\u003c\/li\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eAll-hands room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-DC-8-12-120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input\u003c\/td\u003e\n\u003ctd\u003eUniversal 120V–240V via IEC connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Outlets\u003c\/td\u003e\n\u003ctd\u003e4 controlled and monitored receptacles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Outputs\u003c\/td\u003e\n\u003ctd\u003e3 banks: 12V DC (2 controllable, 1 fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Ports\u003c\/td\u003e\n\u003ctd\u003e2 x 5V USB-A charging ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Let-Through Voltage\u003c\/td\u003e\n\u003ctd\u003e0 volts (Advanced Series Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eWired Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeb Server Protocol\u003c\/td\u003e\n\u003ctd\u003eHTTP \/ HTTPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuthentication\u003c\/td\u003e\n\u003ctd\u003e802.1x, TLS, SSL, SNMP V3, single sign-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitored Parameters\u003c\/td\u003e\n\u003ctd\u003eVoltage, Current, Power, Frequency, Power Factor, Crest Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Quality Event Log\u003c\/td\u003e\n\u003ctd\u003eTime-stamped; 30-day Max\/Min\/Avg storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003eWhat does the SQUID replace in a typical huddle room AV installation?\u003c\/dt\u003e\n\u003cdd\u003eThe SQUID replaces a separate AC surge protector, one or more DC power supplies for 12V AV devices, and a network-accessible PDU. By combining all three in a single compact unit with Ethernet management, it reduces both the hardware count and the cabling complexity in small-room AV deployments.\u003c\/dd\u003e\n\u003cdt\u003eHow is the SX-DC-8-12-120 different from the SX-DC-8-24-120 and SX-DC-8-1224-120 SQUID models?\u003c\/dt\u003e\n\u003cdd\u003eAll three SQUID models share the same form factor, AC outlet configuration, network management features, and surge protection. They differ in DC output voltage: the SX-DC-8-12-120 provides 12V DC outputs, the SX-DC-8-24-120 provides 24V DC outputs, and the SX-DC-8-1224-120 provides both 12V and 24V DC outputs in the same unit.\u003c\/dd\u003e\n\u003cdt\u003eCan I manage multiple SQUID units from a single interface?\u003c\/dt\u003e\n\u003cdd\u003eYes. Each SQUID unit connects to the network independently and can be accessed via its individual web server interface. For centralized management across multiple locations, the units support SNMP V3, which allows them to be integrated into an enterprise Network Operations Center or AV monitoring platform.\u003c\/dd\u003e\n\u003cdt\u003eWhat electrical parameters does the SQUID monitor, and why does that matter?\u003c\/dt\u003e\n\u003cdd\u003eThe SQUID measures voltage, current, power, frequency, power factor, and crest factor in real time per outlet. Crest factor, in particular, is a useful indicator of non-linear loads and power supply stress that standard voltage monitoring alone would miss. Having this data available remotely allows AV technicians to identify deteriorating power conditions before they cause equipment failures.\u003c\/dd\u003e\n\u003cdt\u003eHow do the controllable DC outputs work?\u003c\/dt\u003e\n\u003cdd\u003eTwo of the three DC output banks are independently switchable via the network management interface. This allows remote power cycling of connected DC-powered devices such as camera encoders, display controllers, or codec accessories without requiring physical access to the room.\u003c\/dd\u003e\n\u003cdt\u003eDoes the SQUID require a dedicated IT network port with special configuration?\u003c\/dt\u003e\n\u003cdd\u003eThe SQUID supports 802.1x port-level authentication, which means it can authenticate against an enterprise RADIUS server and connect to managed network infrastructure without requiring an unmanaged or open network port. It also supports VLAN tagging in environments where AV and data networks are separated.\u003c\/dd\u003e\n\u003cdt\u003eIs the SQUID suitable for international deployments?\u003c\/dt\u003e\n\u003cdd\u003eYes. The universal 120V–240V AC input via IEC connectors makes the SQUID compatible with commercial electrical systems worldwide, including both North American 120V and European\/international 240V installations.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":42273411924204,"sku":"SX-DC-8-12-120","price":1119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-sx-dc-8-12-120-squid-120v-surge-protector-and-power-management-system-creation-networks-12872.png?v=1757887389"},{"product_id":"surgex-sx-ds-208-defender-series-8-outlet-power-conditioner","title":"SurgeX SX-DS-208-GFI – Defender Series 8-Outlet Power Conditioner, 20A, GFI Compatible","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-DS-208 Defender Series is an 8-outlet power protection and conditioning unit built for commercial AV installations where comprehensive protection is required without exceeding a tight budget. Part of the SurgeX Defender Series line developed specifically for everyday AV system applications, the SX-DS-208 ensures that essential power protection is part of every system design regardless of project scale. Engineered to deliver the lowest amount of let-through energy along with over voltage shutdown protection, the SX-DS-208 provides a solid power protection foundation for small commercial AV deployments at an accessible price point.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-DS-208 brings the Defender Series power protection architecture to AV installations where eight protected outlets are needed and budget considerations are a primary factor in product selection. Designed to prevent the common mistake of omitting power protection from smaller system deployments, the SX-DS-208 establishes a commercial-grade protective baseline for the connected AV equipment.\u003c\/p\u003e\u003cp\u003eThe over voltage shutdown function automatically disconnects connected equipment when line voltage reaches potentially damaging levels—protecting displays, media players, audio amplifiers, and control hardware from overvoltage events that standard power strips do not address. The emphasis on minimizing let-through energy means that transient events that reach the unit are substantially reduced before they can affect connected equipment, which is the core function that separates commercial power protection products from basic retail surge strips.\u003c\/p\u003e\u003cp\u003eFor AV integrators building systems in huddle rooms, small conference rooms, and multi-purpose spaces where a higher-tier SurgeX product is not within scope, the SX-DS-208 provides an appropriate, code-defensible power protection specification. It operates on both 120V and 208V systems, giving it applicability across the range of commercial building electrical environments commonly encountered in AV system integration work.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLowest Let-Through Energy\u003c\/strong\u003e — Reduces surge energy reaching connected equipment to the minimum possible, providing meaningful transient protection at an entry-level price.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver Voltage Shutdown Protection\u003c\/strong\u003e — Disconnects connected equipment automatically when line voltage rises to dangerous levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8-Outlet Configuration\u003c\/strong\u003e — Supports complete small-room AV system deployments from a single power protection unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial-Grade SurgeX Construction\u003c\/strong\u003e — Built to the same quality and reliability standards as higher-tier SurgeX products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120V and 208V Compatibility\u003c\/strong\u003e — Suitable for use across a broad range of commercial electrical environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBudget-Appropriate Power Protection\u003c\/strong\u003e — Ensures essential protection is included in every commercial AV installation regardless of project budget.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHuddle room\u003c\/li\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-DS-208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceptacles\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Voltage Shutdown\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLet-Through Energy\u003c\/td\u003e\n\u003ctd\u003eLowest in class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eDefender Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V \/ 208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003eWhy specify the SX-DS-208 instead of a retail surge strip for a small AV installation?\u003c\/dt\u003e\n\u003cdd\u003eRetail surge strips typically use MOV-based protection that degrades after each transient event and provides limited real let-through energy reduction. The SX-DS-208 is built to commercial standards with engineered let-through energy minimization and over voltage shutdown—features that protect AV equipment more effectively and last longer than consumer alternatives.\u003c\/dd\u003e\n\u003cdt\u003eWhat type of equipment does the SX-DS-208 protect?\u003c\/dt\u003e\n\u003cdd\u003eIt is suitable for any commercial AV equipment that operates within its outlet and amperage specifications, including flat panel displays, projectors, media players, audio amplifiers, wireless receivers, and control systems.\u003c\/dd\u003e\n\u003cdt\u003eWhat does over voltage shutdown do that standard surge protection does not?\u003c\/dt\u003e\n\u003cdd\u003eStandard surge protection addresses fast transient spikes. Over voltage shutdown addresses sustained overvoltage conditions—when line voltage remains elevated above safe operating levels for an extended period—which can damage equipment even if no sharp spike is present.\u003c\/dd\u003e\n\u003cdt\u003eIs the SX-DS-208 suitable for both 120V and 208V commercial circuits?\u003c\/dt\u003e\n\u003cdd\u003eYes. The 120V\/208V compatibility allows it to be deployed across different commercial building electrical configurations without requiring a separate unit for each voltage environment.\u003c\/dd\u003e\n\u003cdt\u003eWhat is the difference between the SX-DS-158 and SX-DS-208?\u003c\/dt\u003e\n\u003cdd\u003eBoth are 8-outlet Defender Series units with the same core protection features. Review specific product documentation for form factor, cord length, or mounting differences that may affect installation requirements for a particular project.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":42273708507372,"sku":"SX-DS-208-GFI","price":399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-sx-ds-208-defender-series-8-outlet-power-conditioner-creation-networks-87129.png?v=1757888564"},{"product_id":"surgex-sa-20-ar-ready-surge-eliminator","title":"SurgeX SA-20-AR Ready Surge Eliminator","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SA-20-AR is a commercial-grade standalone surge eliminator designed to protect mission-critical AV equipment installed outside of a rack enclosure. Using SurgeX Series Mode power protection technology, the SA-20-AR eliminates destructive electrical transients at the source rather than clamping and re-releasing them, making it a dependable choice for permanent AV system integration in commercial environments. With IP-enabled remote monitoring and control, AV integrators can manage power protection remotely—ideal for distributed systems where physical access is limited. The SA-20-AR supports both 120V and 208V applications, giving it the flexibility to deploy across a broad range of commercial installations.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe SurgeX SA-20-AR Surge Eliminator provides non-sacrificial surge protection, meaning the protection components do not degrade over time or require replacement after a transient event—a critical advantage over MOV-based devices commonly found in consumer-grade power strips. Its compact, magnetically shielded steel enclosure is engineered for discreet placement alongside, behind, or beneath AV equipment where rack mounting is not practical.\u003c\/p\u003e\u003cp\u003eWith ten receptacles and a 9-foot grounded 3-wire power cord, the SA-20-AR accommodates multi-component AV systems in a single unit. The integrated Over Voltage Shutdown with Auto Reset protects connected equipment from sustained overvoltage conditions without requiring manual intervention. The IP control capability enables remote power cycling, monitoring, and status reporting through a networked AV control system, making it compatible with modern building automation and AV-over-IP architectures.\u003c\/p\u003e\u003cp\u003eFor AV integrators specifying power protection in conference rooms, government spaces, or boardroom installations where reliability and remote management are requirements, the SA-20-AR delivers enterprise-level power protection in a form factor that installs cleanly without rack space. It is fully suitable for use in surveillance systems, digital signage networks, and distributed audio systems where uptime is non-negotiable.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Mode Surge Elimination\u003c\/strong\u003e — Eliminates electrical transients completely rather than clamping, ensuring no let-through energy reaches connected equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Sacrificial Components\u003c\/strong\u003e — Protection circuitry does not wear out or degrade after surge events, eliminating the need for replacement units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP-Enabled Remote Control\u003c\/strong\u003e — Allows AV integrators to remotely monitor power status, cycle outlets, and receive alerts through a networked control system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver Voltage Shutdown with Auto Reset\u003c\/strong\u003e — Automatically disconnects equipment during sustained overvoltage and restores power when conditions normalize.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 Receptacle Configuration\u003c\/strong\u003e — Accommodates multi-component AV systems without requiring additional power distribution units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetic Shielding Steel Enclosure\u003c\/strong\u003e — Reduces electromagnetic interference from nearby equipment, protecting sensitive AV signal processing components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9-Foot Grounded Power Cord\u003c\/strong\u003e — Provides installation flexibility for equipment placed away from wall outlets in commercial spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120V and 208V Compatible\u003c\/strong\u003e — Supports a range of commercial electrical systems without requiring a separate transformer or adapter.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eAll-hands room\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSA-20-AR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceptacles\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Cord\u003c\/td\u003e\n\u003ctd\u003e9 ft grounded 3-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Technology\u003c\/td\u003e\n\u003ctd\u003eSeries Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Control\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Voltage Shutdown\u003c\/td\u003e\n\u003ctd\u003eYes, with Auto Reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eMagnetic shielding steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V \/ 208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponents\u003c\/td\u003e\n\u003ctd\u003eNon-sacrificial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003eWhat makes Series Mode surge protection different from MOV-based protection?\u003c\/dt\u003e\n\u003cdd\u003eSeries Mode technology absorbs and dissipates transient energy across a series impedance network, eliminating it entirely. MOV-based devices clamp surges but release residual energy to connected equipment and degrade with each event.\u003c\/dd\u003e\n\u003cdt\u003eDoes the SA-20-AR require rack mounting?\u003c\/dt\u003e\n\u003cdd\u003eNo. It is designed specifically for standalone deployment outside of a rack—it can be placed alongside, behind, or beneath equipment in a commercial AV installation.\u003c\/dd\u003e\n\u003cdt\u003eHow does the IP control feature integrate with an AV control system?\u003c\/dt\u003e\n\u003cdd\u003eThe IP control port connects to the facility network, allowing compatible control systems (such as Crestron or AMX) to issue power cycling commands, monitor outlet status, and receive fault alerts remotely.\u003c\/dd\u003e\n\u003cdt\u003eWill the protection components need to be replaced after a large surge event?\u003c\/dt\u003e\n\u003cdd\u003eNo. The SA-20-AR uses non-sacrificial protection components that do not degrade after transient events, unlike MOV-based devices that must be replaced after significant surges.\u003c\/dd\u003e\n\u003cdt\u003eIs the SA-20-AR appropriate for government and enterprise AV installations?\u003c\/dt\u003e\n\u003cdd\u003eYes. Its non-sacrificial protection, IP monitoring capability, and commercial-grade construction make it well-suited for government spaces, enterprise boardrooms, and other high-reliability commercial environments.\u003c\/dd\u003e\n\u003cdt\u003eWhat is the difference between the SA-20 and SA-20-AR?\u003c\/dt\u003e\n\u003cdd\u003eThe SA-20-AR adds IP-enabled remote control and monitoring capabilities over the standard SA-20 model, making it the preferred choice for networked AV installations requiring remote power management.\u003c\/dd\u003e\n\u003cdt\u003eCan it handle 208V commercial electrical systems?\u003c\/dt\u003e\n\u003cdd\u003eYes. The SA-20-AR supports both 120V and 208V, giving AV integrators flexibility across different commercial building electrical configurations.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":42273718501612,"sku":"SA-20-AR","price":1479.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-sa-20-ar-ready-surge-eliminator-creation-networks-81811.png?v=1757888656"},{"product_id":"surgex-sa-1810-power-conditioner","title":"SurgeX SA-1810 Power Conditioner","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SA-1810 is a standalone power conditioner built for commercial AV and surveillance systems that operate outside of a rack enclosure. Combining Series Mode surge elimination with clean power conditioning in a compact magnetic steel enclosure, the SA-1810 protects sensitive electronics from the full spectrum of power disturbances—surges, spikes, and electrical noise—that degrade equipment performance and shorten operational life. Its 10-outlet configuration handles multi-component AV systems with a single unit, and its non-sacrificial design means protection never diminishes over the course of the installation. The SA-1810 is an ideal power protection solution for integrators specifying dependable, maintenance-free power conditioning in commercial environments where rack mounting is not an option.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe SurgeX SA-1810 Power Conditioner provides commercial AV installers with a standalone power protection solution that goes beyond basic surge protection to address noise filtering and power conditioning needs. Its Series Mode technology eliminates transient energy at the source rather than clamping it, ensuring zero let-through energy reaches connected AV components.\u003c\/p\u003e\u003cp\u003eWith 10 receptacles and a 9-foot grounded power cord, the SA-1810 supports complete AV system installations—from signal processors and amplifiers to displays and control systems—without requiring additional outlet distribution. The compact form factor is designed to sit alongside or behind equipment in furniture installations, equipment closets, and purpose-built AV system cabinets where full rack enclosures are not practical.\u003c\/p\u003e\u003cp\u003eThe magnetically shielded steel enclosure provides both physical durability and EMI suppression, keeping sensitive AV signal processing components free from electromagnetic interference generated by nearby equipment. Non-sacrificial protection components eliminate the service call cycle common with MOV-based consumer surge strips, making the SA-1810 a cost-effective long-term investment in equipment protection for commercial AV integrators and their clients.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Mode Surge Elimination\u003c\/strong\u003e — Completely removes electrical transients rather than clamping, providing superior protection compared to MOV-based devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Sacrificial Components\u003c\/strong\u003e — Protection circuitry maintains effectiveness indefinitely without degrading after surge events or requiring replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 Receptacle Configuration\u003c\/strong\u003e — Supports complete multi-component AV systems from a single standalone power unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetic Shielding Steel Enclosure\u003c\/strong\u003e — Reduces electromagnetic interference that affects AV signal quality and equipment performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9-Foot Grounded Power Cord\u003c\/strong\u003e — Provides placement flexibility for equipment installed away from wall outlets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Standalone Design\u003c\/strong\u003e — Fits alongside, behind, or beneath equipment in furniture installations and equipment closets without requiring rack space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120V and 208V Support\u003c\/strong\u003e — Compatible with a broad range of commercial electrical systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eHouse of worship\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSA-1810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceptacles\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Cord\u003c\/td\u003e\n\u003ctd\u003e9 ft grounded 3-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Technology\u003c\/td\u003e\n\u003ctd\u003eSeries Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eMagnetic shielding steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponents\u003c\/td\u003e\n\u003ctd\u003eNon-sacrificial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V \/ 208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Control\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003eWhat is the primary difference between the SA-1810 and the SA-20-AR?\u003c\/dt\u003e\n\u003cdd\u003eThe SA-20-AR adds IP-enabled remote control and monitoring over the SA-1810. Both use the same Series Mode protection technology and 10-outlet standalone form factor. Choose the SA-1810 for installations that do not require networked power management.\u003c\/dd\u003e\n\u003cdt\u003eDoes the SA-1810 need to be rack-mounted?\u003c\/dt\u003e\n\u003cdd\u003eNo. The Standalone series is specifically designed for deployment outside of rack enclosures—it can be placed alongside, behind, or beneath equipment in commercial AV installations.\u003c\/dd\u003e\n\u003cdt\u003eHow does Series Mode protection benefit a multi-component AV system?\u003c\/dt\u003e\n\u003cdd\u003eSeries Mode eliminates transient energy entirely before it reaches any connected component. In a multi-component system, a single transient event that bypasses standard protection can damage multiple pieces of equipment simultaneously—Series Mode prevents this scenario.\u003c\/dd\u003e\n\u003cdt\u003eWill the protection degrade over time or after surge events?\u003c\/dt\u003e\n\u003cdd\u003eNo. The SA-1810 uses non-sacrificial components that maintain full protection indefinitely, unlike MOV-based devices that lose effectiveness after repeated transients and require periodic replacement.\u003c\/dd\u003e\n\u003cdt\u003eIs the SA-1810 appropriate for surveillance and monitoring systems?\u003c\/dt\u003e\n\u003cdd\u003eYes. SurgeX Standalone units are designed for AV, surveillance, and monitoring system applications where equipment must remain operational continuously without power-related interruptions.\u003c\/dd\u003e\n\u003cdt\u003eWhat is the EMI benefit of the magnetic shielding enclosure?\u003c\/dt\u003e\n\u003cdd\u003eThe steel enclosure with magnetic shielding reduces electromagnetic interference from nearby equipment, which is particularly important in AV installations where signal-processing components are sensitive to EMI-induced noise.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":42273730887916,"sku":"SA-1810","price":819.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-sa-1810-power-conditioner-creation-networks-51448.jpg?v=1757888741"},{"product_id":"surgex-sx-ds-158-defender-series-8-outlet-power-conditioner","title":"SurgeX SX-DS-158-GFI – Defender Series 8-Outlet Power Conditioner, 15A, GFI Compatible","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-DS-158 Defender Series is an 8-outlet power protection unit designed for cost-conscious AV installations that still demand reliable commercial-grade surge protection and power conditioning. Developed specifically for everyday AV system applications where budget constraints are a factor, the Defender Series ensures that power protection is never omitted from a system design—regardless of project scope or size. The SX-DS-158 delivers the lowest amount of let-through energy in its class along with over voltage shutdown protection, providing a defensible power protection foundation for smaller commercial AV deployments.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-DS-158 addresses a common challenge in commercial AV integration: ensuring that even smaller, budget-driven installations receive adequate power protection rather than relying on retail surge strips that provide minimal real-world protection. Designed as an entry point into the SurgeX ecosystem, the Defender Series provides comprehensive power protection without the cost premium of higher-tier models.\u003c\/p\u003e\u003cp\u003eWith eight outlets, the SX-DS-158 accommodates complete small-room AV systems—displays, media players, audio equipment, and control hardware—from a single power protection unit. The over voltage shutdown feature disconnects connected equipment when line voltage rises to dangerous levels, protecting hardware in areas where power quality is inconsistent or unreliable.\u003c\/p\u003e\u003cp\u003eThe Defender Series is built to minimize let-through energy, meaning the amount of surge energy that reaches connected equipment after a transient event is kept as low as possible. This is the fundamental measure of surge protection performance and the SX-DS-158 is engineered to perform well on this metric within its price category. For AV integrators building systems in huddle rooms, training rooms, and smaller conference rooms where a full SurgeX MultiPak or Standalone unit may not fit the project budget, the Defender Series provides an appropriate level of protection at an accessible price point.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLowest Let-Through Energy\u003c\/strong\u003e — Minimizes the surge energy that reaches connected equipment, providing strong transient protection at an accessible price point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver Voltage Shutdown Protection\u003c\/strong\u003e — Automatically disconnects equipment when line voltage rises to potentially damaging levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8-Outlet Configuration\u003c\/strong\u003e — Accommodates complete small-room AV systems on a single power protection unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial-Grade Construction\u003c\/strong\u003e — Built to SurgeX standards for permanent commercial AV installation, not consumer-grade use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCost-Effective Power Protection\u003c\/strong\u003e — Provides a budget-appropriate entry point into the SurgeX product line without omitting essential protection features.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHuddle room\u003c\/li\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-DS-158\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceptacles\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Voltage Shutdown\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLet-Through Energy\u003c\/td\u003e\n\u003ctd\u003eLowest in class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eDefender Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V \/ 208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003eWhat is the Defender Series designed for?\u003c\/dt\u003e\n\u003cdd\u003eThe Defender Series was developed for everyday commercial AV applications where budget is a constraint but power protection cannot be omitted. It provides essential surge protection and over voltage shutdown at a price point accessible for smaller system deployments.\u003c\/dd\u003e\n\u003cdt\u003eHow does the SX-DS-158 compare to the SurgeX MultiPak line?\u003c\/dt\u003e\n\u003cdd\u003eThe MultiPak line adds features including multi-stage protection, inrush current elimination, impedance tolerant noise filtering, wiring fault protection, and analytical software monitoring. The Defender Series focuses on core surge protection and over voltage shutdown at a lower cost, making it appropriate for smaller installations where the full MultiPak feature set is not required.\u003c\/dd\u003e\n\u003cdt\u003eIs 8 outlets sufficient for a complete small-room AV system?\u003c\/dt\u003e\n\u003cdd\u003eFor a typical huddle room or small conference room with a display, media player, wireless presentation receiver, and audio components, 8 outlets is generally sufficient on a single unit.\u003c\/dd\u003e\n\u003cdt\u003eDoes the SX-DS-158 provide the same brand-level reliability as higher SurgeX models?\u003c\/dt\u003e\n\u003cdd\u003eYes. It is designed and built to SurgeX commercial standards. The Defender Series exists to ensure that no commercial AV installation goes without appropriate power protection due to budget constraints, not to cut corners on build quality.\u003c\/dd\u003e\n\u003cdt\u003eWhat is the difference between the SX-DS-158 and SX-DS-208?\u003c\/dt\u003e\n\u003cdd\u003eBoth are 8-outlet Defender Series units. Review the product specifications for each model to identify any differences in form factor, cord length, or mounting options relevant to your installation requirements.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":42273738916076,"sku":"SX-DS-158-GFI","price":359.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-sx-ds-158-defender-series-8-outlet-power-conditioner-creation-networks-24486.png?v=1757888789"},{"product_id":"surgex-sx-ds-156-multipak-surge-suppressor-and-power-filter-multi-array-solution-includes-mounting-brackets-6-outlets","title":"SurgeX SX-DS-156 MultiPak Surge Suppressor and Power Filter, Multi Array Solution, Includes Mounting Brackets, 6 Outlets","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-DS-156 MultiPak is a 6-outlet commercial power conditioner and surge protector designed to safeguard digital displays, signage systems, and associated AV components from the full range of power disturbances that cause equipment failures and costly downtime. Featuring multi-stage surge protection, catastrophic over\/under voltage shutdown, inrush current elimination, and an impedance tolerant noise filter, the SX-DS-156 provides 360 degrees of power protection for commercial display installations requiring more outlets than a 4-outlet unit can accommodate. Integrated analytical software monitors electrical data continuously, giving AV service teams the diagnostic intelligence to identify power anomalies and address root causes before they result in equipment damage or customer-facing display outages.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-DS-156 MultiPak builds on the same proven power protection architecture as the SX-DS-154 while adding two additional outlets to support more complex digital display system configurations. With six outlets and a 6-foot line cord, the SX-DS-156 accommodates displays, media players, signal processors, and control devices within a single, compact power protection unit.\u003c\/p\u003e\u003cp\u003eThe catastrophic over and under voltage shutdown function automatically disconnects all connected equipment when line voltage deviates beyond safe operating limits, protecting expensive display hardware from voltage events that standard surge protectors do not address. Inrush current elimination guards against the high startup currents that stress and eventually damage power supplies, backlight drivers, and control boards in commercial display equipment during power-on sequences.\u003c\/p\u003e\u003cp\u003eThe noise filter uses impedance tolerant technology to clean line noise from incoming power across varying source impedances—an important capability in commercial building electrical systems where line conditions can vary significantly between circuits. Wiring fault protection detects ground and neutral faults at the installation point, alerting technicians to potentially dangerous wiring conditions before they cause equipment damage or safety hazards. Included mounting brackets allow the SX-DS-156 to be permanently secured behind display mounting hardware, inside furniture, or within equipment enclosures for a professional finished installation.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Stage Surge Protection\u003c\/strong\u003e — Defends against surges and transients across all power line modes for comprehensive coverage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatastrophic Over\/Under Voltage Shutdown\u003c\/strong\u003e — Disconnects equipment automatically when line voltage exceeds safe operating parameters in either direction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current Elimination\u003c\/strong\u003e — Prevents startup current spikes from damaging display power supplies and control electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpedance Tolerant Noise Filter\u003c\/strong\u003e — Removes line noise from power in real-world commercial electrical environments with variable source impedance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalytical Software Monitoring\u003c\/strong\u003e — Monitors and logs power quality data, translating anomalies into service recommendations for AV technicians.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Fault Protection\u003c\/strong\u003e — Detects ground and neutral wiring faults at the installation location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6-Outlet Configuration\u003c\/strong\u003e — Supports multi-component display systems with displays, media players, and control hardware on a single unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded Mounting Brackets\u003c\/strong\u003e — Enables professional concealed installation behind displays or inside equipment enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6-Foot Line Cord\u003c\/strong\u003e — Provides reach for in-wall and behind-display installation scenarios.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eHuddle room\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eHouse of worship\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-DS-156\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceptacles\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Cord\u003c\/td\u003e\n\u003ctd\u003e6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eMulti-stage surge, over\/under voltage shutdown, inrush current elimination, noise filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Fault Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalytical Software\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Brackets\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V \/ 208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003eWhen should an AV integrator specify the SX-DS-156 over the SX-DS-154?\u003c\/dt\u003e\n\u003cdd\u003eChoose the SX-DS-156 when the display system configuration includes more than four components—for example, a display with a separate media player, signal processor, control interface, and audio amplifier all requiring protected power from a single unit.\u003c\/dd\u003e\n\u003cdt\u003eWhat does the analytical software actually report?\u003c\/dt\u003e\n\u003cdd\u003eThe analytical software monitors incoming power quality, logs transient events, voltage deviations, and noise levels, and provides service teams with diagnostic information about recurring power issues and recommended corrective actions.\u003c\/dd\u003e\n\u003cdt\u003eHow does wiring fault protection benefit a commercial installation?\u003c\/dt\u003e\n\u003cdd\u003eWiring faults—particularly open ground or reversed neutral conditions—create equipment safety risks and can cause erratic operation or damage. The SX-DS-156 detects these conditions and alerts technicians, preventing equipment damage from undetected wiring problems.\u003c\/dd\u003e\n\u003cdt\u003eCan the SX-DS-156 be mounted behind a flat panel display?\u003c\/dt\u003e\n\u003cdd\u003eYes. Included mounting brackets allow it to be affixed to VESA mounting hardware or mounted inside the enclosure of furniture or millwork installations, keeping the unit out of sight in finished commercial spaces.\u003c\/dd\u003e\n\u003cdt\u003eDoes the over\/under voltage shutdown require manual reset?\u003c\/dt\u003e\n\u003cdd\u003eThis is a protective disconnection function. After a catastrophic voltage event, the unit should be inspected and the connected equipment verified before restoring power. Refer to the product documentation for reset procedures specific to the installation.\u003c\/dd\u003e\n\u003cdt\u003eIs the SX-DS-156 suitable for high-traffic commercial spaces like house of worship or auditorium installations?\u003c\/dt\u003e\n\u003cdd\u003eYes. Its protection coverage, analytical monitoring, and durable construction make it appropriate for permanent installations in high-use commercial venues where display equipment reliability is critical to operations.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":42273739899116,"sku":"SX-DS-156","price":529.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-sx-ds-156-multipak-surge-suppressor-and-power-filter-multi-array-solution-includes-mounting-brackets-6-outlets-creation-networks-25092.png?v=1757888790"},{"product_id":"surgex-sx-ds-154-multipak-surge-suppressor-and-power-filter-multi-array-solution-includes-mounting-brackets-4-outlets","title":"SurgeX SX-DS-154 MultiPak Surge Suppressor and Power Filter, Multi Array Solution, Includes Mounting Brackets, 4 Outlets","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-DS-154 MultiPak is a 4-outlet power conditioner and surge protector engineered to protect digital displays and signage systems from the power disturbances that cause equipment failures, error codes, and operational downtime. Combining multi-stage surge protection, catastrophic over\/under voltage shutdown, inrush current elimination, and an impedance tolerant noise filter, the SX-DS-154 delivers 360 degrees of power protection for commercial display installations. Its analytical software monitors electrical data in real time, enabling service teams to identify power anomalies and act before they cause equipment damage or display outages. The SX-DS-154 is available in four-outlet configuration, offering a compact solution for single or dual-display commercial deployments.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-DS-154 MultiPak addresses the full range of power quality threats that affect digital signage and commercial display equipment. Power disturbances on video, data, and audio lines cause visible symptoms including pixelation, audio crackling, and display error codes—all of which reflect poorly on a business and represent lost operational time. The SX-DS-154 is designed to eliminate these issues at the source by conditioning incoming power before it reaches connected equipment.\u003c\/p\u003e\u003cp\u003eMulti-stage surge protection handles transient events across all modes, while the catastrophic over and under voltage shutdown disconnects equipment automatically when line voltage exceeds safe operating parameters. Inrush current elimination protects against the high startup currents that stress power supplies and control boards during power-on sequences—a common but overlooked source of premature equipment failure in commercial display systems.\u003c\/p\u003e\u003cp\u003eThe integrated analytical software monitors and collects electrical data from the installation, translating power anomalies into actionable service recommendations. This capability helps AV technicians diagnose recurring power issues at a site and make informed decisions about infrastructure improvements. Mounting brackets are included, allowing the SX-DS-154 to be secured behind display mounting hardware or inside equipment enclosures for a clean, permanent installation. Wiring fault protection adds another layer of safety by detecting and responding to ground and neutral wiring faults at the installation location.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Stage Surge Protection\u003c\/strong\u003e — Provides comprehensive protection against surges and spikes across all power line modes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatastrophic Over\/Under Voltage Shutdown\u003c\/strong\u003e — Automatically disconnects equipment when line voltage exceeds or drops below safe operating thresholds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current Elimination\u003c\/strong\u003e — Prevents high startup currents from stressing power supplies and display control boards during power-on cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpedance Tolerant Noise Filter\u003c\/strong\u003e — Filters electrical noise from the power line to ensure display equipment operates without interference-related artifacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalytical Software Monitoring\u003c\/strong\u003e — Collects and analyzes electrical data to identify power anomalies and provide service teams with diagnostic recommendations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Fault Protection\u003c\/strong\u003e — Detects ground and neutral wiring faults at the installation location, adding an additional safety layer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-Outlet Configuration\u003c\/strong\u003e — Right-sized for single or dual-display commercial deployments with associated media players and control hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded Mounting Brackets\u003c\/strong\u003e — Enables secure installation behind display mounting hardware or inside equipment enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6-Foot Line Cord\u003c\/strong\u003e — Provides sufficient reach for most in-wall and behind-display installation scenarios.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eHuddle room\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eHouse of worship\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-DS-154\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceptacles\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Cord\u003c\/td\u003e\n\u003ctd\u003e6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eMulti-stage surge, over\/under voltage shutdown, inrush current elimination, noise filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Fault Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalytical Software\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Brackets\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V \/ 208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003eWhat types of power disturbances does the SX-DS-154 protect against?\u003c\/dt\u003e\n\u003cdd\u003eIt protects against surges, spikes, electrical transients, line noise, catastrophic overvoltage and undervoltage events, inrush current, and wiring faults—covering the full range of power quality issues that affect commercial display equipment.\u003c\/dd\u003e\n\u003cdt\u003eHow does the analytical software benefit an AV service team?\u003c\/dt\u003e\n\u003cdd\u003eThe software monitors and logs electrical data from the installation, identifies patterns indicative of power quality problems, and translates that data into specific recommendations—helping technicians diagnose root causes rather than repeatedly replacing equipment affected by unresolved power issues.\u003c\/dd\u003e\n\u003cdt\u003eWhat is inrush current elimination and why does it matter for displays?\u003c\/dt\u003e\n\u003cdd\u003eInrush current is the spike of electrical current drawn by a device at power-on, which can be several times higher than normal operating current. Repeated inrush events stress power supplies and capacitors in display equipment, shortening their service life. The SX-DS-154 eliminates these spikes before they reach connected equipment.\u003c\/dd\u003e\n\u003cdt\u003eDoes the SX-DS-154 include mounting hardware?\u003c\/dt\u003e\n\u003cdd\u003eYes. Mounting brackets are included to allow secure installation behind flat panel mounts, inside equipment enclosures, or in any position where the unit needs to be affixed rather than free-standing.\u003c\/dd\u003e\n\u003cdt\u003eWhat is the difference between the SX-DS-154 and SX-DS-156?\u003c\/dt\u003e\n\u003cdd\u003eThe SX-DS-156 provides six outlets compared to four on the SX-DS-154. Both models offer identical protection features. Choose the SX-DS-154 for smaller deployments and the SX-DS-156 when additional outlets are needed for more complex display system configurations.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":42273739997420,"sku":"SX-DS-154","price":469.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-sx-ds-154-multipak-surge-suppressor-and-power-filter-multi-array-solution-includes-mounting-brackets-4-outlets-creation-networks-57985.png?v=1757888791"},{"product_id":"surgex-sx-1120-rt-8-outlet-rackmount-surge-suppressor-power-conditioner","title":"SurgeX SX-1120-RT 8-Outlet Rackmount Surge Suppressor - Power Conditioner","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-1120-RT is a 1U rack-mount, 20-amp power conditioner and surge suppressor with remote turn-on capability, designed for commercial AV system integration in conference rooms, boardrooms, and broadcast facilities. As a leading \u003cstrong\u003erackmount power conditioner with remote turn-on\u003c\/strong\u003e, the SX-1120-RT provides eight rear-panel outlets, Advanced Series Mode surge elimination, and comprehensive power conditioning in a compact form factor that integrates directly with Crestron, AMX, and Extron control systems. It meets the federal government Grade A, Class 1, Mode 1 standard (CIDA-A-55818), making it a specification-grade choice for government and institutional AV deployments.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe SX-1120-RT delivers 20 amps at 120V through eight rear-panel grounded receptacles — six switched and two always-on — plus a front-panel courtesy outlet for local access during installation or service. The remote turn-on input accepts 5 to 30V DC, allowing the unit to be powered on and off directly from a control system without requiring a separate relay module or PDU controller.\u003c\/p\u003e\u003cp\u003eSurgeX Advanced Series Mode technology provides zero let-through voltage on surge events up to 6,000 volts and unlimited surge current capacity. Unlike MOV-based designs that divert surge energy to ground and degrade over time, Advanced Series Mode absorbs surge energy within the protection circuitry, producing no ground contamination and no common-mode disturbances. This approach is particularly important in AV installations where ground noise can manifest as audible hum or interference in audio signal paths.\u003c\/p\u003e\u003cp\u003eThe unit features advanced Impedance Tolerant EMI\/RFI filtering circuitry that delivers greater than 40 dB of normal-mode attenuation at 100 kHz, reaching 50 dB at 300 kHz and above. This level of filtering addresses the broadband noise introduced by switching power supplies, LED drivers, dimmer circuits, and HVAC motor loads commonly found in commercial building electrical systems. For common-mode noise, attenuation reaches 50 dB at 5 MHz.\u003c\/p\u003e\u003cp\u003eCOUVS (Catastrophic Over\/Under-Voltage Shutdown) circuitry monitors line voltage continuously and shuts down the switched outlets if voltage falls below 90V or rises above 145V, protecting connected AV equipment from brownout conditions and line fault events. The unit also incorporates SurgeX ICE (Inrush Current Elimination) technology, which manages inrush current at power-up to prevent nuisance breaker trips and reduce stress on equipment power supplies in multi-device rack installations. A self-test circuit with a front-panel visual indicator confirms protection status at a glance.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Turn-On Input\u003c\/strong\u003e — Accepts 5–30V DC for direct integration with Crestron, AMX, Extron, and other AV control systems; eliminates the need for a separate switching relay.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Series Mode Surge Elimination\u003c\/strong\u003e — Zero let-through voltage on surges up to 6,000V with unlimited current handling; no ground contamination or common-mode disturbances introduced.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 Rear-Panel Outlets\u003c\/strong\u003e — Six switched and two always-on receptacles plus a front-panel courtesy outlet for in-rack access during installation and service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpedance Tolerant EMI\/RFI Filtering\u003c\/strong\u003e — Greater than 40 dB normal-mode attenuation at 100 kHz; reduces broadband noise from switching supplies and dimmer circuits in commercial electrical environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOUVS Over\/Under-Voltage Shutdown\u003c\/strong\u003e — Shuts down switched outlets when line voltage falls below 90V or exceeds 145V to protect AV equipment from brownout and overvoltage damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eICE Inrush Current Elimination\u003c\/strong\u003e — Actively manages inrush current at power-up, preventing circuit breaker trips and reducing capacitive stress on equipment power supply inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 1449 A-1-1 Rating\u003c\/strong\u003e — Tested to 1,000 surges at 6,000V \/ 3,000A with 170V measured suppressed voltage and zero failures; meets the highest UL 1449 Adjunct Endurance classification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Test Circuit with Visual Indicator\u003c\/strong\u003e — Front-panel LED confirms active protection status; alerts when the unit requires service attention.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20-Amp Load Rating\u003c\/strong\u003e — Supports the full current capacity of a dedicated 20-amp commercial branch circuit, suitable for fully populated AV racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetic Shielding Steel Enclosure\u003c\/strong\u003e — Reduces EMI radiation from the power distribution unit into adjacent audio and video equipment in the rack.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eHouse of worship\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-1120-RT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Rating\u003c\/td\u003e\n\u003ctd\u003e20A @ 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space\u003c\/td\u003e\n\u003ctd\u003e1U (1.75\" H x 19\" W x 10.5\" D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e11 lbs (5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlets\u003c\/td\u003e\n\u003ctd\u003e8 rear (6 switched, 2 always-on) + 1 front courtesy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement (no load)\u003c\/td\u003e\n\u003ctd\u003e15 watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Let-Through Voltage\u003c\/td\u003e\n\u003ctd\u003e0 volts (6,000V input surge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL 1449 Rating\u003c\/td\u003e\n\u003ctd\u003eA-1-1; 1,000 surges @ 6,000V \/ 3,000A, 170V suppressed, no failures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Guidelines\u003c\/td\u003e\n\u003ctd\u003eGrade A, Class 1, Mode 1 (CIDA-A-55818)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMI\/RFI Normal Mode (50-ohm)\u003c\/td\u003e\n\u003ctd\u003e40 dB @ 100 kHz; 50 dB @ 300 kHz; 50 dB @ 3 MHz; 50 dB @ 30 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMI\/RFI Common Mode (50-ohm)\u003c\/td\u003e\n\u003ctd\u003e18 dB @ 300 kHz; 30 dB @ 1 MHz; 50 dB @ 5 MHz; 50 dB @ 20 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUndervoltage Shutdown\u003c\/td\u003e\n\u003ctd\u003e90V (resumes at 100V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Shutdown\u003c\/td\u003e\n\u003ctd\u003e145V (resumes at 135V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote Turn-On Voltage Range\u003c\/td\u003e\n\u003ctd\u003e5–30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote Turn-On Current Draw\u003c\/td\u003e\n\u003ctd\u003eContact closure: 3 mA; 5V: 1 mA; 12V: 2.5 mA; 24V: 5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Relay Contact Rating\u003c\/td\u003e\n\u003ctd\u003e30V @ 1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Output\u003c\/td\u003e\n\u003ctd\u003e12V DC, 20 mA max (resistor required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e5–35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5–95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Listing\u003c\/td\u003e\n\u003ctd\u003eETL (UL 1449-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Cord\u003c\/td\u003e\n\u003ctd\u003e9 ft grounded 3-wire #12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003eWhat is the difference between the SX-1120-RT and the SX-1115-RT?\u003c\/dt\u003e\n\u003cdd\u003eThe SX-1120-RT is rated at 20 amps and the SX-1115-RT is rated at 15 amps. Both share the same outlet configuration, EMI\/RFI filtering, surge elimination technology, and remote turn-on capability. The 20-amp model is appropriate for fully loaded AV racks on dedicated 20-amp branch circuits; the 15-amp model suits lighter loads on standard 15-amp circuits.\u003c\/dd\u003e\n\u003cdt\u003eHow does the remote turn-on input work with a Crestron or AMX system?\u003c\/dt\u003e\n\u003cdd\u003eThe remote turn-on input accepts 5 to 30V DC or a dry contact closure. A relay output on a Crestron or AMX control processor can switch this input directly, allowing the control system to power the entire rack on or off as part of a room preset or scheduled event.\u003c\/dd\u003e\n\u003cdt\u003eWhat does zero let-through voltage mean in practice?\u003c\/dt\u003e\n\u003cdd\u003eZero let-through voltage means that during a surge event, no measurable overvoltage is passed through to the connected equipment. The SX-1120-RT was tested to 1,000 surges at 6,000V \/ 3,000A with a measured suppressed voltage of 170V and zero failures, confirming the Advanced Series Mode technology consistently prevents surge energy from reaching connected devices.\u003c\/dd\u003e\n\u003cdt\u003eHow does COUVS protect AV equipment from brownouts?\u003c\/dt\u003e\n\u003cdd\u003eCOUVS monitors line voltage in real time. If the voltage drops below 90V (indicative of a brownout) or rises above 145V (indicative of an overvoltage event or line fault), the unit immediately shuts down the six switched outlets. Once line voltage returns to a safe range, the outlets restore power automatically without manual intervention.\u003c\/dd\u003e\n\u003cdt\u003eDoes the SX-1120-RT eliminate the need for a separate power sequencer?\u003c\/dt\u003e\n\u003cdd\u003eThe SX-1120-RT includes remote turn-on capability but does not provide time-delayed sequential switching between outlet banks. For installations requiring ordered power-up across multiple device groups, the SurgeX SEQ or SEQ-1U should be used instead, or paired with the SX-1120-RT for protection and sequencing in combination.\u003c\/dd\u003e\n\u003cdt\u003eIs the SX-1120-RT appropriate for government facility installations?\u003c\/dt\u003e\n\u003cdd\u003eYes. The unit meets Grade A, Class 1, Mode 1 federal specifications under CIDA-A-55818, which are the most stringent government purchase requirements for branch circuit surge suppressors, and carries ETL listing to UL 1449-2.\u003c\/dd\u003e\n\u003cdt\u003eWhat does the self-test circuit do?\u003c\/dt\u003e\n\u003cdd\u003eThe self-test circuit continuously verifies that the Advanced Series Mode protection components are functioning. The front-panel visual indicator reflects the result; if protection is compromised, the indicator alerts the technician so the unit can be serviced before the installation is left unprotected.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":42273752482028,"sku":"SX-1120-RT","price":1389.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-sx-1120-rt-8-outlet-rackmount-surge-suppressor-power-conditioner-creation-networks-44908.png?v=1757888850"},{"product_id":"surgex-sx-1115-rt-8-outlet-surge-suppressor-and-power-conditioner","title":"SurgeX SX-1115-RT 8-Outlet Surge Suppressor and Power Conditioner","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-1115-RT is a 1U rack-mount, 15-amp power conditioner and surge suppressor with remote turn-on capability, engineered for commercial AV system integration in conference rooms, training rooms, and multi-purpose spaces. As a \u003cstrong\u003e15-amp rackmount power conditioner with remote turn-on\u003c\/strong\u003e, the SX-1115-RT provides eight rear-panel outlets and the same Advanced Series Mode surge elimination technology as the 20-amp SX-1120-RT, in a form factor sized for standard 15-amp commercial branch circuits. It carries the highest UL 1449 Adjunct Endurance classification (A-1-1) and meets federal Grade A, Class 1, Mode 1 specifications under CIDA-A-55818.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe SX-1115-RT delivers 15 amps at 120V through eight rear-panel grounded receptacles — six switched and two always-on — plus a front-panel courtesy outlet for local access during rack commissioning and service. The remote turn-on input accepts 5 to 30V DC or a contact closure, enabling direct integration with commercial AV control systems to bring the entire rack on and off as part of a room control preset.\u003c\/p\u003e\u003cp\u003eAdvanced Series Mode surge elimination technology provides zero let-through voltage on surge events up to 6,000 volts and handles unlimited surge current without degrading over time. Unlike conventional MOV-based designs that divert surge energy to the ground conductor and generate common-mode noise, Advanced Series Mode contains and dissipates the surge within the protection circuit, leaving the ground conductor clean and audio signal paths undisturbed.\u003c\/p\u003e\u003cp\u003eImpedance Tolerant EMI\/RFI filtering delivers greater than 30 dB of normal-mode attenuation from 80 kHz to 50 MHz, with peak attenuation of 75 dB at 3 MHz. This level of filtering is effective against the broadband switching noise generated by LED drivers, dimmer circuits, computer power supplies, and building HVAC systems that are commonly found on shared commercial branch circuits. Common-mode attenuation exceeds 30 dB from 700 kHz to 20 MHz, reducing differential noise between hot and neutral conductors that can degrade digital AV signal integrity.\u003c\/p\u003e\u003cp\u003eCOUVS over\/under-voltage shutdown circuitry monitors line voltage continuously and disconnects switched outlets when voltage goes outside safe operating parameters, protecting equipment from brownout and line fault damage. SurgeX ICE (Inrush Current Elimination) technology manages inrush current at power-up to prevent nuisance circuit breaker trips in installations where multiple devices in the rack draw simultaneously from a single 15-amp circuit. A self-test circuit with front-panel visual indicator provides ongoing confirmation that protection is active.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Turn-On Input\u003c\/strong\u003e — Accepts 5–30V DC or contact closure for direct integration with Crestron, AMX, Extron, and other commercial AV control processors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Series Mode Surge Elimination\u003c\/strong\u003e — Zero let-through voltage on surges up to 6,000V; no ground contamination or common-mode disturbances produced during suppression events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 Rear-Panel Outlets\u003c\/strong\u003e — Six switched and two always-on receptacles plus a front-panel courtesy outlet; supports full 15-amp load capacity of a dedicated branch circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpedance Tolerant EMI\/RFI Filtering\u003c\/strong\u003e — Greater than 30 dB normal-mode attenuation from 80 kHz to 50 MHz; effective against switching supply noise, LED dimmer interference, and HVAC motor harmonics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOUVS Over\/Under-Voltage Shutdown\u003c\/strong\u003e — Monitors line voltage and automatically disconnects switched outlets during brownout or overvoltage conditions to protect connected AV equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eICE Inrush Current Elimination\u003c\/strong\u003e — Manages inrush current at power-up to prevent nuisance circuit breaker trips on shared or fully loaded 15-amp commercial branch circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 1449 A-1-1 Rating\u003c\/strong\u003e — Tested to 1,000 surges at 6,000V \/ 3,000A with 170V measured suppressed voltage and zero failures; highest UL 1449 Adjunct Endurance classification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Test Circuit with Visual Indicator\u003c\/strong\u003e — Continuously verifies protection status; front-panel LED alerts when the unit requires attention.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Circuit Breaker Protection\u003c\/strong\u003e — Provides overload protection without replaceable fuses, restoring automatically after thermal cool-down.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetic Shielding Steel Enclosure\u003c\/strong\u003e — Reduces EMI radiation from the PDU into adjacent audio, video, and DSP equipment in the same rack.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eHuddle room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eAll-hands room\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-1115-RT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Rating\u003c\/td\u003e\n\u003ctd\u003e15A @ 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space\u003c\/td\u003e\n\u003ctd\u003e1U (1.75\" H x 19\" W x 10.5\" D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e11 lbs (5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlets\u003c\/td\u003e\n\u003ctd\u003e8 rear (6 switched, 2 always-on) + 1 front courtesy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement (no load)\u003c\/td\u003e\n\u003ctd\u003e15 watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Let-Through Voltage\u003c\/td\u003e\n\u003ctd\u003e0 volts (6,000V input surge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL 1449 Rating\u003c\/td\u003e\n\u003ctd\u003eA-1-1; 1,000 surges @ 6,000V \/ 3,000A, 170V suppressed, no failures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Guidelines\u003c\/td\u003e\n\u003ctd\u003eGrade A, Class 1, Mode 1 (CIDA-A-55818)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMI\/RFI Normal Mode (50-ohm)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;30 dB 80 kHz–50 MHz; 37 dB @ 100 kHz; 56 dB @ 300 kHz; 75 dB @ 3 MHz; 46 dB @ 30 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMI\/RFI Common Mode (50-ohm)\u003c\/td\u003e\n\u003ctd\u003e30 dB 700 kHz–20 MHz; 23 dB @ 300 kHz; 32 dB @ 1 MHz; 50 dB @ 5 MHz; 32 dB @ 20 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote Turn-On Voltage Range\u003c\/td\u003e\n\u003ctd\u003e5–30V DC or contact closure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e5–35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5–95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Listing\u003c\/td\u003e\n\u003ctd\u003eETL (UL 1449-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Cord\u003c\/td\u003e\n\u003ctd\u003e9 ft grounded 3-wire #12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003eWhat is the difference between the SX-1115-RT and the SX-1120-RT?\u003c\/dt\u003e\n\u003cdd\u003eThe SX-1115-RT is rated at 15 amps and the SX-1120-RT is rated at 20 amps. Both share the same outlet configuration, remote turn-on capability, EMI\/RFI filtering, and Advanced Series Mode surge elimination. The 15-amp model is appropriate for standard commercial branch circuits; the 20-amp model is used on dedicated 20-amp circuits supporting heavier AV rack loads.\u003c\/dd\u003e\n\u003cdt\u003eHow do I connect the remote turn-on to a Crestron control processor?\u003c\/dt\u003e\n\u003cdd\u003eConnect the relay output of the Crestron control card or expansion chassis to the remote turn-on terminal on the SX-1115-RT rear panel. The input accepts contact closures (3 mA) or applied DC voltages from 5 to 30V. No additional interface hardware or relay module is required.\u003c\/dd\u003e\n\u003cdt\u003eDoes the SX-1115-RT protect against brownouts as well as surges?\u003c\/dt\u003e\n\u003cdd\u003eYes. COUVS circuitry monitors line voltage continuously. If voltage falls below the undervoltage threshold or rises above the overvoltage threshold, the switched outlets are disconnected until voltage returns to within safe operating limits. This protects equipment from the sustained low-voltage conditions that cause motor overheating and power supply stress.\u003c\/dd\u003e\n\u003cdt\u003eHow does Impedance Tolerant EMI\/RFI filtering differ from standard filtering?\u003c\/dt\u003e\n\u003cdd\u003eConventional EMI filters are designed for a specific load impedance (typically 50 ohms) and their attenuation degrades significantly when connected to the varying impedance of real-world equipment. Impedance Tolerant filtering maintains consistent attenuation across a wide range of load impedances, making it effective regardless of what equipment is plugged into the outlets.\u003c\/dd\u003e\n\u003cdt\u003eWill the SX-1115-RT prevent circuit breaker trips in a shared-circuit installation?\u003c\/dt\u003e\n\u003cdd\u003eICE (Inrush Current Elimination) technology actively manages inrush current at power-up, which is the primary cause of nuisance circuit breaker trips when multiple devices power on simultaneously. For heavily loaded 15-amp circuits with multiple high-inrush devices, using the SurgeX SEQ-1U for sequenced power-up provides additional control over inrush distribution.\u003c\/dd\u003e\n\u003cdt\u003eDoes the SX-1115-RT require any programming or configuration?\u003c\/dt\u003e\n\u003cdd\u003eNo. The SX-1115-RT is a plug-and-protect device that requires no user programming. The remote turn-on input is wired during installation, and the unit operates automatically from that point forward. The self-test circuit monitors protection status continuously without any user interaction required.\u003c\/dd\u003e\n\u003cdt\u003eIs the SX-1115-RT manufactured in the United States?\u003c\/dt\u003e\n\u003cdd\u003eYes. The SX-1115-RT is manufactured in the U.S.A. and carries an ETL listing to UL 1449-2, confirming compliance with the applicable UL standard for surge protective devices.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":42273752645868,"sku":"SX-1115-RT","price":1159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-sx-1115-rt-8-outlet-surge-suppressor-and-power-conditioner-creation-networks-16877.png?v=1757888853"},{"product_id":"surgex-seq-1u-programmable-sequencer-surge-eliminator-8-outlets","title":"SurgeX SEQ-1U Programmable Sequencer Surge Eliminator, 8 Outlets","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SEQ-1U is a 1U rack-mount, 120V 20-amp programmable AC power sequencer built for commercial AV installations where rack space is at a premium. As a purpose-built \u003cstrong\u003e1U programmable AV power sequencer\u003c\/strong\u003e, it delivers the same three-bank power sequencing logic and Advanced Series Mode surge elimination as the full-size SEQ in a single rack space. It is the preferred choice for huddle rooms, smaller conference rooms, and AV-over-IP deployments where a compact, integrator-friendly sequencing solution is required without sacrificing protection quality or control system integration capability.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe SEQ-1U provides eight 120V rear-panel receptacles: two always-on outlets and six across three sequenced banks of varying size, with all programming accessible via the front panel. The 1U form factor makes it particularly well suited for compact AV racks in conference rooms, digital signage infrastructure closets, and smaller multi-zone audio systems where every rack unit counts but reliable power sequencing remains non-negotiable.\u003c\/p\u003e\u003cp\u003eLike its larger sibling, the SEQ-1U is microprocessor-controlled and stores all configuration in non-volatile memory, so sequencing parameters, voltage thresholds, and power-failure recovery behavior survive power outages without manual reprogramming. Setup is performed entirely from the front panel and all signal and power connections are made at the rear, simplifying installation and in-service adjustments.\u003c\/p\u003e\u003cp\u003eThe unit includes three remote control inputs compatible with DC voltages from 5 to 30V or contact closures, enabling direct integration with Crestron, AMX, Extron, and other building control platforms. A programmable 12V DC output can drive LEDs or a relay for visual confirmation, and the auxiliary relay output can be used to trigger or control other SurgeX products in the same installation. An optional password protects the programming against unauthorized modification.\u003c\/p\u003e\u003cp\u003eSurgeX Advanced Series Mode technology provides zero let-through voltage on surge events up to 6,000 volts, with no diversion to ground and no introduction of common-mode noise — both critical for installations where audio equipment is sharing the same power infrastructure. The unit carries a UL 1449 A-1-1 rating, the highest classification under UL Adjunct Endurance Testing, and meets federal Grade A, Class 1, Mode 1 specifications under CIDA-A-55818.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1U Rack-Mount Form Factor\u003c\/strong\u003e — Single rack space construction fits compact AV racks in conference rooms, huddle spaces, and infrastructure closets without sacrificing sequencing capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Sequenced Outlet Banks\u003c\/strong\u003e — Independently timed banks allow precise control of device power-up order to eliminate inrush current stacking and prevent audible pops at amplifier outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Series Mode Surge Elimination\u003c\/strong\u003e — Zero let-through voltage on surges up to 6,000V; no ground contamination or common-mode disturbances introduced into the system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo Always-On Outlets\u003c\/strong\u003e — Dedicated unswitched receptacles for network devices, DSPs, or other equipment that must remain powered independent of sequencing state.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Control Inputs\u003c\/strong\u003e — Three inputs accept 5–30V DC or contact closures for direct integration with Crestron, AMX, Extron, and similar AV control processors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable 12V DC Output\u003c\/strong\u003e — Drives LEDs or small relays for visual status indication or electromechanical confirmation feedback within the rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Volatile Memory\u003c\/strong\u003e — All programmed settings are retained through power outages; configurable for auto-restore or manual restart after a power failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePassword Protection\u003c\/strong\u003e — Up to six-character password locks the configuration against unauthorized changes in shared or public-access installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Relay Output\u003c\/strong\u003e — Provides a normally-open contact pair to control or cascade other SurgeX products within larger AV rack systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 1449 A-1-1 Rating\u003c\/strong\u003e — Highest available UL Adjunct Endurance Test classification, confirming sustained protection across 1,000 surges at 6,000V without failure.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eHuddle room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSEQ-1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Rating\u003c\/td\u003e\n\u003ctd\u003e20 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space\u003c\/td\u003e\n\u003ctd\u003e1U (1.75\" H x 19\" W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Outlets\u003c\/td\u003e\n\u003ctd\u003e8 (6 sequenced, 2 always-on)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSequenced Banks\u003c\/td\u003e\n\u003ctd\u003e3 banks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Let-Through Voltage\u003c\/td\u003e\n\u003ctd\u003e0 volts (6,000V input surge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL 1449 Rating\u003c\/td\u003e\n\u003ctd\u003eA-1-1 (Adjunct Endurance Test)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFederal Guidelines\u003c\/td\u003e\n\u003ctd\u003eGrade A, Class 1, Mode 1 (CIDA-A-55818)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e5–30V DC or contact closure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable DC Output\u003c\/td\u003e\n\u003ctd\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Relay\u003c\/td\u003e\n\u003ctd\u003eNormally-open contact pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile (NVRAM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eMagnetic shielding steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Cord\u003c\/td\u003e\n\u003ctd\u003e9 ft grounded 3-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003eHow does the SEQ-1U differ from the full-size SEQ?\u003c\/dt\u003e\n\u003cdd\u003eThe SEQ-1U occupies a single rack unit (1U) and provides eight outlets across three sequenced banks. The SEQ is a 2U unit with fourteen outlets. Both use identical Advanced Series Mode protection and the same remote control interface, but the SEQ-1U is better suited for compact rack configurations where space is constrained.\u003c\/dd\u003e\n\u003cdt\u003eCan the SEQ-1U control other devices in the rack via its relay output?\u003c\/dt\u003e\n\u003cdd\u003eYes. The auxiliary relay output provides a normally-open contact pair rated for low-voltage switching, which can be used to trigger other SurgeX products or small control relays within the same rack installation.\u003c\/dd\u003e\n\u003cdt\u003eIs the SEQ-1U compatible with Crestron and AMX control systems?\u003c\/dt\u003e\n\u003cdd\u003eYes. The three remote inputs accept DC voltages from 5 to 30V or contact closures, which are directly compatible with relay module outputs on Crestron, AMX, Extron, and similar commercial AV control processors.\u003c\/dd\u003e\n\u003cdt\u003eWhat is non-volatile memory and why does it matter for AV installations?\u003c\/dt\u003e\n\u003cdd\u003eNon-volatile memory retains all programming data — including time delays, voltage thresholds, and power-failure recovery settings — when the unit loses power. This eliminates the need to reprogram the sequencer after every power outage, which is especially important in unattended commercial installations.\u003c\/dd\u003e\n\u003cdt\u003eHow does Advanced Series Mode differ from MOV-based surge protection?\u003c\/dt\u003e\n\u003cdd\u003eMetal Oxide Varistor (MOV) designs divert surge current to ground, which can introduce common-mode noise and degrade over repeated surge events. Advanced Series Mode technology absorbs and dissipates surge energy within the protection circuit itself, providing zero let-through voltage without ground contamination and without degrading over time.\u003c\/dd\u003e\n\u003cdt\u003eWhat happens if the line voltage drops below an acceptable level?\u003c\/dt\u003e\n\u003cdd\u003eThe SEQ-1U includes adjustable under-voltage and over-voltage shutdown thresholds. If line voltage falls below the configured minimum or exceeds the maximum, the unit will shut down connected equipment to prevent damage, then automatically restore power once the line voltage returns to within acceptable limits.\u003c\/dd\u003e\n\u003cdt\u003eCan multiple SEQ-1U units be used together in a larger installation?\u003c\/dt\u003e\n\u003cdd\u003eYes. Two or more SEQ-1U units can be cascaded using the auxiliary relay output of one unit to trigger the remote input of the next, allowing coordinated multi-bank sequencing across a larger AV system.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":42273818280172,"sku":"SEQ-1U","price":1589.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-seq-1u-programmable-sequencer-surge-eliminator-8-outlets-creation-networks-95384.png?v=1757889200"},{"product_id":"surgex-ups-2000-ol-3ru-120v-20a-2000-va-ups-online-battery-backup-with-5x-outlets","title":"SurgeX UPS-2000-OL 3RU 120V\/20A 2000 VA UPS Online Battery Backup with 5x Outlets","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX UPS-2000-OL is a 2000VA online double conversion UPS that delivers network-grade, uninterrupted power to sensitive audio video systems, commercial IT infrastructure, and critical business equipment in a 3U rack-mount or tower form factor. Using true online double conversion technology, all power to connected devices is generated by the internal inverter at all times, providing zero transfer time when utility power is interrupted. Designed for AV system integration in conference rooms, boardrooms, and commercial meeting spaces, the UPS-2000-OL protects equipment with a 20A 120VAC input and five rear-panel outlets while offering runtime scalability from 7 minutes on internal batteries to 18 hours with external battery packs. It is a mid-range standalone online UPS suited for installations where a 3000VA unit exceeds load requirements but a smaller unit cannot adequately support the connected AV or IT rack.\u003c\/p\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-ups-2000-ol-3ru-120v20a-2000-va-ups-online-battery-backup-with-5x-outlets-creation-networks-35181.jpg?v=1757890108\" alt=\"SurgeX UPS-2000-OL 2000VA Online Double Conversion UPS 3RU Rack 120V 20A\" style=\"max-width:100%;height:auto;margin:16px 0;\"\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe UPS-2000-OL operates on a true online double conversion principle: incoming 120VAC is continuously rectified to DC, which both charges the internal battery bank and powers the inverter that supplies the output. Because the inverter is always active, there is no transfer time when utility power fails. The load transitions from utility-fed inverter operation to battery-fed inverter operation invisibly, with no interruption to signal processing, control systems, or data services. This makes the UPS-2000-OL appropriate for AV racks that include processors, scalers, DSPs, or control system controllers where even a sub-cycle power interruption could cause system resets.\u003c\/p\u003e\u003cp\u003eThe unit draws up to 16.6A on a 20A NEMA 5-20P input circuit and provides 2000VA (1400W) of output capacity through five rear-panel receptacles: one NEMA L5-20R and four NEMA 5-20R outlets. The controllable receptacle design allows individual outlet switching, which AV integrators can use to implement load sequencing — powering down non-critical devices like displays or peripheral systems to extend battery runtime for core signal path equipment during an outage.\u003c\/p\u003e\u003cp\u003eThe UPS-2000-OL installs in a standard 19-inch equipment rack in 3U (three rack units) of space, or stands alone as a tower unit. The unit ships with horizontal rack brackets, 5:1 rack brackets, a 6-foot DB9 serial cable, and the UPSILON UPS monitoring software on CD. The hot-swappable battery tray design allows field battery replacement without powering down the connected rack. An intuitive LCD screen on the front panel displays real-time input and output voltage, frequency, load level, and battery capacity, providing at-a-glance system status without requiring software access. An optional SNMP card enables network-based monitoring, integration with building management systems, and automated graceful shutdown for managed commercial AV environments. RS-232 communications are standard for serial-based monitoring and shutdown scripting.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnline Double Conversion Topology\u003c\/strong\u003e — Inverter is always active, providing zero transfer time during power outages and complete isolation from utility power quality issues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2000VA \/ 1400W Capacity\u003c\/strong\u003e — Mid-range capacity suited for 3U commercial AV and IT racks with signal processors, control systems, networking gear, and peripherals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue Sine-Wave Output\u003c\/strong\u003e — Compatible with active PFC power supplies in professional AV processors, amplifiers, and server-class hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControllable Receptacles\u003c\/strong\u003e — Individual outlet switching enables load sequencing and priority-based power management during battery operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable Battery Trays\u003c\/strong\u003e — Field battery replacement without system shutdown reduces service disruption in commercial conference room and boardroom installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScalable Runtime up to 18 Hours\u003c\/strong\u003e — Internal batteries provide 7-11 minutes of runtime; external battery packs (EBP2) extend runtime to 18 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3U Rack-Mount or Tower Form Factor\u003c\/strong\u003e — Includes hardware for both 19-inch rack and tower deployment for flexible AV and IT installation options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntuitive LCD Screen\u003c\/strong\u003e — Front-panel display shows input\/output voltage and frequency, operating mode, battery state, and load percentage in real time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional SNMP Network Card\u003c\/strong\u003e — Adds remote UPS monitoring, network management integration, and automated shutdown for managed AV system deployments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS-232 Communications (Standard)\u003c\/strong\u003e — Serial interface included for local monitoring and shutdown scripting via the bundled UPSILON software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power Factor Correction\u003c\/strong\u003e — Built-in input PFC minimizes harmonic distortion on the supply circuit and improves compatibility with generator backup power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto Restart\u003c\/strong\u003e — Automatically restores output power when utility power returns, without requiring manual intervention at the installation site.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room AV racks with DSPs, scalers, and control systems\u003c\/li\u003e\n\u003cli\u003eBoardroom presentation and videoconferencing infrastructure\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space AV equipment racks\u003c\/li\u003e\n\u003cli\u003eGovernment facility AV and IT infrastructure\u003c\/li\u003e\n\u003cli\u003eTraining room AV system power protection\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room AV and control system racks\u003c\/li\u003e\n\u003cli\u003eAll-hands room AV infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUPS-2000-OL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTopology\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTrue Online, Double Conversion, Input PF Correction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCapacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2000VA \/ 1400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120VAC (80-138V at 100% load; 60-138V at 40% load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eInput Frequency\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50\/60Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eInput Power Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e≥ 0.97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eRated Input Current\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e16.6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLine Cord\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eNEMA 5-20P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50\/60Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eSine wave, zero transfer time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLoad Power Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eEfficiency (AC\/DC\/AC)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e≥ 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOutlets\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e(1) NEMA L5-20R + (4) NEMA 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOverload Capacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e110-150% for 30 sec; ≥ 150% for 200 msec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCrest Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3:1 at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eAuto Restart\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eStart on Battery\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eBattery Type (UPS)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e(4) 12V 7.2AH \/ 48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eBackup Time (Internal)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7-11 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eExtended Battery Pack\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eEBP2 (up to 18 hours runtime)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eRecharge Time\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTypically \u0026lt; 4 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUnit Dimensions\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e17.3\" L x 3.39\" H x 20.2\" D (438 x 86 x 513mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUnit Weight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e65 lbs (29.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3U Rack-Mount or Tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eRS-232 standard; SNMP optional card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0-40°C (32-104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eAudible Noise\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u0026lt; 50 dBA at 1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eAltitude\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUp to 6,000 ft (1,830 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUL, cUL, FCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3 years electronics \/ 1 year batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eIncluded Accessories\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUPSILON CD, horizontal brackets, 5:1 brackets, manual, 6' DB9 cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003e\u003cstrong\u003eHow is online double conversion different from line interactive UPS technology?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eA line interactive UPS passes utility power directly to connected equipment during normal operation and switches to battery-derived output only when utility power deviates from acceptable limits, introducing a transfer delay of several milliseconds. The UPS-2000-OL’s double conversion design always runs connected equipment from the inverter, meaning there is no transfer event at all when utility power fails. This is the appropriate topology for AV processors, control systems, and IT servers that are sensitive to any power interruption.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat outlet types does the UPS-2000-OL provide?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eThe UPS-2000-OL provides five rear-panel outlets: one NEMA L5-20R twist-lock and four NEMA 5-20R standard outlets. The NEMA 5-20P input plug connects to a standard 20A 120VAC circuit. AV integrators should verify that the installation site has a dedicated 20A circuit available for this unit.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eCan runtime be extended beyond the internal battery capacity?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eYes. The UPS-2000-OL is compatible with the EBP2 extended battery pack, which can extend runtime from the 7-11 minute internal battery capacity to up to 18 hours. Multiple EBP2 units can be connected for progressively longer runtime. This is useful in applications requiring extended holdover during utility outages.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eDoes the UPS-2000-OL support network-based monitoring?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eYes, with the optional SNMP card (sold separately). The SNMP card enables monitoring via standard network management platforms and supports automated graceful shutdown scripting. The RS-232 interface is standard and works with the included UPSILON software for serial-based monitoring and management.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eCan batteries be replaced without shutting down connected equipment?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eYes. The UPS-2000-OL uses hot-swappable battery trays. Batteries can be removed and replaced while the unit remains powered and connected equipment operates normally. This minimizes service disruption in commercial AV installations where downtime is unacceptable during business hours.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat rack space does the UPS-2000-OL require?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eThe UPS-2000-OL occupies 3U in a standard 19-inch equipment rack. Unit dimensions are 17.3\" L x 3.39\" H x 20.2\" D and the unit weighs 65 lbs. It can also be configured as a tower unit. Rack structural load capacity should be verified before installation given the unit’s weight.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhere can I purchase the UPS-2000-OL and get technical support?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eThe SurgeX UPS-2000-OL is available through Creation Networks. For pricing, availability, compatibility questions, and commercial AV integration support, visit \u003ca href=\"https:\/\/creationnetworks.net\"\u003ecreationnetworks.net\u003c\/a\u003e.\u003c\/p\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":42451820216556,"sku":"UPS-2000-OL","price":3769.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-ups-2000-ol-3ru-120v20a-2000-va-ups-online-battery-backup-with-5x-outlets-creation-networks-35181.jpg?v=1757890108"},{"product_id":"surgex-ups-3000-ol-3ru-30a-3000va-5-outlet-standalone-battery-backup","title":"SurgeX UPS-3000-OL 3RU 30A 3000VA 5-Outlet Standalone Battery Backup","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX UPS-3000-OL is a 3000VA online double conversion UPS designed for mission-critical AV and IT installations where zero transfer time is required during a power event. Configured as a 3U rack-mount or tower unit, this commercial-grade battery backup delivers continuous true sine-wave power to sensitive audio video systems, data networks, and broadcast infrastructure by converting all incoming AC to DC and back to AC at all times. As a standalone online UPS for AV system integration, the UPS-3000-OL guarantees load continuity with absolutely no interruption when utility power fails, because the inverter is always active and the battery is always in the power path. With scalable runtime from 7 minutes on internal batteries up to 18 hours via external battery packs, the UPS-3000-OL serves commercial conference rooms, all-hands rooms, and broadcast studios with demanding power continuity requirements.\u003c\/p\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-ups-3000-ol-3ru-30a-3000va-5-outlet-standalone-battery-backup-creation-networks-15837.jpg?v=1757890109\" alt=\"SurgeX UPS-3000-OL 3000VA Online Double Conversion Standalone UPS 3RU Rack\" style=\"max-width:100%;height:auto;margin:16px 0;\"\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe UPS-3000-OL uses online double conversion topology, which means all power delivered to connected equipment is generated by the internal inverter at all times. Incoming utility AC is rectified to DC, which charges the battery bank and simultaneously powers the inverter. Because the inverter is always on and the battery is always in the DC bus, there is zero transfer time when utility power fails. The load never experiences the brief interruption present in line interactive designs, making this topology the correct choice for AV signal processors, computer-based control systems, and servers that are sensitive to even momentary power interruptions.\u003c\/p\u003e\u003cp\u003eThe UPS-3000-OL handles a 30A input circuit and delivers 3000VA (2100W) of output power through five rear-panel outlets: one NEMA L5-30R and four NEMA 5-20R receptacles. The controllable receptacles allow individual outlet management for load sequencing or selective shutdown of non-critical loads during battery operation. This level of control is useful in large conference room AV racks where prioritizing uptime for critical signal paths over peripheral devices extends effective battery runtime.\u003c\/p\u003e\u003cp\u003eRuntime scalability is a key advantage for large commercial deployments. The internal batteries provide 7 to 11 minutes at rated load. By connecting external battery packs (UPS-BPX-3000), runtime can be extended to 18 hours, enabling installations that require multi-hour power holdover for emergency broadcast, government facility continuity, or large auditorium AV systems. The hot-swappable battery trays allow field replacement without service shutdown. An intuitive LCD screen displays input and output voltage, frequency, battery capacity, and load level at a glance. An optional SNMP card adds network-based monitoring and automated shutdown capability for managed commercial AV deployments. The UPS-3000-OL ships with the UPSILON UPS monitoring software, horizontal rack brackets, and a 6-foot DB9 communications cable.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnline Double Conversion Topology\u003c\/strong\u003e — All power flows through the inverter continuously, providing zero transfer time when utility power fails and guaranteeing uninterrupted load operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue Sine-Wave Output\u003c\/strong\u003e — Clean 120VAC sine-wave output is compatible with active PFC power supplies in professional AV equipment, servers, and broadcast gear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3000VA \/ 2100W Capacity\u003c\/strong\u003e — Sufficient capacity for fully loaded 3U AV or IT rack installations including signal processors, control systems, switches, and peripherals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControllable Receptacles\u003c\/strong\u003e — Individual outlet control allows load sequencing, selective shutdown, and priority-based power management during battery operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable Battery Trays\u003c\/strong\u003e — Batteries can be replaced in the field without powering down connected equipment, reducing maintenance downtime in commercial installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScalable Runtime up to 18 Hours\u003c\/strong\u003e — Internal batteries provide 7-11 minutes; external battery packs extend runtime to 18 hours for mission-critical applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable as Tower or 19-Inch Rack Mount\u003c\/strong\u003e — Ships with hardware for both 3U rack installation and tower orientation for flexible deployment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntuitive LCD Screen\u003c\/strong\u003e — Displays input\/output voltage and frequency, operating mode, battery capacity, and load level without requiring external software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional SNMP Card\u003c\/strong\u003e — Enables remote UPS monitoring and management via network, plus automated graceful shutdown for managed AV and IT environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power Factor Correction\u003c\/strong\u003e — Built-in input PFC reduces harmonic current draw on the building electrical system and improves compatibility with generator power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS-232 and SNMP Communications\u003c\/strong\u003e — Standard RS-232 port included; SNMP card optional for network-based monitoring and enterprise UPS management integration.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room AV and videoconferencing infrastructure\u003c\/li\u003e\n\u003cli\u003eBoardroom AV systems with multiple signal processors\u003c\/li\u003e\n\u003cli\u003eAll-hands room and large meeting space AV racks\u003c\/li\u003e\n\u003cli\u003eBroadcast studio power protection\u003c\/li\u003e\n\u003cli\u003eGovernment facility AV and IT infrastructure\u003c\/li\u003e\n\u003cli\u003eAuditorium AV system power protection\u003c\/li\u003e\n\u003cli\u003eTraining room AV racks\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space rack installations\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUPS-3000-OL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTopology\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTrue Online, Double Conversion, Input PF Correction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCapacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3000VA \/ 2100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120VAC (80-138V at 100% load; 60-138V at 40% load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eInput Frequency\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50\/60Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eInput Power Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e≥ 0.97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eRated Input Current\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLine Cord\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eNEMA L5-30P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50\/60Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eSine wave, zero transfer time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLoad Power Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eEfficiency (AC\/DC\/AC)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e≥ 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eReceptacles\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e(1) NEMA L5-30R + (4) NEMA 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOverload Capacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e110-150% for 30 sec; ≥ 150% for 200 msec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCrest Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3:1 at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eAuto Restart\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eStart on Battery\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eBattery Type (UPS)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e(4) 12V 7.2AH \/ 48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eBackup Time (Internal)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e7-11 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eExtended Battery Pack\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUPS-BPX-3000 (up to 18 hours runtime)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eRecharge Time\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTypically \u0026lt; 4 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUnit Dimensions\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e17.3\" x 21.7\" x 5.2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUnit Weight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e81.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3U Rack-Mount or Tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eRS-232 standard; SNMP optional card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0-40°C (32-104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eAudible Noise\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u0026lt; 50 dBA at 1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eAltitude\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUp to 6,000 ft (1,830 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUL, cUL, FCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3 years electronics \/ 1 year batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eIncluded Accessories\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUPSILON CD, horizontal brackets, 5:1 brackets, manual, 6' DB9 cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat does online double conversion mean for AV system protection?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eOnline double conversion means the inverter is active at all times and all power to connected equipment is derived from the inverter, not directly from utility power. When utility power fails, there is zero transfer time because the load is already running from the inverter. This is the highest level of UPS protection and is appropriate for AV signal processors, control systems, and any equipment that cannot tolerate even a brief power interruption.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eHow does the UPS-3000-OL differ from a line interactive UPS?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eA line interactive UPS passes utility power directly to the load under normal conditions and only switches to battery\/inverter output when utility power falls outside acceptable limits, which introduces a brief transfer delay. The UPS-3000-OL’s double conversion design always runs the load through the inverter, eliminating this transfer gap. It also provides superior isolation from utility power quality issues including voltage fluctuations, frequency variations, and electrical noise.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eCan the UPS-3000-OL be monitored and managed over a network?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eYes, with the optional SNMP card installed. The SNMP interface integrates with network management systems and supports automated graceful shutdown. The standard RS-232 port is included and works with the supplied UPSILON UPS monitoring software for local or serial-connected monitoring.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eHow much runtime does the UPS-3000-OL provide?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eAt rated load, the internal batteries provide approximately 7-11 minutes of runtime. By connecting external battery packs (UPS-BPX-3000), runtime can be extended to up to 18 hours. Actual runtime depends on connected load; lighter loads will yield longer runtimes from internal batteries.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eAre the batteries field-replaceable without shutting down connected equipment?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eYes. The UPS-3000-OL uses hot-swappable battery trays that can be removed and replaced while the unit remains powered and connected equipment continues to operate. This is important for commercial installations where service shutdowns during business hours are disruptive.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat input plug does the UPS-3000-OL require?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eThe UPS-3000-OL ships with a NEMA L5-30P input plug, which requires a dedicated 30A 120VAC circuit. AV integrators should confirm that the installation site has a suitable circuit available before specifying this unit. The four NEMA 5-20R output receptacles and one NEMA L5-30R output are suitable for standard AV and IT equipment.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat is the warranty on the UPS-3000-OL?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eThe UPS-3000-OL carries a 3-year electronics warranty and a 1-year battery warranty from SurgeX. For purchasing, warranty support, and commercial AV integration assistance, contact Creation Networks at \u003ca href=\"https:\/\/creationnetworks.net\"\u003ecreationnetworks.net\u003c\/a\u003e.\u003c\/p\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":42451824836844,"sku":"UPS-3000-OL","price":4699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-ups-3000-ol-3ru-30a-3000va-5-outlet-standalone-battery-backup-creation-networks-15837.jpg?v=1757890109"},{"product_id":"surgex-ups-1440-li-iso-ups-w-isolation-transformer-1440va-120v-2u","title":"SurgeX UPS-1440-LI-ISO (58144-79R) – UPS w\/Isolation Transformer, 1440VA 120V 2U","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX UPS-1440-LI-ISO is a 1440VA line interactive UPS with integrated low impedance isolation transformer, purpose-built for commercial AV system integration and IT environments where clean, conditioned power is non-negotiable. Deployed as a 2U rack-mount unit or tower, this UPS provides reliable battery backup for conference room AV systems, boardroom presentation equipment, and broadcast control rooms. As a commercial-grade UPS with isolation transformer, the UPS-1440-LI-ISO delivers true sine-wave output and 0.9 power factor while simultaneously filtering electrical noise that standard UPS units pass through unchecked. AV integrators specifying power protection for sensitive audio video equipment will find the combination of line interactive battery backup and transformer-based power conditioning in a single 2U chassis particularly advantageous.\u003c\/p\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-ups-1440-li-iso-ups-wisolation-transformer-1440va-120v-2u-creation-networks-99062.png?v=1757892442\" alt=\"SurgeX UPS-1440-LI-ISO 1440VA Line Interactive UPS with Isolation Transformer 2U Rack\" style=\"max-width:100%;height:auto;margin:16px 0;\"\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe SurgeX UPS-1440-LI-ISO occupies a 2U rack space and ships ready to install in standard 19-inch equipment racks. Its steel and plastic enclosure houses a line interactive UPS topology that responds immediately to power outages, keeping connected AV and IT equipment running on clean battery-derived power until mains power is restored or equipment can be safely shut down. Eight grounded AC receptacles on the rear panel provide ample capacity for conference room AV racks with displays, signal processors, control systems, and network infrastructure.\u003c\/p\u003e\u003cp\u003eWhat distinguishes this unit from a standard rack UPS is the built-in low impedance isolation transformer. While the battery backup function handles outages and voltage irregularities, the isolation transformer continuously filters the AC supply, blocking high-frequency electrical noise, eliminating ground loops, and preventing harmful voltage harmonics from reaching downstream equipment. This dual-function design is especially valuable in commercial meeting spaces and government facilities where electrical infrastructure may introduce noise that degrades audio and video performance.\u003c\/p\u003e\u003cp\u003eThe UPS-1440-LI-ISO outputs a true sine wave at 0.9 power factor, making it compatible with active power factor correction (PFC) power supplies found in modern AV processors, amplifiers, and servers. The hot-swappable battery design allows maintenance technicians to replace the internal battery without powering down the connected system, reducing service disruption in mission-critical installations. An optional SNMP network card enables remote monitoring, automated shutdown scripting, and integration with network management platforms — a standard requirement in managed commercial AV and enterprise IT deployments. The advanced GUI interface provides on-site diagnostics without requiring external software. Battery tests can be scheduled automatically, ensuring readiness is confirmed without manual intervention. Additional battery cabinet options allow runtime extension for installations requiring extended holdover times beyond the internal battery capacity.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Interactive UPS Topology\u003c\/strong\u003e — Provides fast response to outages and voltage irregularities with minimal transfer time, protecting sensitive AV and IT equipment from power disruptions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Low Impedance Isolation Transformer\u003c\/strong\u003e — Continuously filters and conditions incoming AC power, eliminating electrical noise, ground loops, and harmonics that degrade AV system performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue Sine-Wave Output\u003c\/strong\u003e — Delivers clean 120VAC sine-wave power compatible with active PFC power supplies in professional AV processors, amplifiers, and servers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0.9 Output Power Factor\u003c\/strong\u003e — Higher power factor rating means more usable wattage relative to the VA rating compared to standard UPS units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable Battery\u003c\/strong\u003e — Internal battery can be replaced without shutting down connected equipment, minimizing downtime during scheduled maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2U Rack-Mount or Tower Form Factor\u003c\/strong\u003e — Installs in standard 19-inch AV and IT racks or stands alone as a tower unit for flexible deployment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 Rear-Panel Grounded AC Receptacles\u003c\/strong\u003e — Sufficient outlet count for fully populated conference room AV racks including displays, switchers, control processors, and networking gear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional SNMP Network Card\u003c\/strong\u003e — Enables remote UPS monitoring, automated shutdown, and integration with network management systems for managed AV installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto Battery Test\u003c\/strong\u003e — Scheduled automatic battery testing confirms readiness and flags battery degradation before a power event occurs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpandable Runtime\u003c\/strong\u003e — Compatible with additional external battery cabinets to extend autonomy beyond internal battery capacity for mission-critical applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBoardroom AV systems\u003c\/li\u003e\n\u003cli\u003eConference room AV and videoconferencing infrastructure\u003c\/li\u003e\n\u003cli\u003eGovernment facility AV and IT equipment rooms\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space rack installations\u003c\/li\u003e\n\u003cli\u003eBroadcast studio power protection\u003c\/li\u003e\n\u003cli\u003eTraining room AV racks\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room AV infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUPS-1440-LI-ISO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTopology\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLine Interactive with Low Impedance Isolation Transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCapacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1440VA \/ 1296W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOutput Power Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTrue Sine Wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eInput Connector\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e6-foot grounded 3-wire #14 line cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOutlets\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e8 grounded AC receptacles (rear panel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2U Rack-Mount or Tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e20.7\" D x 17.25\" W x 3.39\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e77 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eBattery\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eInternal maintenance-free, hot-swappable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCommunication\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOptional SNMP network card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eBattery Test\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eAuto scheduled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eRuntime Extension\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCompatible with additional external battery cabinets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat makes the UPS-1440-LI-ISO different from a standard rack UPS?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eThe UPS-1440-LI-ISO integrates a low impedance isolation transformer alongside the line interactive UPS circuitry. Standard UPS units protect against outages and voltage irregularities but do not filter high-frequency electrical noise or eliminate ground loops. The built-in isolation transformer continuously conditions the AC supply, making this unit appropriate for commercial AV installations where noise and harmonics affect audio and video quality.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eIs the UPS-1440-LI-ISO compatible with equipment that uses active PFC power supplies?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eYes. The unit outputs a true sine wave at 0.9 power factor, which is required for correct operation of active PFC power supplies. Many modern AV processors, server-class computers, and professional amplifiers use active PFC and will not operate correctly or reliably on simulated (stepped) sine wave UPS output.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eCan this UPS be monitored remotely as part of a managed AV system?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eYes, with the optional SNMP network card installed. The SNMP interface allows the UPS to be monitored and managed via standard network management platforms, supports automated graceful shutdown scripting, and is compatible with UPS monitoring software used in commercial AV and IT environments.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eHow is the battery replaced, and does replacement require a service shutdown?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eThe internal battery is hot-swappable, meaning it can be removed and replaced while the UPS remains energized and connected equipment continues to run on conditioned mains power. This is a significant advantage in commercial installations where downtime during business hours is not acceptable.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eCan runtime be extended beyond what the internal battery provides?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eYes. The UPS-1440-LI-ISO supports connection of additional external battery cabinets to extend autonomous runtime beyond the internal battery capacity. This is useful in installations requiring extended holdover for graceful shutdown of complex AV or IT systems.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat rack space does the UPS-1440-LI-ISO require?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eThe unit occupies 2U (two rack units) in a standard 19-inch equipment rack. It can also be used in tower orientation for non-rack deployments. Unit dimensions are 20.7\" D x 17.25\" W x 3.39\" H and the unit weighs 77 pounds, so rack structural ratings should be confirmed before installation.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat warranty and support does SurgeX provide for the UPS-1440-LI-ISO?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eSurgeX products are backed by manufacturer warranty coverage. For current warranty terms, authorized service options, and technical support for commercial AV installations, contact Creation Networks at \u003ca href=\"https:\/\/creationnetworks.net\"\u003ecreationnetworks.net\u003c\/a\u003e.\u003c\/p\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":42978971418860,"sku":"58144-79R","price":4189.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-ups-1440-li-iso-ups-wisolation-transformer-1440va-120v-2u-creation-networks-99062.png?v=1757892442"},{"product_id":"surgex-ups-1000-ol-2u-stand-alone-online-battery-backup-1000va","title":"SURGEX UPS-1000-OL 2U Stand-Alone Online Battery Backup (1000VA)","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX UPS-1000-OL is a 1000VA online double conversion UPS designed to provide continuous, uninterrupted power to sensitive AV equipment, critical business systems, and network infrastructure in a compact 2U rack-mount or tower form factor. As an entry-level standalone online UPS for AV system integration, the UPS-1000-OL delivers true sine-wave output with zero transfer time on a 15A 120VAC input circuit, making it appropriate for conference room AV racks, huddle room equipment, and smaller commercial meeting space installations. The online double conversion topology guarantees that connected equipment never experiences the brief power interruption inherent in line interactive designs, and the hot-swappable battery trays allow field maintenance without service shutdown. Runtime scalability from 7 minutes on internal batteries to 18 hours via external battery packs makes this unit viable for both standard AV protection and extended-holdover applications.\u003c\/p\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-ups-1000-ol-2u-stand-alone-online-battery-backup-1000va-creation-networks-21095.png?v=1757892443\" alt=\"SurgeX UPS-1000-OL 1000VA Online Double Conversion UPS 2U Rack Standalone\" style=\"max-width:100%;height:auto;margin:16px 0;\"\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe UPS-1000-OL operates on true online double conversion technology: all incoming 120VAC is rectified to DC, simultaneously charging the internal battery bank and powering the inverter that supplies connected equipment. The inverter is active at all times, so when utility power fails, the battery absorbs the DC bus load without any switching event. Connected AV processors, control systems, and network devices continue to operate without interruption, which is essential for installations where even a momentary power gap causes system resets or lost AV signal paths.\u003c\/p\u003e\u003cp\u003eAt 1000VA capacity with a standard NEMA 5-15P input plug, the UPS-1000-OL is well-suited for smaller AV racks and single-zone installations. It is the entry point in the SurgeX OL series and shares the same double conversion architecture as the 2000VA and 3000VA models. The controllable receptacle design allows individual outlet management, enabling AV integrators to sequence power or selectively shed non-critical loads during battery operation to extend effective runtime for the most important equipment in the rack.\u003c\/p\u003e\u003cp\u003eThe UPS-1000-OL installs in 2U of a standard 19-inch equipment rack or stands alone as a tower unit. It ships with horizontal rack brackets, 5:1 rack brackets, a 6-foot DB9 serial cable, and the UPSILON UPS monitoring software. An intuitive LED display on the front panel provides real-time visibility into operating mode, input and output voltage, battery charge level, and connected load percentage. The hot-swappable battery tray design means battery replacement does not require a service shutdown — batteries can be exchanged while the unit continues to power connected equipment. An optional SNMP card adds network-based monitoring and automated shutdown capability for managed commercial AV deployments. The RS-232 interface is standard and works with the included UPSILON software for local monitoring. External battery packs (UPS-BPX-1000) extend runtime significantly beyond the internal battery capacity, supporting applications where multi-hour holdover is required.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnline Double Conversion Topology\u003c\/strong\u003e — Inverter is always active, providing zero transfer time during utility power failures and full isolation from supply voltage variations and noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1000VA Capacity\u003c\/strong\u003e — Appropriate for conference room AV racks, huddle rooms, and single-zone commercial AV installations with moderate load requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue Sine-Wave Output\u003c\/strong\u003e — Clean sine-wave output is compatible with active PFC power supplies in modern AV processors, control systems, and network switches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControllable Receptacles\u003c\/strong\u003e — Individual outlet switching allows load prioritization and sequenced shutdown during battery operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable Battery Trays\u003c\/strong\u003e — Batteries are field-replaceable without powering down connected equipment, supporting zero-downtime maintenance in commercial installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScalable Runtime up to 18 Hours\u003c\/strong\u003e — Internal batteries provide rated backup time; external battery packs (UPS-BPX-1000) extend runtime to 18 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2U Rack-Mount or Tower Form Factor\u003c\/strong\u003e — Compact 2U chassis fits standard 19-inch AV and IT racks; tower configuration available for non-rack deployments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Status Display\u003c\/strong\u003e — Front-panel LED screen provides real-time operating mode, voltage, battery, and load information without requiring software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS-232 Communications (Standard)\u003c\/strong\u003e — Serial interface for local UPS monitoring and shutdown scripting using the included UPSILON software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional SNMP Card\u003c\/strong\u003e — Network-based monitoring and automated graceful shutdown for managed commercial AV and IT deployments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto Restart\u003c\/strong\u003e — Automatically restores output when utility power returns, reducing the need for on-site technician response after power events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart on Battery\u003c\/strong\u003e — Can be powered up from battery without utility power present, useful for mobile or temporary AV installations.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room AV racks\u003c\/li\u003e\n\u003cli\u003eHuddle room AV and videoconferencing equipment\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space AV infrastructure\u003c\/li\u003e\n\u003cli\u003eBoardroom control system power protection\u003c\/li\u003e\n\u003cli\u003eTraining room AV system protection\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room AV racks\u003c\/li\u003e\n\u003cli\u003eGovernment facility small AV equipment rooms\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"width:100%;border-collapse:collapse;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUPS-1000-OL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTopology\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTrue Online, Double Conversion, Input PF Correction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCapacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120VAC (80-138V at 100% load; 60-138V at 40% load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eInput Frequency\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50\/60Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eInput Power Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e≥ 0.97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLine Cord\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eNEMA 5-15P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e120VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50\/60Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eSine wave, zero transfer time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eLoad Power Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eEfficiency (AC\/DC\/AC)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e≥ 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eRated Input Current\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e12.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eReceptacles\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e(6) NEMA 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOverload Capacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e110-150% for 30 sec; ≥ 150% for 200 msec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCrest Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3:1 at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eAuto Restart\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eStart on Battery\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eBattery Type (UPS)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e(4) 12V 7.2AH \/ 48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eExtended Battery Pack\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUPS-BPX-1000 (up to 18 hours runtime)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eRecharge Time\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTypically \u0026lt; 4 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUnit Dimensions\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e17.3\" x 25.6\" x 3.4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUnit Weight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e57.3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2U Rack-Mount or Tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eRS-232 standard; SNMP optional card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e0-40°C (32-104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eAudible Noise\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e\u0026lt; 50 dBA at 1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eAltitude\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUp to 6,000 ft (1,830 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUL, cUL, FCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3 years electronics \/ 1 year batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eIncluded Accessories\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eUPSILON CD, horizontal brackets, 5:1 brackets, manual, 6' DB9 cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003e\u003cstrong\u003eIs the UPS-1000-OL appropriate for a conference room AV rack?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eYes. The UPS-1000-OL is designed for exactly this use case. It provides zero transfer time double conversion protection for AV processors, control system controllers, network switches, and display drivers in conference room and huddle room racks. At 1000VA capacity, it is well-matched for small to mid-size AV racks with moderate total connected load.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat is the difference between online double conversion and line interactive UPS technology?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eA line interactive UPS supplies utility power directly to connected equipment under normal conditions and transfers to battery-derived output only when utility power exceeds defined thresholds, which introduces a transfer gap. The UPS-1000-OL’s double conversion design always runs connected equipment from the inverter output. There is no transfer event when utility power fails, making it the correct choice for AV and control systems that are sensitive to even a sub-cycle power interruption.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eCan the UPS-1000-OL be monitored over a network?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eYes, with the optional SNMP card. The SNMP interface integrates with network management platforms and supports automated graceful shutdown. The RS-232 interface is standard and connects to the UPSILON monitoring software for serial-based management. For managed commercial AV deployments, the SNMP card is the recommended configuration.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eHow long does the UPS-1000-OL run on internal batteries?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eActual runtime depends on connected load. The internal batteries provide rated backup time for the connected load at the UPS’s rated capacity. Lighter loads yield proportionally longer runtime. External battery packs (UPS-BPX-1000) can extend runtime to up to 18 hours for applications requiring extended holdover.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eAre the batteries user-replaceable without a service shutdown?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eYes. The UPS-1000-OL uses hot-swappable battery trays. Batteries can be removed and replaced while the unit is energized and connected equipment continues to operate. Replacement batteries are available through Creation Networks.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat rack space does the UPS-1000-OL require?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eThe UPS-1000-OL occupies 2U in a standard 19-inch equipment rack. Unit dimensions are 17.3\" x 25.6\" x 3.4\" and the unit weighs 57.3 lbs. It can also be deployed in tower orientation for non-rack installations. Rack structural capacity should be verified before installation.\u003c\/p\u003e\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhere can I buy the SurgeX UPS-1000-OL and get support?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003e\u003cp\u003eThe UPS-1000-OL is available through Creation Networks. For current pricing, availability, and technical support for commercial AV installations, visit \u003ca href=\"https:\/\/creationnetworks.net\"\u003ecreationnetworks.net\u003c\/a\u003e.\u003c\/p\u003e\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":42978979348716,"sku":"UPS-1000-OL","price":2249.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/products\/surgex-ups-1000-ol-2u-stand-alone-online-battery-backup-1000va-creation-networks-21095.png?v=1757892443"},{"product_id":"surgex-sx-dpp-102-displaypak-power-management-system-120v-2-outlet","title":"SurgeX SX-DPP-102 DisplayPak+ Power Management System, 120V\/2-Outlet","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-DPP-102 is a compact IP-controlled power management system built for tight installations behind displays or on horizontal mounting surfaces. It pairs Advanced Series Mode surge elimination with remote power cycling, sequencing, and analytics over Wi-Fi or Ethernet, giving AV integrators a rack power management system that fits where a full rack strip won't. At roughly 1.75\" x 4\" x 7\", it mounts directly behind flat panels and digital signage without adding footprint to the install.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe DisplayPak+ was built around a simple problem: most IP-controlled power sequencers assume rack space that isn't available behind a wall-mounted display or in a lectern. The SX-DPP-102 configuration carries a 10A\/5-15P plug feeding 2 individually switchable 5-15R outlets, enough to sequence a display and a connected media player or soundbar without over-provisioning the circuit. Both Wi-Fi and Ethernet connectivity are built in, so the unit can join an existing AV network for remote monitoring without a dedicated home-run cable in every install. Advanced Series Mode surge protection and inline power filtration handle the electrical side, protecting connected displays and signal processors from surge events and line noise. On the control side, the DPP+ supports scheduled events, AutoPing device health checks, and threshold-triggered actions, so a technician can configure automatic resets for a frozen media player without a truck roll. Remote power analytics give facilities and AV service teams visibility into current draw per outlet, which helps flag a failing display or power supply before it causes a service call. Third-party integration with SurgeX CONNECT and standard control protocols means the DPP+ can report into an existing room control system rather than operating as an island. For AV system integration work in retail, corporate lobbies, and digital signage rollouts, that combination of small footprint and full IP control is the main draw over a standard rack PDU.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP-Controlled Connectivity\u003c\/strong\u003e — Access via Wi-Fi or Ethernet for seamless remote management of connected displays and devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndividually Switchable Receptacles\u003c\/strong\u003e — Cycle or schedule each outlet independently for targeted device control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Size\u003c\/strong\u003e — Approximately 1.75\" x 4\" x 7\", designed to fit tight spaces behind displays or on horizontal surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Power Analytics and Control\u003c\/strong\u003e — Turn on\/off, power cycle, and sequence connected equipment from anywhere on the network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Automation\u003c\/strong\u003e — Scheduled events, AutoPing device checks, and threshold-triggered controls reduce manual intervention.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Power Management\u003c\/strong\u003e — Remote monitoring and analytics support efficient day-to-day operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThird-Party Integration\u003c\/strong\u003e — Compatible with SurgeX CONNECT and other control systems for integration into existing AV networks.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eHuddle room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-DPP-102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Configuration\u003c\/td\u003e\n\u003ctd\u003e10A \/ 5-15P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Configuration\u003c\/td\u003e\n\u003ctd\u003e2 Outlets \/ 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Size (approx.)\u003c\/td\u003e\n\u003ctd\u003e1.75\" x 4\" x 7\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eWi-Fi, Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eAdvanced Series Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Integration\u003c\/td\u003e\n\u003ctd\u003eSurgeX CONNECT and third-party systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat control systems is the SX-DPP-102 compatible with?\u003c\/strong\u003e\u003cbr\u003eIt integrates with SurgeX CONNECT and standard third-party control protocols, so it can report into an existing room control processor rather than operating as a standalone device.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the SX-DPP-102 installed?\u003c\/strong\u003e\u003cbr\u003eIt mounts directly behind a display or on a horizontal surface using its compact 1.75\" x 4\" x 7\" enclosure, and connects to the network over Wi-Fi or Ethernet for remote management.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it require a network connection to function?\u003c\/strong\u003e\u003cbr\u003eBasic surge protection and outlet switching work without a network connection; Wi-Fi or Ethernet is required for remote monitoring, scheduling, and SurgeX CONNECT integration.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be integrated into an existing AV system?\u003c\/strong\u003e\u003cbr\u003eYes. Third-party integration support lets it report status and accept commands from an existing control system rather than requiring its own dedicated interface.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can assist with configuration, network integration, and troubleshooting for SurgeX power management products as part of a project scope of work.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official DisplayPak+ product page (ametekesp.com\/surgex).\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339699564780,"sku":"SX-DPP-102","price":399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/sxdpp102.jpg?v=1789009424"},{"product_id":"surgex-sx-dpp-104-displaypak-power-management-system-120v-4-outlet","title":"SurgeX SX-DPP-104 DisplayPak+ Power Management System, 120V\/4-Outlet","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-DPP-104 is a compact IP-controlled power management system built for tight installations behind displays or on horizontal mounting surfaces. It pairs Advanced Series Mode surge elimination with remote power cycling, sequencing, and analytics over Wi-Fi or Ethernet, giving AV integrators a rack power management system that fits where a full rack strip won't. At roughly 1.75\" x 4\" x 7\", it mounts directly behind flat panels and digital signage without adding footprint to the install.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe DisplayPak+ was built around a simple problem: most IP-controlled power sequencers assume rack space that isn't available behind a wall-mounted display or in a lectern. The SX-DPP-104 configuration carries a 10A\/5-15P plug feeding 4 individually switchable 5-15R outlets, giving enough switched capacity for a display, media player, soundbar, and a network switch on one compact unit. Both Wi-Fi and Ethernet connectivity are built in, so the unit can join an existing AV network for remote monitoring without a dedicated home-run cable in every install. Advanced Series Mode surge protection and inline power filtration handle the electrical side, protecting connected displays and signal processors from surge events and line noise. On the control side, the DPP+ supports scheduled events, AutoPing device health checks, and threshold-triggered actions, so a technician can configure automatic resets for a frozen media player without a truck roll. Remote power analytics give facilities and AV service teams visibility into current draw per outlet, which helps flag a failing display or power supply before it causes a service call. Third-party integration with SurgeX CONNECT and standard control protocols means the DPP+ can report into an existing room control system rather than operating as an island. For AV system integration work in retail, corporate lobbies, and digital signage rollouts, that combination of small footprint and full IP control is the main draw over a standard rack PDU.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP-Controlled Connectivity\u003c\/strong\u003e — Access via Wi-Fi or Ethernet for seamless remote management of connected displays and devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndividually Switchable Receptacles\u003c\/strong\u003e — Cycle or schedule each of the 4 outlets independently for targeted device control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Size\u003c\/strong\u003e — Approximately 1.75\" x 4\" x 7\", designed to fit tight spaces behind displays or on horizontal surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Power Analytics and Control\u003c\/strong\u003e — Turn on\/off, power cycle, and sequence connected equipment from anywhere on the network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Automation\u003c\/strong\u003e — Scheduled events, AutoPing device checks, and threshold-triggered controls reduce manual intervention.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Power Management\u003c\/strong\u003e — Remote monitoring and analytics support efficient day-to-day operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThird-Party Integration\u003c\/strong\u003e — Compatible with SurgeX CONNECT and other control systems for integration into existing AV networks.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eHuddle room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-DPP-104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Configuration\u003c\/td\u003e\n\u003ctd\u003e10A \/ 5-15P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Configuration\u003c\/td\u003e\n\u003ctd\u003e4 Outlets \/ 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Size (approx.)\u003c\/td\u003e\n\u003ctd\u003e1.75\" x 4\" x 7\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eWi-Fi, Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eAdvanced Series Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Integration\u003c\/td\u003e\n\u003ctd\u003eSurgeX CONNECT and third-party systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat control systems is the SX-DPP-104 compatible with?\u003c\/strong\u003e\u003cbr\u003eIt integrates with SurgeX CONNECT and standard third-party control protocols, so it can report into an existing room control processor rather than operating as a standalone device.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the SX-DPP-104 installed?\u003c\/strong\u003e\u003cbr\u003eIt mounts directly behind a display or on a horizontal surface using its compact 1.75\" x 4\" x 7\" enclosure, and connects to the network over Wi-Fi or Ethernet for remote management.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it require a network connection to function?\u003c\/strong\u003e\u003cbr\u003eBasic surge protection and outlet switching work without a network connection; Wi-Fi or Ethernet is required for remote monitoring, scheduling, and SurgeX CONNECT integration.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be integrated into an existing AV system?\u003c\/strong\u003e\u003cbr\u003eYes. Third-party integration support lets it report status and accept commands from an existing control system rather than requiring its own dedicated interface.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can assist with configuration, network integration, and troubleshooting for SurgeX power management products as part of a project scope of work.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official DisplayPak+ product page (ametekesp.com\/surgex).\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339699794156,"sku":"SX-DPP-104","price":449.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/sxdpp104.jpg?v=1789009430"},{"product_id":"surgex-sx-ap-129-axess-power-management-system-120v-15a","title":"SurgeX SX-AP-129 Axess+ Power Management System, 120V\/15A","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-AP-129 is a 1U rack-mount IP-controlled PDU built for AV and IT racks that need remote power control without a dedicated power management platform. It combines Advanced Series Mode surge elimination, current monitoring, and remote power cycling in a single rack space, giving integrators an IP-controlled power management system for conference rooms, equipment closets, and broadcast racks.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe Axess+ line targets a common gap in commercial AV racks: surge protection alone doesn't give a technician any way to remotely diagnose or reset a hung device. The SX-AP-129 carries a 12A\/5-15P plug feeding 9 total NEMA outlets, 8 of them individually switchable plus a front service outlet, on a 1U chassis. Every switched outlet supports remote turn on\/off, power cycling, and sequencing, so a stuck codec or switch can be power-cycled from a network operations center instead of a site visit. Built-in current monitoring and remote power analytics give facilities teams visibility into per-outlet draw, useful for catching a failing power supply before it takes down a room. Advanced scheduling, AutoPing device checks, and threshold-triggered events let the unit take automated action — resetting a frozen device on a schedule or when a ping check fails — without a technician watching the dashboard. The swappable, locking power cord keeps the unit secure in high-traffic racks where cords get bumped. Integration with SurgeX CONNECT extends that same control and analytics to a cloud dashboard, and the PDU integrates with third-party control systems rather than operating as a standalone device. For rack-mount power management system deployments in conference rooms, control rooms, and IT closets, that combination of surge protection and remote diagnostics is the main reason integrators spec Axess+ over a passive PDU.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP-Controlled PDU\u003c\/strong\u003e — Full remote management over the network, without requiring physical access to the rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Series Mode\u003c\/strong\u003e — Non-sacrificial surge elimination protects connected AV and IT equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndividually Switchable Receptacles\u003c\/strong\u003e — 8 of 9 outlets can be turned on\/off or cycled independently.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwappable Power Cord with Lock\u003c\/strong\u003e — Secures the power connection in racks with frequent access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Turn On\/Off, Power Cycling, and Sequencing\u003c\/strong\u003e — Reset or sequence connected devices without a site visit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Scheduling, AutoPing, and Threshold-Triggered Events\u003c\/strong\u003e — Automates resets and alerts based on schedule or device health checks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Power Management and Analytics\u003c\/strong\u003e — Per-outlet current monitoring supports proactive maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurgeX CONNECT Integration\u003c\/strong\u003e — Extends control and analytics to SurgeX's cloud-based platform and third-party control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-AP-129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Size\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Configuration\u003c\/td\u003e\n\u003ctd\u003e12A \/ 5-15P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Configuration\u003c\/td\u003e\n\u003ctd\u003e9 Outlets \/ 5-15R (8 switchable, 1 front service outlet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eAdvanced Series Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eIP-controlled; SurgeX CONNECT and third-party integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat control systems does the SX-AP-129 work with?\u003c\/strong\u003e\u003cbr\u003eIt integrates with SurgeX CONNECT and standard third-party control systems, allowing it to report status and accept commands from an existing rack or room controller.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the SX-AP-129 installed?\u003c\/strong\u003e\u003cbr\u003eIt mounts in a single rack unit (1U) and connects to the network for remote control; the swappable locking power cord secures the incoming power connection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan outlets be scheduled or automated?\u003c\/strong\u003e\u003cbr\u003eYes. Advanced scheduling, AutoPing device checks, and threshold-triggered events let the unit take automated action without manual intervention.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it require network access to provide surge protection?\u003c\/strong\u003e\u003cbr\u003eNo. Advanced Series Mode surge protection is always active; network connectivity is only required for remote control, monitoring, and SurgeX CONNECT integration.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can assist with configuration, network integration, and troubleshooting for SurgeX power management products as part of a project scope of work.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official Axess+ product page (ametekesp.com\/surgex).\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339699990764,"sku":"SX-AP-129","price":1529.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/surgex-sx-ap-129-power-management-system-front-three-quarter.jpg?v=1789078364"},{"product_id":"surgex-sx-ap-169-axess-power-management-system-120v","title":"SurgeX SX-AP-169 Axess+ Power Management System, 120V","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-AP-169 is a 1U rack-mount IP-controlled PDU built for higher-current AV and IT racks that need remote power control without a dedicated power management platform. It combines Advanced Series Mode surge elimination, current monitoring, and remote power cycling in a single rack space, giving integrators an IP-controlled power management system for conference rooms, equipment closets, and broadcast racks.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe Axess+ line targets a common gap in commercial AV racks: surge protection alone doesn't give a technician any way to remotely diagnose or reset a hung device. The SX-AP-169 steps up to a 16A\/5-20P plug feeding a mixed outlet bank of 7 outlets at 5-15R and 2 outlets at 5-20R, suited to racks mixing standard AV gear with higher-draw 20A equipment. Every switched outlet supports remote turn on\/off, power cycling, and sequencing, so a stuck codec or switch can be power-cycled from a network operations center instead of a site visit. Built-in current monitoring and remote power analytics give facilities teams visibility into per-outlet draw, useful for catching a failing power supply before it takes down a room. Advanced scheduling, AutoPing device checks, and threshold-triggered events let the unit take automated action — resetting a frozen device on a schedule or when a ping check fails — without a technician watching the dashboard. The swappable, locking power cord keeps the unit secure in high-traffic racks where cords get bumped. Integration with SurgeX CONNECT extends that same control and analytics to a cloud dashboard, and the PDU integrates with third-party control systems rather than operating as a standalone device. For rack-mount power management system deployments in conference rooms, control rooms, and IT closets running mixed-amperage equipment, that combination of surge protection and remote diagnostics is the main reason integrators spec Axess+ over a passive PDU.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP-Controlled PDU\u003c\/strong\u003e — Full remote management over the network, without requiring physical access to the rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Series Mode\u003c\/strong\u003e — Non-sacrificial surge elimination protects connected AV and IT equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndividually Switchable Receptacles\u003c\/strong\u003e — Switched outlets can be turned on\/off or cycled independently.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwappable Power Cord with Lock\u003c\/strong\u003e — Secures the power connection in racks with frequent access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Turn On\/Off, Power Cycling, and Sequencing\u003c\/strong\u003e — Reset or sequence connected devices without a site visit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Scheduling, AutoPing, and Threshold-Triggered Events\u003c\/strong\u003e — Automates resets and alerts based on schedule or device health checks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Power Management and Analytics\u003c\/strong\u003e — Per-outlet current monitoring supports proactive maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurgeX CONNECT Integration\u003c\/strong\u003e — Extends control and analytics to SurgeX's cloud-based platform and third-party control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-AP-169\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Size\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Configuration\u003c\/td\u003e\n\u003ctd\u003e16A \/ 5-20P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Configuration\u003c\/td\u003e\n\u003ctd\u003e7 Outlets \/ 5-15R + 2 Outlets \/ 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eAdvanced Series Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eIP-controlled; SurgeX CONNECT and third-party integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat control systems does the SX-AP-169 work with?\u003c\/strong\u003e\u003cbr\u003eIt integrates with SurgeX CONNECT and standard third-party control systems, allowing it to report status and accept commands from an existing rack or room controller.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the SX-AP-169 installed?\u003c\/strong\u003e\u003cbr\u003eIt mounts in a single rack unit (1U) and connects to the network for remote control; the swappable locking power cord secures the incoming power connection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan outlets be scheduled or automated?\u003c\/strong\u003e\u003cbr\u003eYes. Advanced scheduling, AutoPing device checks, and threshold-triggered events let the unit take automated action without manual intervention.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it support mixed 15A and 20A equipment?\u003c\/strong\u003e\u003cbr\u003eYes. The 5-15R and 5-20R outlet mix lets a single rack run both standard AV gear and 20A-rated equipment from one PDU.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can assist with configuration, network integration, and troubleshooting for SurgeX power management products as part of a project scope of work.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official Axess+ product page (ametekesp.com\/surgex).\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339700154604,"sku":"SX-AP-169","price":1599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/sxap169.jpg?v=1789010672"},{"product_id":"surgex-sx-aep-159-axess-elite-power-management-system-120v-12a-1ru","title":"SurgeX SX-AEP-159 Axess ELITE+ Power Management System, 120V\/12A, 1RU","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-AEP-159 is a 1RU IP-controlled power management system built for AV and IT racks that need remote scheduling, analytics, and third-party control integration in one unit. It pairs Advanced Series Mode surge protection with in-rush current elimination, giving integrators a rack power management system for control rooms, broadcast racks, and multi-room AV deployments that already run on a control platform.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe Axess ELITE+ line is built to integrate directly with existing control systems rather than operate as a standalone power strip. The SX-AEP-159 carries a 12A\/5-15P plug feeding 9 individually switchable 5-15R outlets, each reporting current draw for remote power analytics. Auxiliary relays and contact closure inputs let the unit tie into other room automation, such as triggering a screen drop or signaling an occupancy state, and Ethernet or RS-232 connectivity covers both modern IP-based control rooms and legacy serial-controlled racks. An external temperature and humidity sensor input adds environmental monitoring for equipment closets without a separate sensor package. In-rush current elimination (ICE) prevents the power draw spike that happens when several devices power up simultaneously from taking down a circuit breaker — a common failure mode in multi-display racks. The swappable, locking power cord and locking on\/off switch address physical security in shared or public-facing spaces. Scalable control means a single dashboard can manage multiple ELITE+ units across a facility, and SurgeX CONNECT integration extends that control and analytics to the cloud. For AV system integration work where power management needs to plug into an existing control processor rather than run as a separate system, that third-party integration is the main reason to spec Axess ELITE+ over a standalone PDU.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP-Controlled, Individually Switchable Outlets with Power Analytics\u003c\/strong\u003e — Remote control and per-outlet current monitoring from a network dashboard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Relays and Contact Closure\u003c\/strong\u003e — Trigger or respond to other room automation equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet or RS-232 Compatible\u003c\/strong\u003e — Integrates with modern IP control systems or legacy serial-based control processors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Temperature and Humidity Sensor\u003c\/strong\u003e — Adds environmental monitoring for equipment closets and racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScalable Control\u003c\/strong\u003e — Manage multiple units from a single dashboard across a facility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwappable Power Cord with Lock\u003c\/strong\u003e — Secures the power connection in high-traffic or public-facing racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking On\/Off Switch\u003c\/strong\u003e — Prevents accidental or unauthorized power shutoff.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThird-Party Integration\u003c\/strong\u003e — Works with SurgeX CONNECT and other control platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-AEP-159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Size\u003c\/td\u003e\n\u003ctd\u003e1RU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Configuration\u003c\/td\u003e\n\u003ctd\u003e12A \/ 5-15P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Configuration\u003c\/td\u003e\n\u003ctd\u003e9 Outlets \/ 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eAdvanced Series Mode with In-Rush Current Elimination (ICE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Interfaces\u003c\/td\u003e\n\u003ctd\u003eEthernet, RS-232, auxiliary relays, contact closure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensors\u003c\/td\u003e\n\u003ctd\u003eExternal temperature and humidity sensor input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat control systems does the SX-AEP-159 integrate with?\u003c\/strong\u003e\u003cbr\u003eIt supports Ethernet or RS-232 connections, auxiliary relays, and contact closure, so it integrates with both modern IP control processors and legacy serial-based systems, plus SurgeX CONNECT.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the SX-AEP-159 installed?\u003c\/strong\u003e\u003cbr\u003eIt mounts in a single rack space (1RU) with a swappable, locking power cord, and connects to a control system over Ethernet, RS-232, or contact closure as needed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it monitor environmental conditions in the rack?\u003c\/strong\u003e\u003cbr\u003eYes, via an external temperature and humidity sensor input, which reports alongside the unit's power analytics.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan multiple units be managed from one dashboard?\u003c\/strong\u003e\u003cbr\u003eYes. Scalable control allows a single dashboard to manage multiple Axess ELITE+ units across a facility.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can assist with configuration, control system integration, and troubleshooting for SurgeX power management products as part of a project scope of work.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official Axess ELITE+ product page (ametekesp.com\/surgex).\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339700351212,"sku":"SX-AEP-159","price":2899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/sxaep159.jpg?v=1789010689"},{"product_id":"surgex-sx-aep-209-axess-elite-power-management-system-120v-1ru","title":"SurgeX SX-AEP-209 Axess ELITE+ Power Management System, 120V, 1RU","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-AEP-209 is a 1RU IP-controlled power management system built for higher-current AV and IT racks that need remote scheduling, analytics, and third-party control integration in one unit. It pairs Advanced Series Mode surge protection with in-rush current elimination, giving integrators a rack power management system for control rooms, broadcast racks, and multi-room AV deployments that already run on a control platform.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe Axess ELITE+ line is built to integrate directly with existing control systems rather than operate as a standalone power strip. The SX-AEP-209 steps up to a 16A\/5-20P plug feeding a mixed bank of 7 outlets at 5-15R and 2 outlets at 5-20R, each reporting current draw for remote power analytics. Auxiliary relays and contact closure inputs let the unit tie into other room automation, such as triggering a screen drop or signaling an occupancy state, and Ethernet or RS-232 connectivity covers both modern IP-based control rooms and legacy serial-controlled racks. An external temperature and humidity sensor input adds environmental monitoring for equipment closets without a separate sensor package. In-rush current elimination (ICE) prevents the power draw spike that happens when several devices power up simultaneously from taking down a circuit breaker — a common failure mode in multi-display racks running mixed-amperage gear. The swappable, locking power cord and locking on\/off switch address physical security in shared or public-facing spaces. Scalable control means a single dashboard can manage multiple ELITE+ units across a facility, and SurgeX CONNECT integration extends that control and analytics to the cloud. For AV system integration work where power management needs to plug into an existing control processor rather than run as a separate system, that third-party integration is the main reason to spec Axess ELITE+ over a standalone PDU.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP-Controlled, Individually Switchable Outlets with Power Analytics\u003c\/strong\u003e — Remote control and per-outlet current monitoring from a network dashboard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Relays and Contact Closure\u003c\/strong\u003e — Trigger or respond to other room automation equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet or RS-232 Compatible\u003c\/strong\u003e — Integrates with modern IP control systems or legacy serial-based control processors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Temperature and Humidity Sensor\u003c\/strong\u003e — Adds environmental monitoring for equipment closets and racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScalable Control\u003c\/strong\u003e — Manage multiple units from a single dashboard across a facility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwappable Power Cord with Lock\u003c\/strong\u003e — Secures the power connection in high-traffic or public-facing racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocking On\/Off Switch\u003c\/strong\u003e — Prevents accidental or unauthorized power shutoff.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThird-Party Integration\u003c\/strong\u003e — Works with SurgeX CONNECT and other control platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-AEP-209\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Size\u003c\/td\u003e\n\u003ctd\u003e1RU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Configuration\u003c\/td\u003e\n\u003ctd\u003e16A \/ 5-20P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Configuration\u003c\/td\u003e\n\u003ctd\u003e7 Outlets \/ 5-15R + 2 Outlets \/ 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eAdvanced Series Mode with In-Rush Current Elimination (ICE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Interfaces\u003c\/td\u003e\n\u003ctd\u003eEthernet, RS-232, auxiliary relays, contact closure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensors\u003c\/td\u003e\n\u003ctd\u003eExternal temperature and humidity sensor input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat control systems does the SX-AEP-209 integrate with?\u003c\/strong\u003e\u003cbr\u003eIt supports Ethernet or RS-232 connections, auxiliary relays, and contact closure, so it integrates with both modern IP control processors and legacy serial-based systems, plus SurgeX CONNECT.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the SX-AEP-209 installed?\u003c\/strong\u003e\u003cbr\u003eIt mounts in a single rack space (1RU) with a swappable, locking power cord, and connects to a control system over Ethernet, RS-232, or contact closure as needed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it monitor environmental conditions in the rack?\u003c\/strong\u003e\u003cbr\u003eYes, via an external temperature and humidity sensor input, which reports alongside the unit's power analytics.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it support mixed 15A and 20A equipment?\u003c\/strong\u003e\u003cbr\u003eYes. The 5-15R and 5-20R outlet mix lets a single rack run both standard AV gear and 20A-rated equipment from one unit.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can assist with configuration, control system integration, and troubleshooting for SurgeX power management products as part of a project scope of work.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official Axess ELITE+ product page (ametekesp.com\/surgex).\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339700515052,"sku":"SX-AEP-209","price":2999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/sxaep209.jpg?v=1789010697"},{"product_id":"surgex-pf-420-branch-circuit-power-filter-120v","title":"SurgeX PF-420 Branch Circuit Power Filter, 120V","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX PF-420 is a whole-room branch circuit surge protector installed at the service panel, sub-panel, or load center rather than at individual outlets. It's built for AV integrators who need guaranteed surge protection across an entire room or building branch — conference centers, broadcast facilities, and mission-critical AV installs — instead of relying on protection at each rack or display.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003ePoint-of-use surge protectors only cover what's plugged into them; a branch circuit device like the PF-420 protects everything downstream of the panel it's installed at. The PF-420 is configured for (4) 20A\/120V circuits feeding an 80-amp load center, giving whole-room coverage for a space with multiple AV racks, displays, or a full control room on a shared electrical branch. It's built in a NEMA magnetic shielding steel enclosure that meets code for installation at the service entrance, sub-panels, and inside ceiling plenums — a common requirement in commercial and government AV projects where the electrical contractor needs a listed enclosure. Advanced Series Mode surge elimination and power conditioning handle the electrical side: surge energy is eliminated at the source without producing the ground contamination or common-mode disturbances that come with older MOV-based protection. An all-mode, impedance-tolerant EMI\/RFI filter further cleans the branch circuit, which matters for audio and video signal integrity in rooms with a lot of switched-mode power supplies on the same circuit. Because the PF-420 protects at the panel rather than the outlet, it's typically specified during electrical rough-in on new construction or a full AV room renovation, coordinated with the electrical contractor rather than installed by the AV integrator alone.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhole-Room Surge Protection\u003c\/strong\u003e — Protects every downstream circuit from a single panel-level installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNEMA Magnetic Shielding Steel Enclosure\u003c\/strong\u003e — Meets code for service entrance, sub-panel, and ceiling plenum installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Series Mode Surge Elimination\u003c\/strong\u003e — Eliminates surge energy without ground contamination or common-mode disturbances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-Mode Impedance Tolerant EMI\/RFI Filter\u003c\/strong\u003e — Reduces electrical noise across the branch circuit for cleaner AV signal performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e80 Amp Load Center\u003c\/strong\u003e — Supports four 20A\/120V circuits for multi-rack or multi-room branch protection.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePF-420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Configuration\u003c\/td\u003e\n\u003ctd\u003e(4) 20A \/ 120V circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Spec\u003c\/td\u003e\n\u003ctd\u003e(4) 20 Amp circuits, 80 Amp load center\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA magnetic shielding steel; rated for service entrance, sub-panel, and ceiling plenum installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eAdvanced Series Mode with all-mode impedance tolerant EMI\/RFI filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegion\u003c\/td\u003e\n\u003ctd\u003eFor use in the U.S. and Canada only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eIs the PF-420 compatible with a standard electrical service panel?\u003c\/strong\u003e\u003cbr\u003eYes, it's built in a NEMA magnetic shielding steel enclosure rated for installation at the service entrance, sub-panel, or load center.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWho typically installs the PF-420?\u003c\/strong\u003e\u003cbr\u003eBecause it's a panel-level device, it's usually installed by the electrical contractor during rough-in, coordinated with the AV integrator's project scope.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it protect equipment plugged in downstream automatically?\u003c\/strong\u003e\u003cbr\u003eYes. Once installed at the panel, every circuit downstream of the PF-420 receives Advanced Series Mode surge protection without additional point-of-use devices.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be installed in a ceiling plenum?\u003c\/strong\u003e\u003cbr\u003eYes, the enclosure is rated for ceiling plenum installation in addition to service entrance and sub-panel locations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide during installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can coordinate with your electrical contractor on panel-level surge protection specification as part of a project scope of work.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official Branch Circuit product page (ametekesp.com\/surgex).\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339700646124,"sku":"PF-420","price":3759.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/pf420.jpg?v=1789010706"},{"product_id":"surgex-sx-20ne-rt-branch-circuit-surge-eliminator-120v","title":"SurgeX SX-20NE-RT Branch Circuit Surge Eliminator, 120V","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-20NE-RT is a single-circuit branch surge protector installed at the service panel, sub-panel, or load center to protect one 20A\/120V circuit rather than an individual outlet. It's built for AV integrators who need guaranteed surge protection at the panel level for a single room or branch — a smaller conference room, a single-rack install, or a dedicated circuit feeding sensitive AV equipment.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003ePoint-of-use surge protectors only cover what's plugged into them; a branch circuit device like the SX-20NE-RT protects everything downstream of the panel it's installed at. The SX-20NE-RT is configured for a single 20A\/120V circuit, making it the right-sized option when a full multi-circuit load center like the PF-420 is more capacity than a project needs — for example, a single dedicated AV circuit in a smaller conference room or huddle space. It's built in a NEMA magnetic shielding steel enclosure that meets code for installation at the service entrance, sub-panels, and inside ceiling plenums, a common requirement in commercial and government AV projects where the electrical contractor needs a listed enclosure. Advanced Series Mode surge elimination and power conditioning handle the electrical side: surge energy is eliminated at the source without producing the ground contamination or common-mode disturbances that come with older MOV-based protection. An all-mode, impedance-tolerant EMI\/RFI filter further cleans the circuit, which matters for audio and video signal integrity on circuits shared with switched-mode power supplies. Because the SX-20NE-RT protects at the panel rather than the outlet, it's typically specified during electrical rough-in on new construction or a room renovation, coordinated with the electrical contractor rather than installed by the AV integrator alone.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-Circuit Branch Protection\u003c\/strong\u003e — Protects one 20A\/120V circuit from a panel-level installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNEMA Magnetic Shielding Steel Enclosure\u003c\/strong\u003e — Meets code for service entrance, sub-panel, and ceiling plenum installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Series Mode Surge Elimination\u003c\/strong\u003e — Eliminates surge energy without ground contamination or common-mode disturbances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-Mode Impedance Tolerant EMI\/RFI Filter\u003c\/strong\u003e — Reduces electrical noise on the circuit for cleaner AV signal performance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHuddle room\u003c\/li\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-20NE-RT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Configuration\u003c\/td\u003e\n\u003ctd\u003e(1) 20A \/ 120V circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Spec\u003c\/td\u003e\n\u003ctd\u003e(1) 20 Amp circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA magnetic shielding steel; rated for service entrance, sub-panel, and ceiling plenum installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eAdvanced Series Mode with all-mode impedance tolerant EMI\/RFI filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegion\u003c\/td\u003e\n\u003ctd\u003eFor use in the U.S. and Canada only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eIs the SX-20NE-RT compatible with a standard electrical service panel?\u003c\/strong\u003e\u003cbr\u003eYes, it's built in a NEMA magnetic shielding steel enclosure rated for installation at the service entrance, sub-panel, or load center.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWho typically installs the SX-20NE-RT?\u003c\/strong\u003e\u003cbr\u003eBecause it's a panel-level device, it's usually installed by the electrical contractor during rough-in, coordinated with the AV integrator's project scope.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow does this differ from the PF-420?\u003c\/strong\u003e\u003cbr\u003eThe SX-20NE-RT protects a single 20A\/120V circuit, while the PF-420 covers four circuits on an 80-amp load center — the SX-20NE-RT is the right fit when only one dedicated circuit needs branch-level protection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be installed in a ceiling plenum?\u003c\/strong\u003e\u003cbr\u003eYes, the enclosure is rated for ceiling plenum installation in addition to service entrance and sub-panel locations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide during installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can coordinate with your electrical contractor on panel-level surge protection specification as part of a project scope of work.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official Branch Circuit product page (ametekesp.com\/surgex).\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339700809964,"sku":"SX-20NE-RT","price":1059.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/sx20nert.jpg?v=1789010712"},{"product_id":"surgex-sx-ds-151-defender-series-power-conditioner-120v","title":"SurgeX SX-DS-151 Defender Series Power Conditioner, 120V","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-DS-151 is an entry-level, single-outlet surge protector in the Defender Series, built with SurgeX's non-sacrificial Multi-Stage surge suppression technology. It's a cost-effective power conditioner for protecting a single non-critical AV component — a small display, a network switch, or a single piece of peripheral gear — rather than a full rack or room.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe Defender Series is positioned as SurgeX's affordable line for non-critical applications, using patented non-sacrificial Multi-Stage surge suppression rather than the sacrificial MOV-based components found in consumer-grade surge strips. The SX-DS-151 carries a 15A\/120V plug and a single protected outlet, making it the right fit for protecting one piece of equipment rather than an entire rack. Three stages of surge protection guard against electrical transients that can cause AV equipment to disrupt or reboot, and advanced filtering virtually eliminates normal- and common-mode electrical noise that otherwise shows up as reboots or intermittent downtime on connected gear. Because the technology is non-sacrificial, the unit doesn't degrade or need replacement after absorbing a surge event the way MOV-based protectors do, which matters for AV service teams who don't want to inspect single-outlet protectors on a maintenance schedule. For AV system integration work protecting individual components in non-critical spaces — signage players, small switches, single monitors — the SX-DS-151 gives commercial-grade surge protection without the cost of a full power management system.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Sacrificial Multi-Stage Surge Suppression\u003c\/strong\u003e — Patented technology that protects without degrading after a surge event.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Stages of Protection\u003c\/strong\u003e — Guards connected equipment from electrical transients that can cause disruption or reboots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Noise Filtering\u003c\/strong\u003e — Reduces normal- and common-mode electrical noise linked to reboots and downtime.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLowest Amount of Let-Through Energy\u003c\/strong\u003e — Minimizes the surge energy that reaches connected equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-DS-151\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Configuration\u003c\/td\u003e\n\u003ctd\u003e15A \/ 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Configuration\u003c\/td\u003e\n\u003ctd\u003e1 Outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eNon-sacrificial Multi-Stage surge suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiltering\u003c\/td\u003e\n\u003ctd\u003eAdvanced EMI\/RFI noise filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eIs the SX-DS-151 compatible with standard 120V AV equipment?\u003c\/strong\u003e\u003cbr\u003eYes, it's rated for 15A\/120V and provides a single protected outlet for one piece of equipment.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the SX-DS-151 installed?\u003c\/strong\u003e\u003cbr\u003eIt plugs directly between the wall outlet and the protected device — no rack mounting or network connection is required.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it need to be replaced after a surge event?\u003c\/strong\u003e\u003cbr\u003eNo. Its non-sacrificial Multi-Stage technology doesn't degrade after absorbing a surge, unlike MOV-based consumer surge strips.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs this suitable for mission-critical equipment?\u003c\/strong\u003e\u003cbr\u003eSurgeX positions the Defender Series for non-critical applications; for mission-critical racks, the Axess+ or Axess ELITE+ lines add IP control and monitoring.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can advise on the right SurgeX product for a given component and provide ongoing support as part of a service agreement.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official Defender Series product page (ametekesp.com\/surgex).\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339700973804,"sku":"SX-DS-151","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/sxds151.jpg?v=1789010722"},{"product_id":"surgex-sx-dsp-129-defender-series-power-management-system-120v","title":"SurgeX SX-DSP-129 Defender Series+ Power Management System, 120V","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-DSP-129 is a Defender Series+ power management system built on patented Multi-Stage surge suppression, adding SurgeX CONNECT cloud integration on top of the Defender Series' non-sacrificial surge protection. It's a cost-effective power conditioner for AV racks that want cloud-based monitoring without stepping up to a full IP-controlled PDU platform.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe Defender Series+ line extends SurgeX's affordable non-sacrificial surge protection with real-time power monitoring and analytics through SurgeX CONNECT, a cloud-based platform. The SX-DSP-129 carries a 12A\/5-15P plug feeding 9 NEMA outlets, 8 of them switchable plus a front service outlet, giving a rack enough switched capacity for a handful of AV devices at a lower price point than the full Axess+ line. Patented Multi-Stage surge suppression protects connected equipment from harmful surges, and virtually eliminates the electrical noise that causes reboots and downtime on sensitive AV gear. Integration with SurgeX CONNECT means a technician can pull up real-time power monitoring and analytics from a browser rather than physically checking the rack, which is useful for facilities managing several rooms from a central office. Seamless integration with third-party control systems lets the unit report into an existing control processor rather than operating as an island. SurgeX positions the Defender Series+ as an ideal, cost-effective solution for safeguarding non-critical applications — a fit for conference rooms and training spaces where full IP-controlled outlet switching isn't required but cloud visibility into power conditions is still useful.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePatented Multi-Stage Surge Suppression\u003c\/strong\u003e — Non-sacrificial protection against harmful surges without component degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurgeX CONNECT Integration\u003c\/strong\u003e — Real-time power monitoring and analytics through a cloud-based platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThird-Party Control Integration\u003c\/strong\u003e — Reports into existing control systems rather than operating as a standalone device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9 NEMA Outlets, 8 Switchable\u003c\/strong\u003e — Includes a dedicated front service outlet alongside 8 switchable outlets.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-DSP-129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Configuration\u003c\/td\u003e\n\u003ctd\u003e12A \/ 5-15P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Configuration\u003c\/td\u003e\n\u003ctd\u003e9 Outlets \/ 5-15R (8 switchable, 1 front service outlet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003ePatented non-sacrificial Multi-Stage surge suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCloud Integration\u003c\/td\u003e\n\u003ctd\u003eSurgeX CONNECT; third-party control system integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat control systems does the SX-DSP-129 work with?\u003c\/strong\u003e\u003cbr\u003eIt integrates with SurgeX CONNECT for cloud-based monitoring and with third-party control systems for local integration.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the SX-DSP-129 installed?\u003c\/strong\u003e\u003cbr\u003eIt mounts in a standard rack and connects to the network for SurgeX CONNECT access; basic surge protection functions without a network connection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs IP-controlled outlet switching included?\u003c\/strong\u003e\u003cbr\u003eThe Defender Series+ focuses on surge protection and cloud monitoring rather than individually switched IP-controlled outlets; for outlet-level remote switching, see the Axess+ line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it need to be replaced after a surge event?\u003c\/strong\u003e\u003cbr\u003eNo. Its non-sacrificial Multi-Stage technology doesn't degrade after absorbing a surge.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can assist with SurgeX CONNECT setup, control system integration, and ongoing support as part of a project scope of work.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official Defender Series+ product page (ametekesp.com\/surgex).\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339701104876,"sku":"SX-DSP-129","price":1199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/sxdsp129.jpg?v=1789010729"},{"product_id":"surgex-sx-dsp-169-defender-series-power-management-system-120v","title":"SurgeX SX-DSP-169 Defender Series+ Power Management System, 120V","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-DSP-169 is a Defender Series+ power management system built on patented Multi-Stage surge suppression, adding SurgeX CONNECT cloud integration on top of the Defender Series' non-sacrificial surge protection. It's a cost-effective power conditioner for higher-current AV racks that want cloud-based monitoring without stepping up to a full IP-controlled PDU platform.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe Defender Series+ line extends SurgeX's affordable non-sacrificial surge protection with real-time power monitoring and analytics through SurgeX CONNECT, a cloud-based platform. The SX-DSP-169 steps up to a 16A\/5-20P plug feeding 9 NEMA 5-20R outlets, suited to racks running 20A-rated AV or IT equipment at a lower price point than the full Axess+ line. Patented Multi-Stage surge suppression protects connected equipment from harmful surges, and virtually eliminates the electrical noise that causes reboots and downtime on sensitive AV gear. Integration with SurgeX CONNECT means a technician can pull up real-time power monitoring and analytics from a browser rather than physically checking the rack, which is useful for facilities managing several rooms from a central office. Seamless integration with third-party control systems lets the unit report into an existing control processor rather than operating as an island. SurgeX positions the Defender Series+ as an ideal, cost-effective solution for safeguarding non-critical applications — a fit for conference rooms and training spaces running 20A equipment where full IP-controlled outlet switching isn't required but cloud visibility into power conditions is still useful.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePatented Multi-Stage Surge Suppression\u003c\/strong\u003e — Non-sacrificial protection against harmful surges without component degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurgeX CONNECT Integration\u003c\/strong\u003e — Real-time power monitoring and analytics through a cloud-based platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThird-Party Control Integration\u003c\/strong\u003e — Reports into existing control systems rather than operating as a standalone device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9 NEMA 5-20R Outlets\u003c\/strong\u003e — Sized for racks running 20A-rated AV or IT equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-DSP-169\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Configuration\u003c\/td\u003e\n\u003ctd\u003e16A \/ 5-20P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Configuration\u003c\/td\u003e\n\u003ctd\u003e9 Outlets \/ 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003ePatented non-sacrificial Multi-Stage surge suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCloud Integration\u003c\/td\u003e\n\u003ctd\u003eSurgeX CONNECT; third-party control system integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat control systems does the SX-DSP-169 work with?\u003c\/strong\u003e\u003cbr\u003eIt integrates with SurgeX CONNECT for cloud-based monitoring and with third-party control systems for local integration.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the SX-DSP-169 installed?\u003c\/strong\u003e\u003cbr\u003eIt mounts in a standard rack and connects to the network for SurgeX CONNECT access; basic surge protection functions without a network connection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs IP-controlled outlet switching included?\u003c\/strong\u003e\u003cbr\u003eThe Defender Series+ focuses on surge protection and cloud monitoring rather than individually switched IP-controlled outlets; for outlet-level remote switching, see the Axess+ line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it need to be replaced after a surge event?\u003c\/strong\u003e\u003cbr\u003eNo. Its non-sacrificial Multi-Stage technology doesn't degrade after absorbing a surge.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can assist with SurgeX CONNECT setup, control system integration, and ongoing support as part of a project scope of work.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official Defender Series+ product page (ametekesp.com\/surgex).\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339701334252,"sku":"SX-DSP-169","price":1249.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/sxdsp169.jpg?v=1789010737"},{"product_id":"surgex-ev-12015-ic-envision-ic-power-conditioner-120v-15a","title":"SurgeX EV-12015 IC enVision IC Power Conditioner, 120V\/15A","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX EV-12015 IC is a power conditioner in the enVision line that pairs surge protection with predictive analytics software, giving AV service teams visibility into power conditions at a customer site rather than a simple pass\/fail surge indicator. It's built for AV integrators who manage service contracts across multiple sites and want data to support root-cause discussions rather than guesswork after a service call.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eMost power conditioners stop at surge protection; the enVision IC line adds a data layer on top, gathering and analyzing power conditions at the install site to help identify the root cause of equipment issues. The EV-12015 IC carries a 15A\/120V plug feeding three 5-15R outlets, sized for a single rack or a small cluster of AV components on a standard 120V circuit. Innovative algorithms and predictive analytics software interpret the collected data into key metrics and trends, baselining the electrical factors that influence equipment operation, damage conditions, and inefficiencies over time. Rather than waiting for a device to fail, the enVision software works to discover anomalies and patterns that can lead to connected equipment failure in advance, which lets a service technician remedy an emerging issue proactively instead of reacting to a support call. For AV service organizations managing recurring maintenance contracts, that analytics layer turns a routine power conditioner into a data source for informed, faster business decisions about which sites need attention first.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePredictive Analytics Software\u003c\/strong\u003e — Discovers anomalies and patterns that can lead to equipment failure before it happens.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Condition Visibility\u003c\/strong\u003e — Gathers and analyzes site-level power data to support root-cause discussions with affected customers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey Metrics and Trend Baselining\u003c\/strong\u003e — Interprets data into metrics that track equipment operation, damage conditions, and inefficiencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProactive Issue Remediation\u003c\/strong\u003e — Flags emerging problems so technicians can act before downtime occurs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEV-12015 IC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Configuration\u003c\/td\u003e\n\u003ctd\u003e15A \/ 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Configuration\u003c\/td\u003e\n\u003ctd\u003e3 Outlets \/ 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003ctd\u003eenVision predictive analytics and reporting platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat does the enVision analytics software require to operate?\u003c\/strong\u003e\u003cbr\u003eIt requires a network connection so the unit can report power condition data to the enVision analytics platform for trend analysis and anomaly detection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the EV-12015 IC installed?\u003c\/strong\u003e\u003cbr\u003eIt installs like a standard rack-mount power conditioner, plugging into a 15A\/120V circuit, with an added network connection for analytics reporting.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it integrate with an existing service ticketing system?\u003c\/strong\u003e\u003cbr\u003eThe enVision platform is designed to support root-cause discussions and proactive service; specific ticketing system integrations should be confirmed with SurgeX for a given deployment.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs this compatible with other SurgeX enVision models?\u003c\/strong\u003e\u003cbr\u003eYes, EV-12015 IC, EV-12020 IC, EV-20815 IC, and EV-20820 IC share the same enVision analytics platform across different amperage and voltage configurations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can assist with enVision analytics setup and ongoing service coordination as part of a maintenance agreement.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official enVision IC product page (ametekesp.com\/surgex). Part number shown as listed on the manufacturer site (\"EV-12015 IC\") — confirm exact formatting before publishing.\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339701563628,"sku":"EV-12015 IC","price":749.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/ev12015ic.jpg?v=1789010752"},{"product_id":"surgex-ev-12020-ic-envision-ic-power-conditioner-120v-20a","title":"SurgeX EV-12020 IC enVision IC Power Conditioner, 120V\/20A","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX EV-12020 IC is a power conditioner in the enVision line that pairs surge protection with predictive analytics software, giving AV service teams visibility into power conditions at a customer site rather than a simple pass\/fail surge indicator. It's built for AV integrators who manage service contracts across multiple sites and want data to support root-cause discussions rather than guesswork after a service call.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eMost power conditioners stop at surge protection; the enVision IC line adds a data layer on top, gathering and analyzing power conditions at the install site to help identify the root cause of equipment issues. The EV-12020 IC carries a 20A\/120V plug feeding a mixed outlet bank — one 5-20R and two 5-15R outlets — sized for a rack mixing 20A-rated equipment with standard AV gear. Innovative algorithms and predictive analytics software interpret the collected data into key metrics and trends, baselining the electrical factors that influence equipment operation, damage conditions, and inefficiencies over time. Rather than waiting for a device to fail, the enVision software works to discover anomalies and patterns that can lead to connected equipment failure in advance, which lets a service technician remedy an emerging issue proactively instead of reacting to a support call. For AV service organizations managing recurring maintenance contracts on mixed-amperage racks, that analytics layer turns a routine power conditioner into a data source for informed, faster business decisions about which sites need attention first.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePredictive Analytics Software\u003c\/strong\u003e — Discovers anomalies and patterns that can lead to equipment failure before it happens.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Condition Visibility\u003c\/strong\u003e — Gathers and analyzes site-level power data to support root-cause discussions with affected customers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey Metrics and Trend Baselining\u003c\/strong\u003e — Interprets data into metrics that track equipment operation, damage conditions, and inefficiencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProactive Issue Remediation\u003c\/strong\u003e — Flags emerging problems so technicians can act before downtime occurs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEV-12020 IC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Configuration\u003c\/td\u003e\n\u003ctd\u003e20A \/ 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Configuration\u003c\/td\u003e\n\u003ctd\u003e1 Outlet \/ 5-20R + 2 Outlets \/ 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003ctd\u003eenVision predictive analytics and reporting platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat does the enVision analytics software require to operate?\u003c\/strong\u003e\u003cbr\u003eIt requires a network connection so the unit can report power condition data to the enVision analytics platform for trend analysis and anomaly detection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the EV-12020 IC installed?\u003c\/strong\u003e\u003cbr\u003eIt installs like a standard rack-mount power conditioner, plugging into a 20A\/120V circuit, with an added network connection for analytics reporting.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it support mixed 15A and 20A equipment?\u003c\/strong\u003e\u003cbr\u003eYes, the 5-15R and 5-20R outlet mix lets a single rack run both standard AV gear and 20A-rated equipment from one unit.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs this compatible with other SurgeX enVision models?\u003c\/strong\u003e\u003cbr\u003eYes, EV-12015 IC, EV-12020 IC, EV-20815 IC, and EV-20820 IC share the same enVision analytics platform across different amperage and voltage configurations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can assist with enVision analytics setup and ongoing service coordination as part of a maintenance agreement.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official enVision IC product page (ametekesp.com\/surgex). Part number shown as listed on the manufacturer site (\"EV-12020 IC\") — confirm exact formatting before publishing.\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339701694700,"sku":"EV-12020 IC","price":829.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/ev12020ic.jpg?v=1789010762"},{"product_id":"surgex-ev-20815-ic-envision-ic-power-conditioner-208v-15a","title":"SurgeX EV-20815 IC enVision IC Power Conditioner, 208V\/15A","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX EV-20815 IC is a 208-240V power conditioner in the enVision line that pairs surge protection with predictive analytics software, giving AV service teams visibility into power conditions at a customer site rather than a simple pass\/fail surge indicator. It's built for AV integrators who manage service contracts across multiple sites and want data to support root-cause discussions rather than guesswork after a service call.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eMost power conditioners stop at surge protection; the enVision IC line adds a data layer on top, gathering and analyzing power conditions at the install site to help identify the root cause of equipment issues. The EV-20815 IC carries a 15A\/208-240V plug feeding a single 6-15R outlet, sized for higher-voltage AV or broadcast equipment run on a 208-240V circuit rather than standard 120V. Innovative algorithms and predictive analytics software interpret the collected data into key metrics and trends, baselining the electrical factors that influence equipment operation, damage conditions, and inefficiencies over time. Rather than waiting for a device to fail, the enVision software works to discover anomalies and patterns that can lead to connected equipment failure in advance, which lets a service technician remedy an emerging issue proactively instead of reacting to a support call. For AV service organizations managing recurring maintenance contracts on 208-240V equipment, that analytics layer turns a routine power conditioner into a data source for informed, faster business decisions about which sites need attention first.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePredictive Analytics Software\u003c\/strong\u003e — Discovers anomalies and patterns that can lead to equipment failure before it happens.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Condition Visibility\u003c\/strong\u003e — Gathers and analyzes site-level power data to support root-cause discussions with affected customers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey Metrics and Trend Baselining\u003c\/strong\u003e — Interprets data into metrics that track equipment operation, damage conditions, and inefficiencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProactive Issue Remediation\u003c\/strong\u003e — Flags emerging problems so technicians can act before downtime occurs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEV-20815 IC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Configuration\u003c\/td\u003e\n\u003ctd\u003e15A \/ 208-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Configuration\u003c\/td\u003e\n\u003ctd\u003e1 Outlet \/ 6-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003ctd\u003eenVision predictive analytics and reporting platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat does the enVision analytics software require to operate?\u003c\/strong\u003e\u003cbr\u003eIt requires a network connection so the unit can report power condition data to the enVision analytics platform for trend analysis and anomaly detection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the EV-20815 IC installed?\u003c\/strong\u003e\u003cbr\u003eIt installs like a standard rack-mount power conditioner, plugging into a 15A\/208-240V circuit, with an added network connection for analytics reporting.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy choose a 208-240V model instead of the 120V line?\u003c\/strong\u003e\u003cbr\u003eFacilities running higher-voltage AV, broadcast, or IT equipment need the 208-240V input; the 120V enVision IC models cover standard AV circuits.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs this compatible with other SurgeX enVision models?\u003c\/strong\u003e\u003cbr\u003eYes, EV-12015 IC, EV-12020 IC, EV-20815 IC, and EV-20820 IC share the same enVision analytics platform across different amperage and voltage configurations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can assist with enVision analytics setup and ongoing service coordination as part of a maintenance agreement.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official enVision IC product page (ametekesp.com\/surgex). Part number shown as listed on the manufacturer site (\"EV-20815 IC\") — confirm exact formatting before publishing.\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339701891308,"sku":"EV-20815 IC","price":749.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/ev20815ic.jpg?v=1789010766"},{"product_id":"surgex-ev-20820-ic-envision-ic-power-conditioner-208v-20a","title":"SurgeX EV-20820 IC enVision IC Power Conditioner, 208V\/20A","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX EV-20820 IC is a 208-240V power conditioner in the enVision line that pairs surge protection with predictive analytics software, giving AV service teams visibility into power conditions at a customer site rather than a simple pass\/fail surge indicator. It's built for AV integrators who manage service contracts across multiple sites and want data to support root-cause discussions rather than guesswork after a service call.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eMost power conditioners stop at surge protection; the enVision IC line adds a data layer on top, gathering and analyzing power conditions at the install site to help identify the root cause of equipment issues. The EV-20820 IC carries a 20A\/208-240V plug feeding a single 6-20R outlet, sized for higher-voltage, higher-current AV or broadcast equipment run on a 208-240V circuit rather than standard 120V. Innovative algorithms and predictive analytics software interpret the collected data into key metrics and trends, baselining the electrical factors that influence equipment operation, damage conditions, and inefficiencies over time. Rather than waiting for a device to fail, the enVision software works to discover anomalies and patterns that can lead to connected equipment failure in advance, which lets a service technician remedy an emerging issue proactively instead of reacting to a support call. For AV service organizations managing recurring maintenance contracts on 208-240V equipment, that analytics layer turns a routine power conditioner into a data source for informed, faster business decisions about which sites need attention first.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePredictive Analytics Software\u003c\/strong\u003e — Discovers anomalies and patterns that can lead to equipment failure before it happens.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Condition Visibility\u003c\/strong\u003e — Gathers and analyzes site-level power data to support root-cause discussions with affected customers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey Metrics and Trend Baselining\u003c\/strong\u003e — Interprets data into metrics that track equipment operation, damage conditions, and inefficiencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProactive Issue Remediation\u003c\/strong\u003e — Flags emerging problems so technicians can act before downtime occurs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEV-20820 IC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Configuration\u003c\/td\u003e\n\u003ctd\u003e20A \/ 208-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Configuration\u003c\/td\u003e\n\u003ctd\u003e1 Outlet \/ 6-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003ctd\u003eenVision predictive analytics and reporting platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat does the enVision analytics software require to operate?\u003c\/strong\u003e\u003cbr\u003eIt requires a network connection so the unit can report power condition data to the enVision analytics platform for trend analysis and anomaly detection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the EV-20820 IC installed?\u003c\/strong\u003e\u003cbr\u003eIt installs like a standard rack-mount power conditioner, plugging into a 20A\/208-240V circuit, with an added network connection for analytics reporting.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy choose a 208-240V model instead of the 120V line?\u003c\/strong\u003e\u003cbr\u003eFacilities running higher-voltage, higher-current AV, broadcast, or IT equipment need the 208-240V input; the 120V enVision IC models cover standard AV circuits.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs this compatible with other SurgeX enVision models?\u003c\/strong\u003e\u003cbr\u003eYes, EV-12015 IC, EV-12020 IC, EV-20815 IC, and EV-20820 IC share the same enVision analytics platform across different amperage and voltage configurations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can assist with enVision analytics setup and ongoing service coordination as part of a maintenance agreement.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official enVision IC product page (ametekesp.com\/surgex). Part number shown as listed on the manufacturer site (\"EV-20820 IC\") — confirm exact formatting before publishing.\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339702120684,"sku":"EV-20820 IC","price":859.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/ev20820ic.jpg?v=1789010769"},{"product_id":"surgex-xr315-home-theater-surge-eliminator-120v","title":"SurgeX XR-315 – Rack Mount Surge Eliminator \u0026 Power Conditioner w\/Remote, 1RU, 120V\/15A","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX XR315 is a Home Theater series surge eliminator built around Advanced Series Mode surge protection with a self-test circuit and visual status indicator. It's positioned for residential and light-commercial home theater and small AV installs where a technician needs a quick visual confirmation that surge protection is active without pulling a meter.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe Home Theater line applies SurgeX's Advanced Series Mode surge elimination technology, the same non-sacrificial approach used across the commercial SurgeX product lines, in a form factor aimed at home theater and residential AV installs. The XR315 includes a self-test circuit with a visual indicator, so an integrator or homeowner can confirm the unit is actively protecting connected equipment at a glance rather than waiting for a failure to find out. A 9-foot grounded 3-wire cord gives installation flexibility behind a rack or media cabinet without needing an extension cord, which matters in tight AV closets. In-rush current elimination (ICE) protects against the power draw spike when several devices power on at once, and the impedance-tolerant EMI\/RFI filter reduces electrical noise that can show up as audio hum or video artifacts on sensitive home theater equipment. For AV integrators handling both commercial racks and residential home theater installs, the XR315 extends SurgeX's Advanced Series Mode protection to smaller-scale projects.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Series Mode Surge Elimination\u003c\/strong\u003e — Non-sacrificial surge protection for connected home theater and AV equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Test Circuit with Visual Indicator\u003c\/strong\u003e — Confirms active protection status at a glance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9' Grounded 3-Wire Cord\u003c\/strong\u003e — Provides installation flexibility behind racks or media cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIn-Rush Current Elimination (ICE)\u003c\/strong\u003e — Prevents power-up current spikes from tripping breakers when multiple devices start simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpedance-Tolerant EMI\/RFI Filter\u003c\/strong\u003e — Reduces electrical noise that can affect audio and video signal quality.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eXR315\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eAdvanced Series Mode with In-Rush Current Elimination (ICE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiltering\u003c\/td\u003e\n\u003ctd\u003eImpedance-tolerant EMI\/RFI filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord\u003c\/td\u003e\n\u003ctd\u003e9' grounded 3-wire cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eSelf-test circuit with visual indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eHow is the XR315 installed?\u003c\/strong\u003e\u003cbr\u003eIt plugs directly between the wall outlet and connected home theater or AV equipment; the 9' cord allows placement behind a rack or media cabinet.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do I know the XR315 is actively protecting my equipment?\u003c\/strong\u003e\u003cbr\u003eThe self-test circuit includes a visual indicator that confirms protection status without needing a meter.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs this suitable for a light-commercial AV install, or only residential?\u003c\/strong\u003e\u003cbr\u003eBoth. It uses the same Advanced Series Mode technology as SurgeX's commercial lines, scaled for smaller home theater and light-commercial installs.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it need to be replaced after a surge event?\u003c\/strong\u003e\u003cbr\u003eNo. Advanced Series Mode is a non-sacrificial technology that doesn't degrade after absorbing a surge.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can advise on the right SurgeX product for a given home theater or small AV install.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official Home Theater product page (ametekesp.com\/surgex); plug and outlet configuration not published on the manufacturer page and left out rather than guessed.\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339702284524,"sku":"XR-315","price":1529.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/xr315.jpg?v=1789010776"},{"product_id":"surgex-sa-15-standalone-surge-eliminator-120v-15a","title":"SurgeX SA-15 Standalone Surge Eliminator, 120V\/15A","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SA-15 is a standalone surge protector built on Advanced Series Mode technology and Impedance Tolerant EMI\/RFI filtration, delivering patented surge elimination and power conditioning for equipment that relies on peak AV performance. It's a compact option for protecting one or two pieces of AV equipment where a full rack power management system isn't required.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe Standalone series uses non-sacrificial components that don't degrade or fail after absorbing a surge event, unlike MOV-based consumer protectors that wear out over repeated surges. The SA-15 carries a 15A\/120V plug feeding 2 protected outlets, sized for protecting a display, amplifier, or signal processor pair rather than a full rack. It eliminates surge energy up to 6,000 volts without producing the harmful ground contamination or common-mode disturbances that can cause hissing sounds and pixelation on connected AV systems — a common symptom when a surge protector introduces its own noise onto the signal chain. That noise-free protection is the main reason SurgeX Standalone units get specified ahead of a display or DSP rather than a generic surge strip in rooms where audio and video quality matter. For AV system integration on individual components in conference rooms, classrooms, or single-display installs, the SA-15 gives commercial-grade surge protection without the footprint of a rack-mount unit.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Series Mode Technology\u003c\/strong\u003e — Patented, non-sacrificial surge elimination that doesn't degrade over time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpedance Tolerant EMI\/RFI Filtration\u003c\/strong\u003e — Removes electrical noise that can cause hissing or pixelation on AV systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEliminates Surge Energy Up to 6,000 Volts\u003c\/strong\u003e — Protects connected equipment without ground contamination or common-mode disturbances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Sacrificial Components\u003c\/strong\u003e — Never degrade or fail, keeping equipment protected over the life of the unit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eHuddle room\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSA-15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Configuration\u003c\/td\u003e\n\u003ctd\u003e15A \/ 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Configuration\u003c\/td\u003e\n\u003ctd\u003e2 Outlets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eAdvanced Series Mode; eliminates surge energy up to 6,000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiltering\u003c\/td\u003e\n\u003ctd\u003eImpedance Tolerant EMI\/RFI filtration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eHow is the SA-15 installed?\u003c\/strong\u003e\u003cbr\u003eIt plugs directly between the wall outlet and connected AV equipment — no rack mounting or network connection is required.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWill the SA-15 introduce any noise into my audio or video signal?\u003c\/strong\u003e\u003cbr\u003eNo. Its Impedance Tolerant EMI\/RFI filtration is designed specifically to avoid the ground contamination and common-mode noise that can cause hissing or pixelation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it need to be replaced after a surge event?\u003c\/strong\u003e\u003cbr\u003eNo. Advanced Series Mode is a non-sacrificial technology that doesn't degrade after absorbing a surge.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this protect a rack of equipment, or just one or two devices?\u003c\/strong\u003e\u003cbr\u003eThe SA-15 is sized for one or two devices; for full-rack protection with more outlets, see the Axess+ or Defender Series+ lines.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can advise on the right SurgeX product for a given component and provide ongoing support as part of a service agreement.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official Standalone product page (ametekesp.com\/surgex).\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339702481132,"sku":"SA-15","price":749.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/sa15.jpg?v=1789010783"},{"product_id":"surgex-sa-20-standalone-surge-eliminator-120v-20a","title":"SurgeX SA-20 Standalone Surge Eliminator, 120V\/20A","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SA-20 is a standalone surge protector built on Advanced Series Mode technology and Impedance Tolerant EMI\/RFI filtration, delivering patented surge elimination and power conditioning for equipment that relies on peak AV performance. It's a compact option for protecting one or two pieces of 20A-rated AV equipment where a full rack power management system isn't required.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe Standalone series uses non-sacrificial components that don't degrade or fail after absorbing a surge event, unlike MOV-based consumer protectors that wear out over repeated surges. The SA-20 carries a 20A\/120V plug feeding 2 protected outlets, sized for protecting higher-draw AV equipment such as a power amplifier or a display with an integrated media player. It eliminates surge energy up to 6,000 volts without producing the harmful ground contamination or common-mode disturbances that can cause hissing sounds and pixelation on connected AV systems — a common symptom when a surge protector introduces its own noise onto the signal chain. That noise-free protection is the main reason SurgeX Standalone units get specified ahead of a display or DSP rather than a generic surge strip in rooms where audio and video quality matter. For AV system integration on individual 20A components in conference rooms, classrooms, or single-display installs, the SA-20 gives commercial-grade surge protection without the footprint of a rack-mount unit.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Series Mode Technology\u003c\/strong\u003e — Patented, non-sacrificial surge elimination that doesn't degrade over time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpedance Tolerant EMI\/RFI Filtration\u003c\/strong\u003e — Removes electrical noise that can cause hissing or pixelation on AV systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEliminates Surge Energy Up to 6,000 Volts\u003c\/strong\u003e — Protects connected equipment without ground contamination or common-mode disturbances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Sacrificial Components\u003c\/strong\u003e — Never degrade or fail, keeping equipment protected over the life of the unit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eHuddle room\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSA-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Configuration\u003c\/td\u003e\n\u003ctd\u003e20A \/ 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Configuration\u003c\/td\u003e\n\u003ctd\u003e2 Outlets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eAdvanced Series Mode; eliminates surge energy up to 6,000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiltering\u003c\/td\u003e\n\u003ctd\u003eImpedance Tolerant EMI\/RFI filtration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eHow is the SA-20 installed?\u003c\/strong\u003e\u003cbr\u003eIt plugs directly between the wall outlet and connected AV equipment — no rack mounting or network connection is required.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWill the SA-20 introduce any noise into my audio or video signal?\u003c\/strong\u003e\u003cbr\u003eNo. Its Impedance Tolerant EMI\/RFI filtration is designed specifically to avoid the ground contamination and common-mode noise that can cause hissing or pixelation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it need to be replaced after a surge event?\u003c\/strong\u003e\u003cbr\u003eNo. Advanced Series Mode is a non-sacrificial technology that doesn't degrade after absorbing a surge.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this protect a rack of equipment, or just one or two devices?\u003c\/strong\u003e\u003cbr\u003eThe SA-20 is sized for one or two 20A-rated devices; for full-rack protection with more outlets, see the Axess+ or Defender Series+ lines.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can advise on the right SurgeX product for a given component and provide ongoing support as part of a service agreement.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official Standalone product page (ametekesp.com\/surgex).\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339702644972,"sku":"SA-20","price":769.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/surgex-sa-20-surge-eliminator-front-three-quarter.jpg?v=1789078364"},{"product_id":"surgex-ups-33020-02-three-phase-ups-large-format","title":"SurgeX UPS-33020-02 Three-Phase UPS, Large Format","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX UPS-33020-02 is a large-format, three-phase uninterruptible power supply built for mission-critical AV and IT installations that need conditioned, regenerated power rather than a standard battery backup. It's sized for control rooms, broadcast facilities, and data closets running three-phase equipment where downtime isn't an option.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eSurgeX's Large Format three-phase UPS line is built around a 1.0 power factor design with high efficiency rated up to 94%, and an ECO mode that reaches 97% efficiency for installations that can tolerate a brief transfer to bypass power during normal operation. The UPS-33020-02 delivers online double-conversion protection, keeping connected three-phase equipment on regenerated power rather than switching sources during a utility disturbance. Convenient top and side access simplifies serviceability in tight equipment rooms, reducing the time a technician spends accessing internal components during maintenance. An optional SNMP network card and Modbus support let facilities integrate the UPS into existing building management or network monitoring systems rather than checking status locally. For AV and IT integrators specifying three-phase backup power for control rooms and data closets, that combination of high efficiency and simplified serviceability is the main draw over a standard single-phase UPS scaled up with external transfer switches.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1.0 Power Factor\u003c\/strong\u003e — Delivers full rated capacity to connected equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Efficiency Rate, Up to 94%\u003c\/strong\u003e — Reduces operating cost and heat load compared to lower-efficiency UPS designs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECO Mode, 97% Efficient\u003c\/strong\u003e — Higher-efficiency operating mode for installations that can tolerate brief bypass transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvenient Top and Side Access\u003c\/strong\u003e — Simplifies serviceability in equipment rooms with limited clearance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional SNMP Network Card and Modbus\u003c\/strong\u003e — Integrates with building management and network monitoring systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUPS-33020-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 94% (97% in ECO mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Options\u003c\/td\u003e\n\u003ctd\u003eOptional SNMP network card (models 3000S-01, 3000S-02, 3000S-03) and Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDoes the UPS-33020-02 integrate with a building management or network monitoring system?\u003c\/strong\u003e\u003cbr\u003eYes, via an optional SNMP network card (models 3000S-01, 3000S-02, 3000S-03) and Modbus support.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the UPS-33020-02 serviced?\u003c\/strong\u003e\u003cbr\u003eConvenient top and side access simplifies maintenance in tight equipment rooms without requiring rear clearance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes ECO mode affect power protection?\u003c\/strong\u003e\u003cbr\u003eECO mode raises efficiency to 97% but introduces a brief bypass transfer; standard online double-conversion mode keeps equipment on continuously regenerated power.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs this compatible with three-phase electrical service only?\u003c\/strong\u003e\u003cbr\u003eYes, this model is built for three-phase installations; for single-phase large-format UPS, see the UPS-42100-85R.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide for installation and commissioning?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can coordinate three-phase UPS installation with your electrical contractor and assist with SNMP\/Modbus integration as part of a project scope of work.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official Large Format Three-Phase UPS product page (ametekesp.com\/surgex); kVA\/capacity rating for this specific model number is on the linked data sheet and not restated here to avoid approximating it.\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339702776044,"sku":"UPS-33020-02","price":43499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/surgex-ups-33020-02-three-phase-ups-front.jpg?v=1789078364"},{"product_id":"surgex-ups-33030-12-three-phase-ups-large-format","title":"SurgeX UPS-33030-12 Three-Phase UPS, Large Format","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX UPS-33030-12 is a large-format, three-phase uninterruptible power supply built for mission-critical AV and IT installations that need conditioned, regenerated power rather than a standard battery backup. It's sized for control rooms, broadcast facilities, and data closets running three-phase equipment where downtime isn't an option.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eSurgeX's Large Format three-phase UPS line is built around a 1.0 power factor design with high efficiency rated up to 94%, and an ECO mode that reaches 97% efficiency for installations that can tolerate a brief transfer to bypass power during normal operation. The UPS-33030-12 delivers online double-conversion protection, keeping connected three-phase equipment on regenerated power rather than switching sources during a utility disturbance. Convenient top and side access simplifies serviceability in tight equipment rooms, reducing the time a technician spends accessing internal components during maintenance. An optional SNMP network card and Modbus support let facilities integrate the UPS into existing building management or network monitoring systems rather than checking status locally. For AV and IT integrators specifying three-phase backup power for control rooms and data closets, that combination of high efficiency and simplified serviceability is the main draw over a standard single-phase UPS scaled up with external transfer switches.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1.0 Power Factor\u003c\/strong\u003e — Delivers full rated capacity to connected equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Efficiency Rate, Up to 94%\u003c\/strong\u003e — Reduces operating cost and heat load compared to lower-efficiency UPS designs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECO Mode, 97% Efficient\u003c\/strong\u003e — Higher-efficiency operating mode for installations that can tolerate brief bypass transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvenient Top and Side Access\u003c\/strong\u003e — Simplifies serviceability in equipment rooms with limited clearance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional SNMP Network Card and Modbus\u003c\/strong\u003e — Integrates with building management and network monitoring systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUPS-33030-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 94% (97% in ECO mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Options\u003c\/td\u003e\n\u003ctd\u003eOptional SNMP network card (models 3000S-01, 3000S-02, 3000S-03) and Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDoes the UPS-33030-12 integrate with a building management or network monitoring system?\u003c\/strong\u003e\u003cbr\u003eYes, via an optional SNMP network card (models 3000S-01, 3000S-02, 3000S-03) and Modbus support.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the UPS-33030-12 serviced?\u003c\/strong\u003e\u003cbr\u003eConvenient top and side access simplifies maintenance in tight equipment rooms without requiring rear clearance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes ECO mode affect power protection?\u003c\/strong\u003e\u003cbr\u003eECO mode raises efficiency to 97% but introduces a brief bypass transfer; standard online double-conversion mode keeps equipment on continuously regenerated power.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs this compatible with three-phase electrical service only?\u003c\/strong\u003e\u003cbr\u003eYes, this model is built for three-phase installations; for single-phase large-format UPS, see the UPS-42100-85R.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide for installation and commissioning?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can coordinate three-phase UPS installation with your electrical contractor and assist with SNMP\/Modbus integration as part of a project scope of work.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official Large Format Three-Phase UPS product page (ametekesp.com\/surgex); kVA\/capacity rating for this specific model number is on the linked data sheet and not restated here to avoid approximating it.\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339702972652,"sku":"UPS-33030-12","price":55599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/surgex-ups-33030-12-three-phase-ups-front.png?v=1789078372"},{"product_id":"surgex-ups-33040-12-three-phase-ups-large-format","title":"SurgeX UPS-33040-12 Three-Phase UPS, Large Format","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX UPS-33040-12 is a large-format, three-phase uninterruptible power supply built for mission-critical AV and IT installations that need conditioned, regenerated power rather than a standard battery backup. It's sized for control rooms, broadcast facilities, and data closets running three-phase equipment where downtime isn't an option.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eSurgeX's Large Format three-phase UPS line is built around a 1.0 power factor design with high efficiency rated up to 94%, and an ECO mode that reaches 97% efficiency for installations that can tolerate a brief transfer to bypass power during normal operation. The UPS-33040-12 delivers online double-conversion protection, keeping connected three-phase equipment on regenerated power rather than switching sources during a utility disturbance. Convenient top and side access simplifies serviceability in tight equipment rooms, reducing the time a technician spends accessing internal components during maintenance. An optional SNMP network card and Modbus support let facilities integrate the UPS into existing building management or network monitoring systems rather than checking status locally. For AV and IT integrators specifying three-phase backup power for control rooms and data closets, that combination of high efficiency and simplified serviceability is the main draw over a standard single-phase UPS scaled up with external transfer switches.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1.0 Power Factor\u003c\/strong\u003e — Delivers full rated capacity to connected equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Efficiency Rate, Up to 94%\u003c\/strong\u003e — Reduces operating cost and heat load compared to lower-efficiency UPS designs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eECO Mode, 97% Efficient\u003c\/strong\u003e — Higher-efficiency operating mode for installations that can tolerate brief bypass transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvenient Top and Side Access\u003c\/strong\u003e — Simplifies serviceability in equipment rooms with limited clearance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional SNMP Network Card and Modbus\u003c\/strong\u003e — Integrates with building management and network monitoring systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUPS-33040-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 94% (97% in ECO mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Options\u003c\/td\u003e\n\u003ctd\u003eOptional SNMP network card (models 3000S-01, 3000S-02, 3000S-03) and Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDoes the UPS-33040-12 integrate with a building management or network monitoring system?\u003c\/strong\u003e\u003cbr\u003eYes, via an optional SNMP network card (models 3000S-01, 3000S-02, 3000S-03) and Modbus support.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the UPS-33040-12 serviced?\u003c\/strong\u003e\u003cbr\u003eConvenient top and side access simplifies maintenance in tight equipment rooms without requiring rear clearance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes ECO mode affect power protection?\u003c\/strong\u003e\u003cbr\u003eECO mode raises efficiency to 97% but introduces a brief bypass transfer; standard online double-conversion mode keeps equipment on continuously regenerated power.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs this compatible with three-phase electrical service only?\u003c\/strong\u003e\u003cbr\u003eYes, this model is built for three-phase installations; for single-phase large-format UPS, see the UPS-42100-85R.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide for installation and commissioning?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can coordinate three-phase UPS installation with your electrical contractor and assist with SNMP\/Modbus integration as part of a project scope of work.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official Large Format Three-Phase UPS product page (ametekesp.com\/surgex); kVA\/capacity rating for this specific model number is on the linked data sheet and not restated here to avoid approximating it.\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339703136492,"sku":"UPS-33040-12","price":58599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/surgex-ups-33040-12-three-phase-ups-front.png?v=1789078372"},{"product_id":"surgex-ups-42100-85r-single-phase-ups-large-format","title":"SurgeX UPS-42100-85R Single-Phase UPS, Large Format","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX UPS-42100-85R is a large-format, single-phase 10kVA uninterruptible power supply built on true online double-conversion technology with an integrated isolation transformer. It's designed for mission-critical AV and IT equipment that can't tolerate a transfer gap during a power event, and for facilities that want conditioned power output when running on generator backup.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eStandard line-interactive UPS units introduce a brief transfer time when switching to battery, which is enough to reboot sensitive equipment during a power event. The UPS-42100-85R regenerates AC power through true online double-conversion, meaning connected equipment always runs on regenerated power with no transfer time rather than switching sources during an outage. A low impedance isolation transformer entirely re-establishes the neutral-to-ground bond, a combination unique to the industry that eradicates harmonics and common-mode noise for optimum performance and reliability. Rated at 10kVA with a 208-240V input and 120-240V, 10000W hardwired output, the unit's output receptacle panel and input line cord can be custom designed for quick, on-site connection to equipment. A static bypass switch maintains power to connected equipment if the UPS itself needs servicing, and an inrush load rating up to 300% handles the power-up surge from multiple devices starting simultaneously. Over\/under voltage shutdown and internal temperature fault shutdown protect the unit itself, while an industry-leading -30%\/+15% input voltage range keeps the unit on-line through utility fluctuations that would force a narrower-range UPS onto battery. Expandable battery packs extend runtime as project requirements grow, and multiple control options including SNMP support remote monitoring from a network operations center. For AV and IT integrators supporting mission-critical racks, that combination of zero-transfer-time double conversion and isolation-transformer noise rejection is what separates the UPS-42100-85R from a standard battery backup.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue Online Double-Conversion\u003c\/strong\u003e — Regenerates AC power with no transfer time during a power event.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Impedance Isolation Transformer\u003c\/strong\u003e — Re-establishes the neutral-to-ground bond and eradicates harmonics and common-mode noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatic Bypass Switch\u003c\/strong\u003e — Maintains power to connected equipment during UPS servicing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Load Rating Up to 300%\u003c\/strong\u003e — Handles simultaneous power-up of multiple connected devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustry-Leading -30%\/+15% Voltage Range\u003c\/strong\u003e — Stays on-line through utility fluctuations that would trip a narrower-range UPS to battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpandable Battery Packs\u003c\/strong\u003e — Extends runtime as project requirements change.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Control Options Including SNMP\u003c\/strong\u003e — Supports remote monitoring and management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmallest Footprint in the Industry\u003c\/strong\u003e — Reduces the equipment room or rack space required for large-format UPS backup.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUPS-42100-85R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e10kVA, single-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Configuration\u003c\/td\u003e\n\u003ctd\u003e208-240V in \/ 120-240V out, 10000W hardwired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Type\u003c\/td\u003e\n\u003ctd\u003eTrue online double-conversion with isolation transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e-30% \/ +15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Options\u003c\/td\u003e\n\u003ctd\u003eMultiple, including optional SNMP (models 3000S-01, 3000S-02, 3000S-03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eDoes the UPS-42100-85R work with an existing building management or network monitoring system?\u003c\/strong\u003e\u003cbr\u003eYes, via optional SNMP network cards (models 3000S-01, 3000S-02, 3000S-03) and Modbus support.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the UPS-42100-85R installed?\u003c\/strong\u003e\u003cbr\u003eThe output receptacle panel and input line cord can be custom designed for quick, on-site connection; it's typically hardwired by an electrical contractor given its 10000W rating.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this UPS run in conjunction with a generator?\u003c\/strong\u003e\u003cbr\u003eYes, it's designed to work with a generator for excess carryover and conditioned power output, or on its own to ensure safe equipment shutdown.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes switching to battery cause a brief power interruption?\u003c\/strong\u003e\u003cbr\u003eNo. True online double-conversion means connected equipment always runs on regenerated power, with no transfer time during a power event.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide for installation and commissioning?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can coordinate with your electrical contractor on hardwired installation and assist with SNMP\/Modbus integration as part of a project scope of work.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official Large Format UPS product page (ametekesp.com\/surgex).\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339703267564,"sku":"UPS-42100-85R","price":23999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/surgex-ups-42100-85r-single-phase-ups-front.png?v=1789078372"},{"product_id":"surgex-ups-2200-li-iso-ups-with-isolation-transformer-120v","title":"SurgeX UPS-2200-LI-ISO (58220-65R) – UPS with Isolation Transformer, 120V\/20A","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX UPS-2200-LI-ISO is a rack-mount UPS with a built-in low-impedance isolation transformer, combining line-interactive battery backup with power conditioning in one compact unit. It's built for AV racks and home theater systems that need continuous power and isolated, conditioned electrical service without the footprint of a large-format UPS.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eMost rack-mount UPS units provide battery backup but leave ground and neutral referenced back at the main breaker panel, which can leave sensitive AV gear exposed to noise picked up elsewhere on the branch circuit. The UPS-2200-LI-ISO's low-impedance isolation transformer establishes a new neutral-ground bond at the rack itself rather than at the panel, separating ground and neutral voltage to eliminate the anomalies that cause lockups and downtime on sensitive electronic systems. Line-interactive UPS technology delivers a 0.9 output power factor with true sine-wave output, and a stated 4-millisecond transfer time keeps connected equipment running through a utility outage. The isolation transformer additionally blocks high-frequency electrical noise and harmonics from reaching connected loads, which matters in racks that combine AV signal processing with switched-mode IT power supplies on the same circuit. Advanced SNMP communication capability and a user-friendly GUI support remote monitoring and diagnostics, an auto battery test flags a weakening battery before it fails, and a hot-swappable battery lets a technician replace it without powering down connected equipment. Suitable for both commercial and residential-grade AV installs, the compact, rack-mountable, virtually silent design fits control rooms and home theater racks alike. For AV integrators who need UPS backup and isolation-transformer-grade power conditioning in one rack space rather than two separate devices, that combination is the main draw of the LI-ISO line over a standard UPS.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Low-Impedance Isolation Transformer\u003c\/strong\u003e — Establishes a new neutral-ground bond at the rack, reducing lockups and downtime on sensitive AV and IT equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine-Interactive UPS Technology\u003c\/strong\u003e — 0.9 output power factor with true sine-wave output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Transfer Time\u003c\/strong\u003e — A stated 4ms transfer time to battery during a power event.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarmonic and Noise Filtration\u003c\/strong\u003e — Blocks high-frequency electrical noise and harmonics from reaching connected loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced SNMP Communication\u003c\/strong\u003e — Supports remote monitoring and diagnostics via a user-friendly GUI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto Battery Test and Hot-Swappable Battery\u003c\/strong\u003e — Flags battery degradation early and allows replacement without powering down connected equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUPS-2200-LI-ISO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPS Type\u003c\/td\u003e\n\u003ctd\u003eLine-interactive with built-in isolation transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Factor\u003c\/td\u003e\n\u003ctd\u003e0.9, true sine-wave output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e4ms (stated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement\u003c\/td\u003e\n\u003ctd\u003eSNMP communication, GUI diagnostics, auto battery test, hot-swappable battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRack-mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat does the isolation transformer do that a standard UPS doesn't?\u003c\/strong\u003e\u003cbr\u003eIt establishes a new neutral-ground bond at the rack rather than the main panel, separating ground and neutral voltage to eliminate anomalies that cause lockups and downtime on sensitive electronic systems.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the UPS-2200-LI-ISO installed?\u003c\/strong\u003e\u003cbr\u003eIt mounts in a standard rack space and connects like a conventional rack UPS; no separate panel-level work is required since the isolation transformer is built in.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan the battery be replaced without a shutdown?\u003c\/strong\u003e\u003cbr\u003eYes, the battery is hot-swappable, and an auto battery test flags degradation before it becomes a failure.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it support remote monitoring?\u003c\/strong\u003e\u003cbr\u003eYes, via advanced SNMP communication and a GUI-based diagnostics interface.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can assist with rack installation, SNMP monitoring setup, and ongoing support as part of a service agreement.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's own product-launch materials for the UPS + Isolation Transformer line, as syndicated in AV trade press (the manufacturer's dedicated product page redirected off-domain at the time of writing).\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339703431404,"sku":"58220-65R","price":5889.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/surgex-ups-2200-li-iso-isolation-transformer-ups-front.jpg?v=1789078364"},{"product_id":"surgex-ups-3000-li-iso-ups-with-isolation-transformer-120v","title":"SurgeX UPS-3000-LI-ISO (59300-68R) – UPS with Isolation Transformer, 2760VA, 208V In","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX UPS-3000-LI-ISO is the top-capacity model in SurgeX's rack-mount UPS + Isolation Transformer line, combining line-interactive battery backup with a built-in low-impedance isolation transformer. It's built for AV racks and home theater systems that need continuous power and isolated, conditioned electrical service without the footprint of a large-format UPS.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eMost rack-mount UPS units provide battery backup but leave ground and neutral referenced back at the main breaker panel, which can leave sensitive AV gear exposed to noise picked up elsewhere on the branch circuit. The UPS-3000-LI-ISO's low-impedance isolation transformer establishes a new neutral-ground bond at the rack itself rather than at the panel, separating ground and neutral voltage to eliminate the anomalies that cause lockups and downtime on sensitive electronic systems. As the highest-capacity model in the LI-ISO line, it covers larger racks or higher connected loads than the UPS-1440-LI-ISO or UPS-2200-LI-ISO. Line-interactive UPS technology delivers a 0.9 output power factor with true sine-wave output, and a stated 4-millisecond transfer time keeps connected equipment running through a utility outage. The isolation transformer additionally blocks high-frequency electrical noise and harmonics from reaching connected loads, which matters in racks that combine AV signal processing with switched-mode IT power supplies on the same circuit. Advanced SNMP communication capability and a user-friendly GUI support remote monitoring and diagnostics, an auto battery test flags a weakening battery before it fails, and a hot-swappable battery lets a technician replace it without powering down connected equipment. For AV integrators who need UPS backup and isolation-transformer-grade power conditioning in one rack space rather than two separate devices, that combination is the main draw of the LI-ISO line over a standard UPS.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Low-Impedance Isolation Transformer\u003c\/strong\u003e — Establishes a new neutral-ground bond at the rack, reducing lockups and downtime on sensitive AV and IT equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine-Interactive UPS Technology\u003c\/strong\u003e — 0.9 output power factor with true sine-wave output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Transfer Time\u003c\/strong\u003e — A stated 4ms transfer time to battery during a power event.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarmonic and Noise Filtration\u003c\/strong\u003e — Blocks high-frequency electrical noise and harmonics from reaching connected loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced SNMP Communication\u003c\/strong\u003e — Supports remote monitoring and diagnostics via a user-friendly GUI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto Battery Test and Hot-Swappable Battery\u003c\/strong\u003e — Flags battery degradation early and allows replacement without powering down connected equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighest Capacity in the LI-ISO Line\u003c\/strong\u003e — Covers larger racks or higher connected loads than the UPS-1440 or UPS-2200 models.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003cli\u003eMulti-purpose room\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUPS-3000-LI-ISO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPS Type\u003c\/td\u003e\n\u003ctd\u003eLine-interactive with built-in isolation transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Factor\u003c\/td\u003e\n\u003ctd\u003e0.9, true sine-wave output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e4ms (stated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement\u003c\/td\u003e\n\u003ctd\u003eSNMP communication, GUI diagnostics, auto battery test, hot-swappable battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRack-mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat does the isolation transformer do that a standard UPS doesn't?\u003c\/strong\u003e\u003cbr\u003eIt establishes a new neutral-ground bond at the rack rather than the main panel, separating ground and neutral voltage to eliminate anomalies that cause lockups and downtime on sensitive electronic systems.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow does the UPS-3000-LI-ISO compare to the UPS-2200-LI-ISO?\u003c\/strong\u003e\u003cbr\u003eIt's the higher-capacity model in the same LI-ISO line, sized for larger racks or higher connected loads while sharing the same isolation transformer and line-interactive technology.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan the battery be replaced without a shutdown?\u003c\/strong\u003e\u003cbr\u003eYes, the battery is hot-swappable, and an auto battery test flags degradation before it becomes a failure.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it support remote monitoring?\u003c\/strong\u003e\u003cbr\u003eYes, via advanced SNMP communication and a GUI-based diagnostics interface.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can assist with rack installation, SNMP monitoring setup, and ongoing support as part of a service agreement.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's own product-launch materials for the UPS + Isolation Transformer line, as syndicated in AV trade press (the manufacturer's dedicated product page redirected off-domain at the time of writing).\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339703562476,"sku":"59300-68R","price":7029.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/surgex-ups-3000-li-iso-isolation-transformer-ups-front.jpg?v=1789078364"},{"product_id":"surgex-sx-vs-128-vertical-series-pdu-120v","title":"SurgeX SX-VS-128 Vertical Series+ PDU, 120V","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-VS-128 is a fully IP-controlled Vertical Series+ 0U rack PDU with remote power management and analytical software built in. It's an 8-outlet vertical power distribution unit for AV and IT racks that need side-mounted outlet capacity without consuming horizontal rack units.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eVertical, 0U-mount PDUs solve a common rack-space problem: every horizontal rack unit used for power distribution is a unit not available for AV or IT gear. The SX-VS-128 mounts vertically along the side of the rack, carrying a 12A\/5-15P plug feeding 8 individually switchable 5-15R outlets on a 9-foot (2.75m) cord. Remote turn on\/off, power cycling, and sequencing let a technician manage connected equipment from a network dashboard rather than physically accessing the rack. Advanced scheduling, AutoPing device checks, and threshold-triggered events automate routine resets and alerts, eliminating the need for costly and time-consuming onsite service calls for issues that a remote power cycle can resolve. Remote power management and analytics give facilities visibility into per-outlet current draw, and seamless integration with third-party control systems plus SurgeX CONNECT compatibility means the unit reports into an existing control platform rather than requiring its own dedicated interface. For AV integrators building racks with tight horizontal space — broadcast racks, control rooms, and multi-rack deployments — the SX-VS-128 provides IP-controlled outlet switching without consuming rack units that could otherwise hold equipment.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 Outlet Configuration\u003c\/strong\u003e — Individually switchable 5-15R outlets on a vertical, 0U-mount PDU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndividually Switchable Receptacles\u003c\/strong\u003e — Cycle or schedule each outlet independently for targeted device control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Turn On\/Off, Power Cycling, and Sequencing\u003c\/strong\u003e — Manage connected equipment without a site visit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Scheduling, AutoPing, and Threshold-Triggered Events\u003c\/strong\u003e — Reduces onsite service calls for issues remote power cycling can resolve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Power Management and Analytics\u003c\/strong\u003e — Per-outlet visibility into current draw.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThird-Party and SurgeX CONNECT Integration\u003c\/strong\u003e — Reports into existing control systems and SurgeX's cloud platform.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-VS-128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount\u003c\/td\u003e\n\u003ctd\u003eVertical, 0U rack-side mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Configuration\u003c\/td\u003e\n\u003ctd\u003e12A \/ 5-15P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Configuration\u003c\/td\u003e\n\u003ctd\u003e8 Outlets \/ 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e9ft (2.75m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eIP-controlled; SurgeX CONNECT and third-party integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat control systems is the SX-VS-128 compatible with?\u003c\/strong\u003e\u003cbr\u003eIt integrates with SurgeX CONNECT and standard third-party control systems, so it can report into an existing rack or room controller.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the SX-VS-128 mounted?\u003c\/strong\u003e\u003cbr\u003eIt mounts vertically along the side of the rack (0U), preserving horizontal rack space for AV and IT equipment.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan outlets be scheduled or automated?\u003c\/strong\u003e\u003cbr\u003eYes. Advanced scheduling, AutoPing device checks, and threshold-triggered events let the unit take automated action without manual intervention.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it require network access to provide basic power distribution?\u003c\/strong\u003e\u003cbr\u003eNo. Outlets provide power without a network connection; connectivity is required for remote control, scheduling, and analytics.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can assist with configuration, network integration, and troubleshooting for SurgeX power management products as part of a project scope of work.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official Vertical Series+ product page (ametekesp.com\/surgex).\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339703726316,"sku":"SX-VS-128","price":849.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/surgex-sx-vs-128-vertical-pdu-front.jpg?v=1789078364"},{"product_id":"surgex-sx-vs-1216-vertical-series-pdu-120v","title":"SurgeX SX-VS-1216 Vertical Series+ PDU, 120V","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-VS-1216 is a fully IP-controlled Vertical Series+ 0U rack PDU with remote power management and analytical software built in. It's a 16-outlet vertical power distribution unit for AV and IT racks that need higher outlet density without consuming horizontal rack units.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eVertical, 0U-mount PDUs solve a common rack-space problem: every horizontal rack unit used for power distribution is a unit not available for AV or IT gear. The SX-VS-1216 mounts vertically along the side of the rack, carrying a 12A\/5-15P plug feeding 16 individually switchable 5-15R outlets on a 9-foot (2.75m) cord, doubling the outlet count of the SX-VS-128 for larger or more densely populated racks. Remote turn on\/off, power cycling, and sequencing let a technician manage connected equipment from a network dashboard rather than physically accessing the rack. Advanced scheduling, AutoPing device checks, and threshold-triggered events automate routine resets and alerts, eliminating the need for costly and time-consuming onsite service calls for issues that a remote power cycle can resolve. Remote power management and analytics give facilities visibility into per-outlet current draw, and seamless integration with third-party control systems plus SurgeX CONNECT compatibility means the unit reports into an existing control platform rather than requiring its own dedicated interface. For AV integrators building larger racks with tight horizontal space — broadcast racks, control rooms, and multi-rack deployments — the SX-VS-1216 provides high-density IP-controlled outlet switching without consuming rack units that could otherwise hold equipment.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Outlet Configuration\u003c\/strong\u003e — Individually switchable 5-15R outlets on a vertical, 0U-mount PDU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndividually Switchable Receptacles\u003c\/strong\u003e — Cycle or schedule each outlet independently for targeted device control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Turn On\/Off, Power Cycling, and Sequencing\u003c\/strong\u003e — Manage connected equipment without a site visit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Scheduling, AutoPing, and Threshold-Triggered Events\u003c\/strong\u003e — Reduces onsite service calls for issues remote power cycling can resolve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Power Management and Analytics\u003c\/strong\u003e — Per-outlet visibility into current draw.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThird-Party and SurgeX CONNECT Integration\u003c\/strong\u003e — Reports into existing control systems and SurgeX's cloud platform.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-VS-1216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount\u003c\/td\u003e\n\u003ctd\u003eVertical, 0U rack-side mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Configuration\u003c\/td\u003e\n\u003ctd\u003e12A \/ 5-15P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Configuration\u003c\/td\u003e\n\u003ctd\u003e16 Outlets \/ 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e9ft (2.75m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eIP-controlled; SurgeX CONNECT and third-party integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat control systems is the SX-VS-1216 compatible with?\u003c\/strong\u003e\u003cbr\u003eIt integrates with SurgeX CONNECT and standard third-party control systems, so it can report into an existing rack or room controller.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the SX-VS-1216 mounted?\u003c\/strong\u003e\u003cbr\u003eIt mounts vertically along the side of the rack (0U), preserving horizontal rack space for AV and IT equipment.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan outlets be scheduled or automated?\u003c\/strong\u003e\u003cbr\u003eYes. Advanced scheduling, AutoPing device checks, and threshold-triggered events let the unit take automated action without manual intervention.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow does this differ from the SX-VS-128?\u003c\/strong\u003e\u003cbr\u003eThe SX-VS-1216 doubles the outlet count to 16, for racks with more connected devices than the 8-outlet SX-VS-128 can support.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can assist with configuration, network integration, and troubleshooting for SurgeX power management products as part of a project scope of work.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official Vertical Series+ product page (ametekesp.com\/surgex).\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339703890156,"sku":"SX-VS-1216","price":1099.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/surgex-sx-vs-1216-vertical-pdu-front.jpg?v=1789078364"},{"product_id":"surgex-sx-vs-1624-vertical-series-pdu-120v","title":"SurgeX SX-VS-1624 Vertical Series+ PDU, 120V","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-VS-1624 is a fully IP-controlled Vertical Series+ 0U rack PDU with remote power management and analytical software built in. It's a 24-outlet, 20A vertical power distribution unit for large AV and IT racks that need maximum outlet density without consuming horizontal rack units.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eVertical, 0U-mount PDUs solve a common rack-space problem: every horizontal rack unit used for power distribution is a unit not available for AV or IT gear. The SX-VS-1624 mounts vertically along the side of the rack, carrying a 16A\/5-20P plug feeding 24 individually switchable 5-20R outlets on a 9-foot (2.75m) cord, the top-capacity model in the Vertical Series+ line for racks running 20A-rated equipment at high outlet density. Remote turn on\/off, power cycling, and sequencing let a technician manage connected equipment from a network dashboard rather than physically accessing the rack. Advanced scheduling, AutoPing device checks, and threshold-triggered events automate routine resets and alerts, eliminating the need for costly and time-consuming onsite service calls for issues that a remote power cycle can resolve. Remote power management and analytics give facilities visibility into per-outlet current draw, and seamless integration with third-party control systems plus SurgeX CONNECT compatibility means the unit reports into an existing control platform rather than requiring its own dedicated interface. For AV integrators building large broadcast racks, control rooms, or data closets with 20A equipment and tight horizontal rack space, the SX-VS-1624 provides the highest-density IP-controlled outlet switching in the line.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 Outlet Configuration\u003c\/strong\u003e — Individually switchable 5-20R outlets on a vertical, 0U-mount PDU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndividually Switchable Receptacles\u003c\/strong\u003e — Cycle or schedule each outlet independently for targeted device control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Turn On\/Off, Power Cycling, and Sequencing\u003c\/strong\u003e — Manage connected equipment without a site visit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Scheduling, AutoPing, and Threshold-Triggered Events\u003c\/strong\u003e — Reduces onsite service calls for issues remote power cycling can resolve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Power Management and Analytics\u003c\/strong\u003e — Per-outlet visibility into current draw.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThird-Party and SurgeX CONNECT Integration\u003c\/strong\u003e — Reports into existing control systems and SurgeX's cloud platform.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eCommercial meeting space\u003c\/li\u003e\n\u003cli\u003eBroadcast studio\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable style=\"table-layout:fixed;width:100%;min-width:280px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSX-VS-1624\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount\u003c\/td\u003e\n\u003ctd\u003eVertical, 0U rack-side mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Configuration\u003c\/td\u003e\n\u003ctd\u003e16A \/ 5-20P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Configuration\u003c\/td\u003e\n\u003ctd\u003e24 Outlets \/ 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord Length\u003c\/td\u003e\n\u003ctd\u003e9ft (2.75m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eIP-controlled; SurgeX CONNECT and third-party integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat control systems is the SX-VS-1624 compatible with?\u003c\/strong\u003e\u003cbr\u003eIt integrates with SurgeX CONNECT and standard third-party control systems, so it can report into an existing rack or room controller.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the SX-VS-1624 mounted?\u003c\/strong\u003e\u003cbr\u003eIt mounts vertically along the side of the rack (0U), preserving horizontal rack space for AV and IT equipment.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it support 20A-rated equipment?\u003c\/strong\u003e\u003cbr\u003eYes. The 16A\/5-20P plug and 5-20R outlets are built for racks running 20A-rated AV or IT gear.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan outlets be scheduled or automated?\u003c\/strong\u003e\u003cbr\u003eYes. Advanced scheduling, AutoPing device checks, and threshold-triggered events let the unit take automated action without manual intervention.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat warranty does SurgeX provide?\u003c\/strong\u003e\u003cbr\u003eSurgeX publishes its current warranty terms on ametekesp.com; contact Creation Networks for the specific coverage period applicable to this model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat support does Creation Networks provide after installation?\u003c\/strong\u003e\u003cbr\u003eCreation Networks can assist with configuration, network integration, and troubleshooting for SurgeX power management products as part of a project scope of work.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSpecifications sourced from SurgeX's official Vertical Series+ product page (ametekesp.com\/surgex).\u003c\/em\u003e\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default","offer_id":48339704086764,"sku":"SX-VS-1624","price":1379.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/surgex-sx-vs-1624-vertical-pdu-front.jpg?v=1789078364"},{"product_id":"surgex-sx-sa15vs8","title":"SurgeX SX-SA15VS8 – SA-15 + SX-VS-128 Surge \u0026 PDU Bundle","description":"\u003ch2\u003eWhat is the SurgeX SX-SA15VS8?\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-SA15VS8 is a factory bundle that pairs the \u003ca href=\"\/products\/surgex-sa-15-standalone-surge-eliminator-120v-15a\"\u003eSurgeX SA-15\u003c\/a\u003e Standalone surge eliminator and power conditioner with the \u003ca href=\"\/products\/surgex-sx-vs-128-vertical-series-pdu-120v\"\u003eSurgeX SX-VS-128\u003c\/a\u003e Vertical Series+ IP-controlled vertical PDU. It is built for AV and IT racks that need series-mode surge elimination and 8-outlet managed power distribution under one part number. Ordering the bundle keeps the protection stage and the outlet-switching PDU matched and quoted on a single line.\u003c\/p\u003e\n\u003ch2\u003eHow does the SurgeX SX-SA15VS8 work?\u003c\/h2\u003e\u003cp\u003eThe SA-15 sits upstream and uses SurgeX Advanced Series Mode technology to stop surges up to 6,000 volts without dumping energy onto the ground wire. Its output feeds the SX-VS-128, a 0U Vertical Series+ PDU that mounts along the side rail and carries 8 individually switchable receptacles. Because the Vertical Series+ PDU is IP-controlled, each outlet can be turned on, off, or power-cycled remotely, scheduled, or sequenced, and the unit reports into SurgeX CONNECT and third-party control systems. For integrators, the bundle answers two rack questions at once: how the rack is protected from surges and line noise, and how outlets get managed without spending rack units. The SX-VS-128 is rated 120V\/12A on the distribution side.\u003c\/p\u003e\n\u003ch2\u003eWhat are the key features of the SurgeX SX-SA15VS8?\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne part number\u003c\/strong\u003e — The protection stage and the managed PDU ship and quote together.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP-controlled outlets\u003c\/strong\u003e — Every receptacle on the Vertical Series+ PDU can be switched or cycled over the network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0U vertical mounting\u003c\/strong\u003e — The PDU rides the side rail, leaving rack units free for equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurgeX CONNECT compatible\u003c\/strong\u003e — Power status and control report into SurgeX CONNECT and third-party control systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Series Mode\u003c\/strong\u003e — Non-sacrificial surge elimination that does not wear out or contaminate ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI\/RFI filtering\u003c\/strong\u003e — Impedance-tolerant filtration reduces line noise that causes hum and pixelation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhere is the SurgeX SX-SA15VS8 typically used?\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eHouse of worship\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable border=\"1\" cellpadding=\"6\" style=\"border-collapse:collapse;min-width:320px\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSX-SA15VS8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1x SA-15, 1x SX-VS-128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePDU rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120V\/12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePDU receptacles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat comes in the SurgeX SX-SA15VS8 bundle?\u003c\/h3\u003e\u003cp\u003eOne SA-15 and one SX-VS-128 Vertical Series+ vertical PDU.\u003c\/p\u003e\u003ch3\u003eCan the outlets on the SX-SA15VS8 be controlled remotely?\u003c\/h3\u003e\u003cp\u003eYes. The Vertical Series+ PDU is IP-controlled, so outlets can be switched, cycled, scheduled or sequenced over the network.\u003c\/p\u003e\u003ch3\u003eDoes Creation Networks install and configure SurgeX power systems?\u003c\/h3\u003e\u003cp\u003eYes. We design, install and commission rack power as part of complete AV systems nationwide.\u003c\/p\u003e\n\u003cp\u003eBrowse the full \u003ca href=\"\/collections\/surgex\"\u003eSurgeX power protection lineup\u003c\/a\u003e, or call Creation Networks at (888) 230-3661 or email sales@creationnetworks.net for design, quoting and installation.\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":67722562863340,"sku":"SX-SA15VS8","price":1679.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/SX-SA15VS8__39732.1763731299.jpg?v=1791935505"},{"product_id":"surgex-sx-sa15vs16","title":"SurgeX SX-SA15VS16 – SA-15 + SX-VS-1216 Surge \u0026 PDU Bundle","description":"\u003ch2\u003eWhat is the SurgeX SX-SA15VS16?\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-SA15VS16 is a factory bundle that pairs the \u003ca href=\"\/products\/surgex-sa-15-standalone-surge-eliminator-120v-15a\"\u003eSurgeX SA-15\u003c\/a\u003e Standalone surge eliminator and power conditioner with the \u003ca href=\"\/products\/surgex-sx-vs-1216-vertical-series-pdu-120v\"\u003eSurgeX SX-VS-1216\u003c\/a\u003e Vertical Series+ IP-controlled vertical PDU. It is built for AV and IT racks that need series-mode surge elimination and 16-outlet managed power distribution under one part number. Ordering the bundle keeps the protection stage and the outlet-switching PDU matched and quoted on a single line.\u003c\/p\u003e\n\u003ch2\u003eHow does the SurgeX SX-SA15VS16 work?\u003c\/h2\u003e\u003cp\u003eThe SA-15 sits upstream and uses SurgeX Advanced Series Mode technology to stop surges up to 6,000 volts without dumping energy onto the ground wire. Its output feeds the SX-VS-1216, a 0U Vertical Series+ PDU that mounts along the side rail and carries 16 individually switchable receptacles. Because the Vertical Series+ PDU is IP-controlled, each outlet can be turned on, off, or power-cycled remotely, scheduled, or sequenced, and the unit reports into SurgeX CONNECT and third-party control systems. For integrators, the bundle answers two rack questions at once: how the rack is protected from surges and line noise, and how outlets get managed without spending rack units. The SX-VS-1216 is rated 120V\/12A on the distribution side.\u003c\/p\u003e\n\u003ch2\u003eWhat are the key features of the SurgeX SX-SA15VS16?\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne part number\u003c\/strong\u003e — The protection stage and the managed PDU ship and quote together.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP-controlled outlets\u003c\/strong\u003e — Every receptacle on the Vertical Series+ PDU can be switched or cycled over the network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0U vertical mounting\u003c\/strong\u003e — The PDU rides the side rail, leaving rack units free for equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurgeX CONNECT compatible\u003c\/strong\u003e — Power status and control report into SurgeX CONNECT and third-party control systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Series Mode\u003c\/strong\u003e — Non-sacrificial surge elimination that does not wear out or contaminate ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI\/RFI filtering\u003c\/strong\u003e — Impedance-tolerant filtration reduces line noise that causes hum and pixelation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhere is the SurgeX SX-SA15VS16 typically used?\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eHouse of worship\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable border=\"1\" cellpadding=\"6\" style=\"border-collapse:collapse;min-width:320px\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSX-SA15VS16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1x SA-15, 1x SX-VS-1216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePDU rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120V\/12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePDU receptacles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat comes in the SurgeX SX-SA15VS16 bundle?\u003c\/h3\u003e\u003cp\u003eOne SA-15 and one SX-VS-1216 Vertical Series+ vertical PDU.\u003c\/p\u003e\u003ch3\u003eCan the outlets on the SX-SA15VS16 be controlled remotely?\u003c\/h3\u003e\u003cp\u003eYes. The Vertical Series+ PDU is IP-controlled, so outlets can be switched, cycled, scheduled or sequenced over the network.\u003c\/p\u003e\u003ch3\u003eDoes Creation Networks install and configure SurgeX power systems?\u003c\/h3\u003e\u003cp\u003eYes. We design, install and commission rack power as part of complete AV systems nationwide.\u003c\/p\u003e\n\u003cp\u003eBrowse the full \u003ca href=\"\/collections\/surgex\"\u003eSurgeX power protection lineup\u003c\/a\u003e, or call Creation Networks at (888) 230-3661 or email sales@creationnetworks.net for design, quoting and installation.\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":67722562896108,"sku":"SX-SA15VS16","price":1919.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/SX-SA15VS16__44929.1763731316.jpg?v=1791935506"},{"product_id":"surgex-sx-sa20vs8","title":"SurgeX SX-SA20VS8 – SA-20 + SX-VS-128 Surge \u0026 PDU Bundle","description":"\u003ch2\u003eWhat is the SurgeX SX-SA20VS8?\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-SA20VS8 is a factory bundle that pairs the \u003ca href=\"\/products\/surgex-sa-20-standalone-surge-eliminator-120v-20a\"\u003eSurgeX SA-20\u003c\/a\u003e Standalone surge eliminator and power conditioner with the \u003ca href=\"\/products\/surgex-sx-vs-128-vertical-series-pdu-120v\"\u003eSurgeX SX-VS-128\u003c\/a\u003e Vertical Series+ IP-controlled vertical PDU. It is built for AV and IT racks that need series-mode surge elimination and 8-outlet managed power distribution under one part number. Ordering the bundle keeps the protection stage and the outlet-switching PDU matched and quoted on a single line.\u003c\/p\u003e\n\u003ch2\u003eHow does the SurgeX SX-SA20VS8 work?\u003c\/h2\u003e\u003cp\u003eThe SA-20 sits upstream and uses SurgeX Advanced Series Mode technology to stop surges up to 6,000 volts without dumping energy onto the ground wire. Its output feeds the SX-VS-128, a 0U Vertical Series+ PDU that mounts along the side rail and carries 8 individually switchable receptacles. Because the Vertical Series+ PDU is IP-controlled, each outlet can be turned on, off, or power-cycled remotely, scheduled, or sequenced, and the unit reports into SurgeX CONNECT and third-party control systems. For integrators, the bundle answers two rack questions at once: how the rack is protected from surges and line noise, and how outlets get managed without spending rack units. The SX-VS-128 is rated 120V\/12A on the distribution side.\u003c\/p\u003e\n\u003ch2\u003eWhat are the key features of the SurgeX SX-SA20VS8?\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne part number\u003c\/strong\u003e — The protection stage and the managed PDU ship and quote together.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP-controlled outlets\u003c\/strong\u003e — Every receptacle on the Vertical Series+ PDU can be switched or cycled over the network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0U vertical mounting\u003c\/strong\u003e — The PDU rides the side rail, leaving rack units free for equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurgeX CONNECT compatible\u003c\/strong\u003e — Power status and control report into SurgeX CONNECT and third-party control systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Series Mode\u003c\/strong\u003e — Non-sacrificial surge elimination that does not wear out or contaminate ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI\/RFI filtering\u003c\/strong\u003e — Impedance-tolerant filtration reduces line noise that causes hum and pixelation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhere is the SurgeX SX-SA20VS8 typically used?\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eHouse of worship\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable border=\"1\" cellpadding=\"6\" style=\"border-collapse:collapse;min-width:320px\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSX-SA20VS8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1x SA-20, 1x SX-VS-128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePDU rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120V\/12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePDU receptacles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat comes in the SurgeX SX-SA20VS8 bundle?\u003c\/h3\u003e\u003cp\u003eOne SA-20 and one SX-VS-128 Vertical Series+ vertical PDU.\u003c\/p\u003e\u003ch3\u003eCan the outlets on the SX-SA20VS8 be controlled remotely?\u003c\/h3\u003e\u003cp\u003eYes. The Vertical Series+ PDU is IP-controlled, so outlets can be switched, cycled, scheduled or sequenced over the network.\u003c\/p\u003e\u003ch3\u003eDoes Creation Networks install and configure SurgeX power systems?\u003c\/h3\u003e\u003cp\u003eYes. We design, install and commission rack power as part of complete AV systems nationwide.\u003c\/p\u003e\n\u003cp\u003eBrowse the full \u003ca href=\"\/collections\/surgex\"\u003eSurgeX power protection lineup\u003c\/a\u003e, or call Creation Networks at (888) 230-3661 or email sales@creationnetworks.net for design, quoting and installation.\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":67722562994412,"sku":"SX-SA20VS8","price":1699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/SX-SA20VS8__35599.1763731343.jpg?v=1791935507"},{"product_id":"surgex-sx-sa20vs16","title":"SurgeX SX-SA20VS16 – SA-20 + SX-VS-1216 Surge \u0026 PDU Bundle","description":"\u003ch2\u003eWhat is the SurgeX SX-SA20VS16?\u003c\/h2\u003e\u003cp\u003eThe SurgeX SX-SA20VS16 is a factory bundle that pairs the \u003ca href=\"\/products\/surgex-sa-20-standalone-surge-eliminator-120v-20a\"\u003eSurgeX SA-20\u003c\/a\u003e Standalone surge eliminator and power conditioner with the \u003ca href=\"\/products\/surgex-sx-vs-1216-vertical-series-pdu-120v\"\u003eSurgeX SX-VS-1216\u003c\/a\u003e Vertical Series+ IP-controlled vertical PDU. It is built for AV and IT racks that need series-mode surge elimination and 16-outlet managed power distribution under one part number. Ordering the bundle keeps the protection stage and the outlet-switching PDU matched and quoted on a single line.\u003c\/p\u003e\n\u003ch2\u003eHow does the SurgeX SX-SA20VS16 work?\u003c\/h2\u003e\u003cp\u003eThe SA-20 sits upstream and uses SurgeX Advanced Series Mode technology to stop surges up to 6,000 volts without dumping energy onto the ground wire. Its output feeds the SX-VS-1216, a 0U Vertical Series+ PDU that mounts along the side rail and carries 16 individually switchable receptacles. Because the Vertical Series+ PDU is IP-controlled, each outlet can be turned on, off, or power-cycled remotely, scheduled, or sequenced, and the unit reports into SurgeX CONNECT and third-party control systems. For integrators, the bundle answers two rack questions at once: how the rack is protected from surges and line noise, and how outlets get managed without spending rack units. The SX-VS-1216 is rated 120V\/12A on the distribution side.\u003c\/p\u003e\n\u003ch2\u003eWhat are the key features of the SurgeX SX-SA20VS16?\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne part number\u003c\/strong\u003e — The protection stage and the managed PDU ship and quote together.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP-controlled outlets\u003c\/strong\u003e — Every receptacle on the Vertical Series+ PDU can be switched or cycled over the network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0U vertical mounting\u003c\/strong\u003e — The PDU rides the side rail, leaving rack units free for equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurgeX CONNECT compatible\u003c\/strong\u003e — Power status and control report into SurgeX CONNECT and third-party control systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Series Mode\u003c\/strong\u003e — Non-sacrificial surge elimination that does not wear out or contaminate ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI\/RFI filtering\u003c\/strong\u003e — Impedance-tolerant filtration reduces line noise that causes hum and pixelation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhere is the SurgeX SX-SA20VS16 typically used?\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConference room\u003c\/li\u003e\n\u003cli\u003eBoardroom\u003c\/li\u003e\n\u003cli\u003eTraining room\u003c\/li\u003e\n\u003cli\u003eHouse of worship\u003c\/li\u003e\n\u003cli\u003eGovernment space\u003c\/li\u003e\n\u003cli\u003eAuditorium\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable border=\"1\" cellpadding=\"6\" style=\"border-collapse:collapse;min-width:320px\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSX-SA20VS16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1x SA-20, 1x SX-VS-1216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePDU rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120V\/12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePDU receptacles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat comes in the SurgeX SX-SA20VS16 bundle?\u003c\/h3\u003e\u003cp\u003eOne SA-20 and one SX-VS-1216 Vertical Series+ vertical PDU.\u003c\/p\u003e\u003ch3\u003eCan the outlets on the SX-SA20VS16 be controlled remotely?\u003c\/h3\u003e\u003cp\u003eYes. The Vertical Series+ PDU is IP-controlled, so outlets can be switched, cycled, scheduled or sequenced over the network.\u003c\/p\u003e\u003ch3\u003eDoes Creation Networks install and configure SurgeX power systems?\u003c\/h3\u003e\u003cp\u003eYes. We design, install and commission rack power as part of complete AV systems nationwide.\u003c\/p\u003e\n\u003cp\u003eBrowse the full \u003ca href=\"\/collections\/surgex\"\u003eSurgeX power protection lineup\u003c\/a\u003e, or call Creation Networks at (888) 230-3661 or email sales@creationnetworks.net for design, quoting and installation.\u003c\/p\u003e","brand":"SurgeX","offers":[{"title":"Default Title","offer_id":67722563027180,"sku":"SX-SA20VS16","price":1939.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/SX-SA20VS16__84225.1763731363.jpg?v=1791935508"}],"url":"https:\/\/creationnetworks.net\/collections\/surgex.oembed?page=6","provider":"Creation Networks","version":"1.0","type":"link"}