{"title":"Eaton | Diversified power management","description":"\u003ch1\u003eEaton Power Management and Rack PDU Solutions\u003c\/h1\u003e\u003cp\u003eEaton manufactures uninterruptible power supplies, managed and metered rack PDUs, surge protection, and power-management software for data centers, AV head-end rooms, and mission-critical installations. Creation Networks stocks the current catalog for U.S. integrators. For SKU selection and pricing, contact us through \u003ca href=\"https:\/\/creationnetworks.net\/pages\/contact\"\u003ecreationnetworks.net\u003c\/a\u003e.\u003c\/p\u003e\u003ch2\u003eProduct Families\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e9PX UPS\u003c\/strong\u003e — high-efficiency on-line double-conversion UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5P \/ 5PX UPS\u003c\/strong\u003e — line-interactive UPS for AV and IT racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManaged Rack PDUs\u003c\/strong\u003e — networked PDUs with per-outlet switching and metering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetered Rack PDUs\u003c\/strong\u003e — input and outlet metered PDUs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelligent Power Manager Software\u003c\/strong\u003e — fleet management for power infrastructure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessories\u003c\/strong\u003e — replacement batteries, network cards, and rack hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCorporate AV head-end and control rooms\u003c\/li\u003e\n\u003cli\u003eHigher-education data centers and AV head-ends\u003c\/li\u003e\n\u003cli\u003eBroadcast facilities and master control rooms\u003c\/li\u003e\n\u003cli\u003eGovernment and command-center power infrastructure\u003c\/li\u003e\n\u003cli\u003eHealthcare and life-safety power continuity\u003c\/li\u003e\n\u003cli\u003eHospitality back-of-house AV racks\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eProject Support\u003c\/h2\u003e\u003cp\u003eFor SKU selection or quotes, contact us through our \u003ca href=\"https:\/\/creationnetworks.net\/pages\/contact\"\u003econtact page\u003c\/a\u003e or visit \u003ca href=\"https:\/\/creationnetworks.net\"\u003ecreationnetworks.net\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"eaton-ema113-10-managed-rack-pdu-1-92-kw-max-120v-16a-0u-8-outlet-single-phase-pdu","title":"Eaton EMA113-10 – 8-Outlet 120V Managed Rack PDU","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton EMA113-10 is a 0U vertical 120V single-phase managed rack PDU rated to 1.92 kW (16A) across 8 NEMA 5-20R outlets. With dual NEMA 5-20P \/ L5-20P input compatibility, per-outlet switching and metering, and network management, it fits AV racks, edge cabinets, and data center deployments. As a fully featured managed rack PDU, it brings outlet-level switching, network monitoring, and a compact 0U vertical form factor to commercial AV and IT racks. It is engineered for 120V single-phase power distribution where remote reboot, capacity planning, and per-outlet metering reduce on-site service trips.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMA113-10_C.jpg?v=1775839856\" alt=\"Eaton EMA113-10 – 8-Outlet 120V Managed Rack PDU\" loading=\"lazy\" style=\"max-width:100%;height:auto;border:1px solid #eee;border-radius:6px;margin:6px 0;\"\u003e\u003cp\u003eThe Eaton EMA113-10 is part of Eaton's ePDU G3 Managed family, the most fully featured tier of Eaton rack PDUs. It combines input metering, outlet-level metering, and outlet switching so integrators and IT teams can turn individual receptacles on, off, or through a controlled reboot from anywhere on the network. Power, current, voltage, and energy data support load balancing, capacity planning, and energy reporting across the cabinet.\u003c\/p\u003e\u003cp\u003eThis model distributes 1.92 kW (16A, 120V) through (8) NEMA 5-20R outlets and accepts a NEMA 5-20P \/ L5-20P input on a 10 ft cord. A hot-swappable LCD pixel display reports load locally, while the network (RJ-45) interface and RS-232 serial port handle remote management. Up to four ePDUs can be daisy-chained to share a single network connection and IP address, cutting switch-port and cabling costs in dense deployments.\u003c\/p\u003e\u003cp\u003eBuilt for commercial-grade, 24\/7 operation, the EMA113-10 is UL Listed and TAA-compliant, and is rated for ambient temperatures up to 60°C (140°F) for hot-aisle containment and high-temperature network closets. For other outlet counts and input options, compare it with the \u003ca href=\"https:\/\/creationnetworks.net\/products\/eaton-ema114-10-eaton-managed-pdu\"\u003eEaton EMA114-10\u003c\/a\u003e and \u003ca href=\"https:\/\/creationnetworks.net\/products\/eaton-ema111-10-eaton-managed-pdu\"\u003eEaton EMA111-10\u003c\/a\u003e, or browse the full \u003ca href=\"https:\/\/creationnetworks.net\/collections\/eaton\"\u003eEaton power distribution collection\u003c\/a\u003e at Creation Networks.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePer-outlet switching\u003c\/strong\u003e — Turn individual outlets on, off, or through a controlled reboot remotely to recover hung equipment without a site visit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlet-level metering\u003c\/strong\u003e — Measures current, voltage, power, and energy at each outlet for load balancing, capacity planning, and energy reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork and serial management\u003c\/strong\u003e — An RJ-45 network port and RS-232 serial interface allow secure remote monitoring and configuration of the PDU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-swap LCD display\u003c\/strong\u003e — A local LCD pixel display shows real-time load and lets technicians set parameters such as IP address and display orientation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaisy-chain ready\u003c\/strong\u003e — Link up to four ePDUs on one network connection and IP address to reduce switch ports and installation cost in dense racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(8) NEMA 5-20R outlets\u003c\/strong\u003e — Delivers 1.92 kW at 16A, 120V for rack power distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-temperature rating\u003c\/strong\u003e — UL rated for operation up to 60°C (140°F), suitable for hot-aisle containment and warm network closets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial-grade build\u003c\/strong\u003e — TAA Compliant and UL Listed, backed by a 3-year manufacturer warranty for commercial deployment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAV equipment racks and broadcast studios\u003c\/li\u003e\n\u003cli\u003eNetwork and telecom closets\u003c\/li\u003e\n\u003cli\u003eEdge computing and small server cabinets\u003c\/li\u003e\n\u003cli\u003eConference room and huddle room AV racks\u003c\/li\u003e\n\u003cli\u003eGovernment and commercial IT spaces\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 1em;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;min-width:320px;font-size:15px;\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eModel \/ Catalog Number\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eEMA113-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eManaged Rack PDU (ePDU G3 Managed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eForm Factor\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e0U (Vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003ePhase\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003ePower Rating\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e1.92 kW max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eAmperage Rating\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eInput Voltage\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eInput Connection\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eNEMA 5-20P \/ L5-20P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eOutlets\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e(8) NEMA 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eOutlet Control\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eYes (per-outlet switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eCord Length\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e10 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eFrequency\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eNetwork Interface\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eRJ-45 (network managed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eSerial Interface\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e0° to 60°C (32° to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eDimensions (L\/D × H × W)\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e35.5 in × 2.05 in × 2.56 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e6.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eCompliance\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eTAA Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eCertification\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eWarranty\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e3 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eSpecifications sourced from Eaton (eaton.com). Catalog number EMA113-10.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat input plug does the Eaton EMA113-10 require?\u003c\/h3\u003e\u003cp\u003eThe EMA113-10 uses a NEMA 5-20P \/ L5-20P input on a 10 ft cord and operates on 120V single-phase power. Confirm your rack has a matching receptacle or circuit before installation.\u003c\/p\u003e\u003ch3\u003eIs the EMA113-10 currently discounted?\u003c\/h3\u003e\u003cp\u003eYes. The EMA113-10 is offered below the Eaton list price of $1,289, currently $985 at Creation Networks while inventory is available.\u003c\/p\u003e\u003ch3\u003eHow many devices can the EMA113-10 power?\u003c\/h3\u003e\u003cp\u003eIt provides (8) NEMA 5-20R outlets rated to 1.92 kW (16A). Size the connected load to stay within the unit's rating and your branch-circuit capacity.\u003c\/p\u003e\u003ch3\u003eCan I switch and monitor outlets remotely?\u003c\/h3\u003e\u003cp\u003eYes. As an ePDU G3 Managed unit it supports per-outlet on\/off\/reboot switching and outlet-level metering through the RJ-45 network interface, the RS-232 serial port, or the local LCD display.\u003c\/p\u003e\u003ch3\u003eHow does it integrate with our AV or IT management system?\u003c\/h3\u003e\u003cp\u003eThe PDU exposes standard network management over its RJ-45 port and supports daisy-chaining up to four units on one IP address, so it integrates with rack monitoring, DCIM, and remote-reboot workflows used in AV and data center environments.\u003c\/p\u003e\u003ch3\u003eIs the unit rack-mountable in a 0U position?\u003c\/h3\u003e\u003cp\u003eYes. This is a 0U vertical PDU designed to mount in the rear channel of a standard rack or cabinet, keeping rack units free for active equipment.\u003c\/p\u003e\u003ch3\u003eIs the Eaton EMA113-10 TAA compliant?\u003c\/h3\u003e\u003cp\u003eYes. The EMA113-10 is TAA Compliant and UL Listed, making it suitable for government and commercial procurement requirements.\u003c\/p\u003e\u003ch3\u003eWhat warranty and support are included?\u003c\/h3\u003e\u003cp\u003eEaton backs the unit with a 3-year manufacturer warranty. Creation Networks provides pre-sales configuration help and post-sale support; contact our team for integration or volume questions.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47306130981100,"sku":"EMA113-10","price":985.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMA113-10_C.jpg?v=1775839856"},{"product_id":"eaton-ema107-10-eaton-managed-pdu","title":"Eaton EMA107-10 – 24-Outlet Managed Rack PDU, 200–240V","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton EMA107-10 is a high-density, 200–240V single-phase managed rack PDU built for blade servers, colocation cabinets, and high-density data center racks. It delivers 5.76 kW across 24 IEC outlets ((20) C13 and (4) C19) with per-outlet switching and metering over the network. As a fully featured managed rack PDU, it brings outlet-level switching, network monitoring, and a compact 0U vertical form factor to commercial AV and IT racks. It is engineered for 200–240V single-phase power distribution where remote reboot, capacity planning, and per-outlet metering reduce on-site service trips.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMA10710_C.jpg?v=1779925738\" alt=\"Eaton EMA107-10 – 24-Outlet Managed Rack PDU, 200–240V\" loading=\"lazy\" style=\"max-width:100%;height:auto;border:1px solid #eee;border-radius:6px;margin:6px 0;\"\u003e\u003cp\u003eThe Eaton EMA107-10 is part of Eaton's ePDU G3 Managed family, the most fully featured tier of Eaton rack PDUs. It combines input metering, outlet-level metering, and outlet switching so integrators and IT teams can turn individual receptacles on, off, or through a controlled reboot from anywhere on the network. Power, current, voltage, and energy data support load balancing, capacity planning, and energy reporting across the cabinet.\u003c\/p\u003e\u003cp\u003eThis model distributes 5.76 kW (24A, 200–240V) through (20) C13 + (4) C19 outlets and accepts a NEMA L6-30P input on a 10 ft cord. A hot-swappable LCD pixel display reports load locally, while the network (RJ-45) interface and RS-232 serial port handle remote management. Up to four ePDUs can be daisy-chained to share a single network connection and IP address, cutting switch-port and cabling costs in dense deployments.\u003c\/p\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMA10710_DT.jpg?v=1779925738\" alt=\"Eaton EMA107-10 – 24-Outlet Managed Rack PDU, 200–240V detail view\" loading=\"lazy\" style=\"max-width:100%;height:auto;border:1px solid #eee;border-radius:6px;margin:6px 0;\"\u003e\u003cp\u003eBuilt for commercial-grade, 24\/7 operation, the EMA107-10 is UL Listed and TAA-compliant, and is rated for ambient temperatures up to 60°C (140°F) for hot-aisle containment and high-temperature network closets. For other outlet counts and input options, compare it with the \u003ca href=\"https:\/\/creationnetworks.net\/products\/eaton-ema108-10-eaton-managed-pdu\"\u003eEaton EMA108-10\u003c\/a\u003e and \u003ca href=\"https:\/\/creationnetworks.net\/products\/eaton-ema114-10-eaton-managed-pdu\"\u003eEaton EMA114-10\u003c\/a\u003e, or browse the full \u003ca href=\"https:\/\/creationnetworks.net\/collections\/eaton\"\u003eEaton power distribution collection\u003c\/a\u003e at Creation Networks.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePer-outlet switching\u003c\/strong\u003e — Turn individual outlets on, off, or through a controlled reboot remotely to recover hung equipment without a site visit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlet-level metering\u003c\/strong\u003e — Measures current, voltage, power, and energy at each outlet for load balancing, capacity planning, and energy reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork and serial management\u003c\/strong\u003e — An RJ-45 network port and RS-232 serial interface allow secure remote monitoring and configuration of the PDU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-swap LCD display\u003c\/strong\u003e — A local LCD pixel display shows real-time load and lets technicians set parameters such as IP address and display orientation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaisy-chain ready\u003c\/strong\u003e — Link up to four ePDUs on one network connection and IP address to reduce switch ports and installation cost in dense racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(20) C13 + (4) C19 outlets\u003c\/strong\u003e — Delivers 5.76 kW at 24A, 200–240V for high-density power distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-temperature rating\u003c\/strong\u003e — UL rated for operation up to 60°C (140°F), suitable for hot-aisle containment and warm network closets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial-grade build\u003c\/strong\u003e — TAA Compliant and UL Listed, backed by a 3-year manufacturer warranty for commercial deployment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eData center cabinets and server racks\u003c\/li\u003e\n\u003cli\u003eColocation and multi-tenant facilities\u003c\/li\u003e\n\u003cli\u003eNetwork and telecom closets\u003c\/li\u003e\n\u003cli\u003eBroadcast studio and AV equipment racks\u003c\/li\u003e\n\u003cli\u003eGovernment and commercial IT spaces\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 1em;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;min-width:320px;font-size:15px;\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eModel \/ Catalog Number\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eEMA107-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eManaged Rack PDU (ePDU G3 Managed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eForm Factor\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e0U (Vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003ePhase\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003ePower Rating\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e5.76 kW max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eAmperage Rating\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e24A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eInput Voltage\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e200–240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eInput Connection\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eNEMA L6-30P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eOutlets\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e(20) C13 + (4) C19 — IEC grip-lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eOutlet Control\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eYes (per-outlet switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eCord Length\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e10 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eFrequency\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eNetwork Interface\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eRJ-45 (network managed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eSerial Interface\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e0° to 60°C (32° to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eDimensions (L\/D × H × W)\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e2 in × 66.5 in × 2.1 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e17.3 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eCompliance\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eTAA Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eCertification\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eWarranty\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e3 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eSpecifications sourced from Eaton (eaton.com). Catalog number EMA107-10.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat input plug does the Eaton EMA107-10 require?\u003c\/h3\u003e\u003cp\u003eThe EMA107-10 uses a NEMA L6-30P input on a 10 ft cord and operates on 200–240V single-phase power. Confirm your rack has a matching receptacle or circuit before installation.\u003c\/p\u003e\u003ch3\u003eIs the EMA107-10 currently discounted?\u003c\/h3\u003e\u003cp\u003eYes. The EMA107-10 is offered below the Eaton list price of $2,167, currently $975 at Creation Networks while inventory is available.\u003c\/p\u003e\u003ch3\u003eHow many devices can the EMA107-10 power?\u003c\/h3\u003e\u003cp\u003eIt provides (20) C13 + (4) C19 outlets rated to 5.76 kW (24A). Size the connected load to stay within the unit's rating and your branch-circuit capacity.\u003c\/p\u003e\u003ch3\u003eCan I switch and monitor outlets remotely?\u003c\/h3\u003e\u003cp\u003eYes. As an ePDU G3 Managed unit it supports per-outlet on\/off\/reboot switching and outlet-level metering through the RJ-45 network interface, the RS-232 serial port, or the local LCD display.\u003c\/p\u003e\u003ch3\u003eHow does it integrate with our AV or IT management system?\u003c\/h3\u003e\u003cp\u003eThe PDU exposes standard network management over its RJ-45 port and supports daisy-chaining up to four units on one IP address, so it integrates with rack monitoring, DCIM, and remote-reboot workflows used in AV and data center environments.\u003c\/p\u003e\u003ch3\u003eIs the unit rack-mountable in a 0U position?\u003c\/h3\u003e\u003cp\u003eYes. This is a 0U vertical PDU designed to mount in the rear channel of a standard rack or cabinet, keeping rack units free for active equipment.\u003c\/p\u003e\u003ch3\u003eIs the Eaton EMA107-10 TAA compliant?\u003c\/h3\u003e\u003cp\u003eYes. The EMA107-10 is TAA Compliant and UL Listed, making it suitable for government and commercial procurement requirements.\u003c\/p\u003e\u003ch3\u003eWhat warranty and support are included?\u003c\/h3\u003e\u003cp\u003eEaton backs the unit with a 3-year manufacturer warranty. Creation Networks provides pre-sales configuration help and post-sale support; contact our team for integration or volume questions.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47680991363308,"sku":"EMA107-10","price":975.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMA10710_C.jpg?v=1779925738"},{"product_id":"eaton-ema108-10-eaton-managed-pdu","title":"Eaton EMA108-10 – 24-Outlet 120V Managed Rack PDU","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton EMA108-10 is a 120V single-phase managed rack PDU providing 2.88 kW across 24 NEMA 5-20R outlets. With an L5-30P input and per-outlet switching and metering, it suits dense network closets and server racks that run on standard 120V circuits. As a fully featured managed rack PDU, it brings outlet-level switching, network monitoring, and a compact 0U vertical form factor to commercial AV and IT racks. It is engineered for 120V single-phase power distribution where remote reboot, capacity planning, and per-outlet metering reduce on-site service trips.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMA10810_C.jpg?v=1779925890\" alt=\"Eaton EMA108-10 – 24-Outlet 120V Managed Rack PDU\" loading=\"lazy\" style=\"max-width:100%;height:auto;border:1px solid #eee;border-radius:6px;margin:6px 0;\"\u003e\u003cp\u003eThe Eaton EMA108-10 is part of Eaton's ePDU G3 Managed family, the most fully featured tier of Eaton rack PDUs. It combines input metering, outlet-level metering, and outlet switching so integrators and IT teams can turn individual receptacles on, off, or through a controlled reboot from anywhere on the network. Power, current, voltage, and energy data support load balancing, capacity planning, and energy reporting across the cabinet.\u003c\/p\u003e\u003cp\u003eThis model distributes 2.88 kW (24A, 120V) through (24) NEMA 5-20R outlets and accepts a NEMA L5-30P input on a 10 ft cord. A hot-swappable LCD pixel display reports load locally, while the network (RJ-45) interface and RS-232 serial port handle remote management. Up to four ePDUs can be daisy-chained to share a single network connection and IP address, cutting switch-port and cabling costs in dense deployments.\u003c\/p\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMA10810_DT.jpg?v=1779925890\" alt=\"Eaton EMA108-10 – 24-Outlet 120V Managed Rack PDU detail view\" loading=\"lazy\" style=\"max-width:100%;height:auto;border:1px solid #eee;border-radius:6px;margin:6px 0;\"\u003e\u003cp\u003eBuilt for commercial-grade, 24\/7 operation, the EMA108-10 is UL Listed and TAA-compliant, and is rated for ambient temperatures up to 60°C (140°F) for hot-aisle containment and high-temperature network closets. For other outlet counts and input options, compare it with the \u003ca href=\"https:\/\/creationnetworks.net\/products\/eaton-ema107-10-eaton-managed-pdu\"\u003eEaton EMA107-10\u003c\/a\u003e and \u003ca href=\"https:\/\/creationnetworks.net\/products\/eaton-ema114-10-eaton-managed-pdu\"\u003eEaton EMA114-10\u003c\/a\u003e, or browse the full \u003ca href=\"https:\/\/creationnetworks.net\/collections\/eaton\"\u003eEaton power distribution collection\u003c\/a\u003e at Creation Networks.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePer-outlet switching\u003c\/strong\u003e — Turn individual outlets on, off, or through a controlled reboot remotely to recover hung equipment without a site visit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlet-level metering\u003c\/strong\u003e — Measures current, voltage, power, and energy at each outlet for load balancing, capacity planning, and energy reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork and serial management\u003c\/strong\u003e — An RJ-45 network port and RS-232 serial interface allow secure remote monitoring and configuration of the PDU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-swap LCD display\u003c\/strong\u003e — A local LCD pixel display shows real-time load and lets technicians set parameters such as IP address and display orientation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaisy-chain ready\u003c\/strong\u003e — Link up to four ePDUs on one network connection and IP address to reduce switch ports and installation cost in dense racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(24) NEMA 5-20R outlets\u003c\/strong\u003e — Delivers 2.88 kW at 24A, 120V for high-density power distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-temperature rating\u003c\/strong\u003e — UL rated for operation up to 60°C (140°F), suitable for hot-aisle containment and warm network closets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial-grade build\u003c\/strong\u003e — TAA Compliant and UL Listed, backed by a 3-year manufacturer warranty for commercial deployment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eData center cabinets and server racks\u003c\/li\u003e\n\u003cli\u003eColocation and multi-tenant facilities\u003c\/li\u003e\n\u003cli\u003eNetwork and telecom closets\u003c\/li\u003e\n\u003cli\u003eBroadcast studio and AV equipment racks\u003c\/li\u003e\n\u003cli\u003eGovernment and commercial IT spaces\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 1em;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;min-width:320px;font-size:15px;\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eModel \/ Catalog Number\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eEMA108-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eManaged Rack PDU (ePDU G3 Managed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eForm Factor\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e0U (Vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003ePhase\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003ePower Rating\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e2.88 kW max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eAmperage Rating\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e24A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eInput Voltage\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eInput Connection\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eNEMA L5-30P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eOutlets\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e(24) NEMA 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eOutlet Control\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eYes (per-outlet switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eCord Length\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e10 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eFrequency\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eNetwork Interface\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eRJ-45 (network managed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eSerial Interface\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e0° to 60°C (32° to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eDimensions (L\/D × H × W)\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e7.7 in × 9.3 in × 77.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e17.3 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eCompliance\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eTAA Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eCertification\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eWarranty\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e3 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eSpecifications sourced from Eaton (eaton.com). Catalog number EMA108-10.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat input plug does the Eaton EMA108-10 require?\u003c\/h3\u003e\u003cp\u003eThe EMA108-10 uses a NEMA L5-30P input on a 10 ft cord and operates on 120V single-phase power. Confirm your rack has a matching receptacle or circuit before installation.\u003c\/p\u003e\u003ch3\u003eHow many devices can the EMA108-10 power?\u003c\/h3\u003e\u003cp\u003eIt provides (24) NEMA 5-20R outlets rated to 2.88 kW (24A). Size the connected load to stay within the unit's rating and your branch-circuit capacity.\u003c\/p\u003e\u003ch3\u003eCan I switch and monitor outlets remotely?\u003c\/h3\u003e\u003cp\u003eYes. As an ePDU G3 Managed unit it supports per-outlet on\/off\/reboot switching and outlet-level metering through the RJ-45 network interface, the RS-232 serial port, or the local LCD display.\u003c\/p\u003e\u003ch3\u003eHow does it integrate with our AV or IT management system?\u003c\/h3\u003e\u003cp\u003eThe PDU exposes standard network management over its RJ-45 port and supports daisy-chaining up to four units on one IP address, so it integrates with rack monitoring, DCIM, and remote-reboot workflows used in AV and data center environments.\u003c\/p\u003e\u003ch3\u003eIs the unit rack-mountable in a 0U position?\u003c\/h3\u003e\u003cp\u003eYes. This is a 0U vertical PDU designed to mount in the rear channel of a standard rack or cabinet, keeping rack units free for active equipment.\u003c\/p\u003e\u003ch3\u003eIs the Eaton EMA108-10 TAA compliant?\u003c\/h3\u003e\u003cp\u003eYes. The EMA108-10 is TAA Compliant and UL Listed, making it suitable for government and commercial procurement requirements.\u003c\/p\u003e\u003ch3\u003eWhat warranty and support are included?\u003c\/h3\u003e\u003cp\u003eEaton backs the unit with a 3-year manufacturer warranty. Creation Networks provides pre-sales configuration help and post-sale support; contact our team for integration or volume questions.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47680991494380,"sku":"EMA108-10","price":2134.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMA10810_C.jpg?v=1779925890"},{"product_id":"eaton-ema111-10-eaton-managed-pdu","title":"Eaton EMA111-10 – 8-Outlet 120V Managed Rack PDU","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton EMA111-10 is a compact 120V single-phase managed rack PDU delivering 1.44 kW across 8 NEMA 5-15R outlets. Its 5-15P input plugs into a standard 120V wall circuit, making it a fit for AV racks, small server cabinets, and network closets that need remote outlet control. As a fully featured managed rack PDU, it brings outlet-level switching, network monitoring, and a compact 0U vertical form factor to commercial AV and IT racks. It is engineered for 120V single-phase power distribution where remote reboot, capacity planning, and per-outlet metering reduce on-site service trips.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMA11110_C.jpg?v=1779926374\" alt=\"Eaton EMA111-10 – 8-Outlet 120V Managed Rack PDU\" loading=\"lazy\" style=\"max-width:100%;height:auto;border:1px solid #eee;border-radius:6px;margin:6px 0;\"\u003e\u003cp\u003eThe Eaton EMA111-10 is part of Eaton's ePDU G3 Managed family, the most fully featured tier of Eaton rack PDUs. It combines input metering, outlet-level metering, and outlet switching so integrators and IT teams can turn individual receptacles on, off, or through a controlled reboot from anywhere on the network. Power, current, voltage, and energy data support load balancing, capacity planning, and energy reporting across the cabinet.\u003c\/p\u003e\u003cp\u003eThis model distributes 1.44 kW (12A, 120V) through (8) NEMA 5-15R outlets and accepts a NEMA 5-15P input on a 10 ft cord. A hot-swappable LCD pixel display reports load locally, while the network (RJ-45) interface and RS-232 serial port handle remote management. Up to four ePDUs can be daisy-chained to share a single network connection and IP address, cutting switch-port and cabling costs in dense deployments.\u003c\/p\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMA11110_DT.jpg?v=1779926374\" alt=\"Eaton EMA111-10 – 8-Outlet 120V Managed Rack PDU detail view\" loading=\"lazy\" style=\"max-width:100%;height:auto;border:1px solid #eee;border-radius:6px;margin:6px 0;\"\u003e\u003cp\u003eBuilt for commercial-grade, 24\/7 operation, the EMA111-10 is UL Listed and TAA-compliant, and is rated for ambient temperatures up to 60°C (140°F) for hot-aisle containment and high-temperature network closets. For other outlet counts and input options, compare it with the \u003ca href=\"https:\/\/creationnetworks.net\/products\/eaton-ema112-10-eaton-managed-pdu\"\u003eEaton EMA112-10\u003c\/a\u003e and \u003ca href=\"https:\/\/creationnetworks.net\/products\/eaton-ema113-10-managed-rack-pdu-1-92-kw-max-120v-16a-0u-8-outlet-single-phase-pdu\"\u003eEaton EMA113-10\u003c\/a\u003e, or browse the full \u003ca href=\"https:\/\/creationnetworks.net\/collections\/eaton\"\u003eEaton power distribution collection\u003c\/a\u003e at Creation Networks.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePer-outlet switching\u003c\/strong\u003e — Turn individual outlets on, off, or through a controlled reboot remotely to recover hung equipment without a site visit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlet-level metering\u003c\/strong\u003e — Measures current, voltage, power, and energy at each outlet for load balancing, capacity planning, and energy reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork and serial management\u003c\/strong\u003e — An RJ-45 network port and RS-232 serial interface allow secure remote monitoring and configuration of the PDU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-swap LCD display\u003c\/strong\u003e — A local LCD pixel display shows real-time load and lets technicians set parameters such as IP address and display orientation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaisy-chain ready\u003c\/strong\u003e — Link up to four ePDUs on one network connection and IP address to reduce switch ports and installation cost in dense racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(8) NEMA 5-15R outlets\u003c\/strong\u003e — Delivers 1.44 kW at 12A, 120V for rack power distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-temperature rating\u003c\/strong\u003e — UL rated for operation up to 60°C (140°F), suitable for hot-aisle containment and warm network closets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial-grade build\u003c\/strong\u003e — TAA Compliant and UL Listed, backed by a 3-year manufacturer warranty for commercial deployment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAV equipment racks and broadcast studios\u003c\/li\u003e\n\u003cli\u003eNetwork and telecom closets\u003c\/li\u003e\n\u003cli\u003eEdge computing and small server cabinets\u003c\/li\u003e\n\u003cli\u003eConference room and huddle room AV racks\u003c\/li\u003e\n\u003cli\u003eGovernment and commercial IT spaces\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 1em;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;min-width:320px;font-size:15px;\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eModel \/ Catalog Number\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eEMA111-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eManaged Rack PDU (ePDU G3 Managed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eForm Factor\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e0U (Vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003ePhase\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003ePower Rating\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e1.44 kW max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eAmperage Rating\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eInput Voltage\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eInput Connection\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eNEMA 5-15P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eOutlets\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e(8) NEMA 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eOutlet Control\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eYes (per-outlet switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eCord Length\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e10 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eFrequency\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eNetwork Interface\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eRJ-45 (network managed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eSerial Interface\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e0° to 60°C (32° to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eDimensions (L\/D × H × W)\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e35.5 in × 2.05 in × 2.56 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e5.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eCompliance\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eTAA Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eCertification\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eWarranty\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e3 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eSpecifications sourced from Eaton (eaton.com). Catalog number EMA111-10.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat input plug does the Eaton EMA111-10 require?\u003c\/h3\u003e\u003cp\u003eThe EMA111-10 uses a NEMA 5-15P input on a 10 ft cord and operates on 120V single-phase power. Confirm your rack has a matching receptacle or circuit before installation.\u003c\/p\u003e\u003ch3\u003eHow many devices can the EMA111-10 power?\u003c\/h3\u003e\u003cp\u003eIt provides (8) NEMA 5-15R outlets rated to 1.44 kW (12A). Size the connected load to stay within the unit's rating and your branch-circuit capacity.\u003c\/p\u003e\u003ch3\u003eCan I switch and monitor outlets remotely?\u003c\/h3\u003e\u003cp\u003eYes. As an ePDU G3 Managed unit it supports per-outlet on\/off\/reboot switching and outlet-level metering through the RJ-45 network interface, the RS-232 serial port, or the local LCD display.\u003c\/p\u003e\u003ch3\u003eHow does it integrate with our AV or IT management system?\u003c\/h3\u003e\u003cp\u003eThe PDU exposes standard network management over its RJ-45 port and supports daisy-chaining up to four units on one IP address, so it integrates with rack monitoring, DCIM, and remote-reboot workflows used in AV and data center environments.\u003c\/p\u003e\u003ch3\u003eIs the unit rack-mountable in a 0U position?\u003c\/h3\u003e\u003cp\u003eYes. This is a 0U vertical PDU designed to mount in the rear channel of a standard rack or cabinet, keeping rack units free for active equipment.\u003c\/p\u003e\u003ch3\u003eIs the Eaton EMA111-10 TAA compliant?\u003c\/h3\u003e\u003cp\u003eYes. The EMA111-10 is TAA Compliant and UL Listed, making it suitable for government and commercial procurement requirements.\u003c\/p\u003e\u003ch3\u003eWhat warranty and support are included?\u003c\/h3\u003e\u003cp\u003eEaton backs the unit with a 3-year manufacturer warranty. Creation Networks provides pre-sales configuration help and post-sale support; contact our team for integration or volume questions.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47680991658220,"sku":"EMA111-10","price":1201.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMA11110_C.jpg?v=1779926374"},{"product_id":"eaton-ema112-10-eaton-managed-pdu","title":"Eaton EMA112-10 – 16-Outlet 120V Managed Rack PDU","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton EMA112-10 is a 0U vertical 120V single-phase managed rack PDU providing 1.44 kW across 16 NEMA 5-15R outlets. The 5-15P input runs on a standard 120V circuit while per-outlet switching and metering give remote control of every connected device. As a fully featured managed rack PDU, it brings outlet-level switching, network monitoring, and a compact 0U vertical form factor to commercial AV and IT racks. It is engineered for 120V single-phase power distribution where remote reboot, capacity planning, and per-outlet metering reduce on-site service trips.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMA11210_C.jpg?v=1779926113\" alt=\"Eaton EMA112-10 – 16-Outlet 120V Managed Rack PDU\" loading=\"lazy\" style=\"max-width:100%;height:auto;border:1px solid #eee;border-radius:6px;margin:6px 0;\"\u003e\u003cp\u003eThe Eaton EMA112-10 is part of Eaton's ePDU G3 Managed family, the most fully featured tier of Eaton rack PDUs. It combines input metering, outlet-level metering, and outlet switching so integrators and IT teams can turn individual receptacles on, off, or through a controlled reboot from anywhere on the network. Power, current, voltage, and energy data support load balancing, capacity planning, and energy reporting across the cabinet.\u003c\/p\u003e\u003cp\u003eThis model distributes 1.44 kW (12A, 120V) through (16) NEMA 5-15R outlets and accepts a NEMA 5-15P input on a 10 ft cord. A hot-swappable LCD pixel display reports load locally, while the network (RJ-45) interface and RS-232 serial port handle remote management. Up to four ePDUs can be daisy-chained to share a single network connection and IP address, cutting switch-port and cabling costs in dense deployments.\u003c\/p\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMA11210_DT02.jpg?v=1779926113\" alt=\"Eaton EMA112-10 – 16-Outlet 120V Managed Rack PDU detail view\" loading=\"lazy\" style=\"max-width:100%;height:auto;border:1px solid #eee;border-radius:6px;margin:6px 0;\"\u003e\u003cp\u003eBuilt for commercial-grade, 24\/7 operation, the EMA112-10 is UL Listed and RoHS-compliant, and is rated for ambient temperatures up to 60°C (140°F) for hot-aisle containment and high-temperature network closets. For other outlet counts and input options, compare it with the \u003ca href=\"https:\/\/creationnetworks.net\/products\/eaton-ema111-10-eaton-managed-pdu\"\u003eEaton EMA111-10\u003c\/a\u003e and \u003ca href=\"https:\/\/creationnetworks.net\/products\/eaton-ema114-10-eaton-managed-pdu\"\u003eEaton EMA114-10\u003c\/a\u003e, or browse the full \u003ca href=\"https:\/\/creationnetworks.net\/collections\/eaton\"\u003eEaton power distribution collection\u003c\/a\u003e at Creation Networks.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePer-outlet switching\u003c\/strong\u003e — Turn individual outlets on, off, or through a controlled reboot remotely to recover hung equipment without a site visit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlet-level metering\u003c\/strong\u003e — Measures current, voltage, power, and energy at each outlet for load balancing, capacity planning, and energy reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork and serial management\u003c\/strong\u003e — An RJ-45 network port and RS-232 serial interface allow secure remote monitoring and configuration of the PDU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-swap LCD display\u003c\/strong\u003e — A local LCD pixel display shows real-time load and lets technicians set parameters such as IP address and display orientation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaisy-chain ready\u003c\/strong\u003e — Link up to four ePDUs on one network connection and IP address to reduce switch ports and installation cost in dense racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(16) NEMA 5-15R outlets\u003c\/strong\u003e — Delivers 1.44 kW at 12A, 120V for rack power distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-temperature rating\u003c\/strong\u003e — UL rated for operation up to 60°C (140°F), suitable for hot-aisle containment and warm network closets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial-grade build\u003c\/strong\u003e — RoHS Compliant, TAA Compliant and UL Listed, backed by a 3-year manufacturer warranty for commercial deployment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAV equipment racks and broadcast studios\u003c\/li\u003e\n\u003cli\u003eNetwork and telecom closets\u003c\/li\u003e\n\u003cli\u003eEdge computing and small server cabinets\u003c\/li\u003e\n\u003cli\u003eConference room and huddle room AV racks\u003c\/li\u003e\n\u003cli\u003eGovernment and commercial IT spaces\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 1em;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;min-width:320px;font-size:15px;\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eModel \/ Catalog Number\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eEMA112-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eManaged Rack PDU (ePDU G3 Managed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eForm Factor\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e0U (Vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003ePhase\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003ePower Rating\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e1.44 kW max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eAmperage Rating\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eInput Voltage\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eInput Connection\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eNEMA 5-15P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eOutlets\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e(16) NEMA 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eOutlet Control\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eYes (per-outlet switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eCord Length\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e10 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eFrequency\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eNetwork Interface\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eRJ-45 (network managed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eSerial Interface\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e0° to 60°C (32° to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eDimensions (L\/D × H × W)\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e66.5 in × 2.56 in × 2.05 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eCompliance\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eRoHS Compliant, TAA Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eCertification\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eWarranty\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e3 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eSpecifications sourced from Eaton (eaton.com). Catalog number EMA112-10.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat input plug does the Eaton EMA112-10 require?\u003c\/h3\u003e\u003cp\u003eThe EMA112-10 uses a NEMA 5-15P input on a 10 ft cord and operates on 120V single-phase power. Confirm your rack has a matching receptacle or circuit before installation.\u003c\/p\u003e\u003ch3\u003eHow many devices can the EMA112-10 power?\u003c\/h3\u003e\u003cp\u003eIt provides (16) NEMA 5-15R outlets rated to 1.44 kW (12A). Size the connected load to stay within the unit's rating and your branch-circuit capacity.\u003c\/p\u003e\u003ch3\u003eCan I switch and monitor outlets remotely?\u003c\/h3\u003e\u003cp\u003eYes. As an ePDU G3 Managed unit it supports per-outlet on\/off\/reboot switching and outlet-level metering through the RJ-45 network interface, the RS-232 serial port, or the local LCD display.\u003c\/p\u003e\u003ch3\u003eHow does it integrate with our AV or IT management system?\u003c\/h3\u003e\u003cp\u003eThe PDU exposes standard network management over its RJ-45 port and supports daisy-chaining up to four units on one IP address, so it integrates with rack monitoring, DCIM, and remote-reboot workflows used in AV and data center environments.\u003c\/p\u003e\u003ch3\u003eIs the unit rack-mountable in a 0U position?\u003c\/h3\u003e\u003cp\u003eYes. This is a 0U vertical PDU designed to mount in the rear channel of a standard rack or cabinet, keeping rack units free for active equipment.\u003c\/p\u003e\u003ch3\u003eIs the Eaton EMA112-10 TAA compliant?\u003c\/h3\u003e\u003cp\u003eYes. The EMA112-10 is RoHS Compliant, TAA Compliant and UL Listed, making it suitable for government and commercial procurement requirements.\u003c\/p\u003e\u003ch3\u003eWhat warranty and support are included?\u003c\/h3\u003e\u003cp\u003eEaton backs the unit with a 3-year manufacturer warranty. Creation Networks provides pre-sales configuration help and post-sale support; contact our team for integration or volume questions.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47680991723756,"sku":"EMA112-10","price":1355.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMA11210_C.jpg?v=1779926113"},{"product_id":"eaton-ema114-10-eaton-managed-pdu","title":"Eaton EMA114-10 – 24-Outlet 120V Managed Rack PDU","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003eThe Eaton EMA114-10 is a 0U vertical 120V single-phase managed rack PDU rated to 1.92 kW (16A) across 24 NEMA 5-20R outlets. Dual NEMA 5-20P \/ L5-20P input compatibility plus per-outlet switching and metering make it a high-outlet-count choice for server racks and colocation cabinets. As a fully featured managed rack PDU, it brings outlet-level switching, network monitoring, and a compact 0U vertical form factor to commercial AV and IT racks. It is engineered for 120V single-phase power distribution where remote reboot, capacity planning, and per-outlet metering reduce on-site service trips.\u003c\/p\u003e\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMA11410_C.jpg?v=1779925444\" alt=\"Eaton EMA114-10 – 24-Outlet 120V Managed Rack PDU\" loading=\"lazy\" style=\"max-width:100%;height:auto;border:1px solid #eee;border-radius:6px;margin:6px 0;\"\u003e\u003cp\u003eThe Eaton EMA114-10 is part of Eaton's ePDU G3 Managed family, the most fully featured tier of Eaton rack PDUs. It combines input metering, outlet-level metering, and outlet switching so integrators and IT teams can turn individual receptacles on, off, or through a controlled reboot from anywhere on the network. Power, current, voltage, and energy data support load balancing, capacity planning, and energy reporting across the cabinet.\u003c\/p\u003e\u003cp\u003eThis model distributes 1.92 kW (16A, 120V) through (24) NEMA 5-20R outlets and accepts a NEMA 5-20P \/ L5-20P input on a 10 ft cord. A hot-swappable LCD pixel display reports load locally, while the network (RJ-45) interface and RS-232 serial port handle remote management. Up to four ePDUs can be daisy-chained to share a single network connection and IP address, cutting switch-port and cabling costs in dense deployments.\u003c\/p\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMA11410_DT.jpg?v=1779925449\" alt=\"Eaton EMA114-10 – 24-Outlet 120V Managed Rack PDU detail view\" loading=\"lazy\" style=\"max-width:100%;height:auto;border:1px solid #eee;border-radius:6px;margin:6px 0;\"\u003e\u003cp\u003eBuilt for commercial-grade, 24\/7 operation, the EMA114-10 is UL Listed and RoHS-compliant, and is rated for ambient temperatures up to 60°C (140°F) for hot-aisle containment and high-temperature network closets. For other outlet counts and input options, compare it with the \u003ca href=\"https:\/\/creationnetworks.net\/products\/eaton-ema108-10-eaton-managed-pdu\"\u003eEaton EMA108-10\u003c\/a\u003e and \u003ca href=\"https:\/\/creationnetworks.net\/products\/eaton-ema113-10-managed-rack-pdu-1-92-kw-max-120v-16a-0u-8-outlet-single-phase-pdu\"\u003eEaton EMA113-10\u003c\/a\u003e, or browse the full \u003ca href=\"https:\/\/creationnetworks.net\/collections\/eaton\"\u003eEaton power distribution collection\u003c\/a\u003e at Creation Networks.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePer-outlet switching\u003c\/strong\u003e — Turn individual outlets on, off, or through a controlled reboot remotely to recover hung equipment without a site visit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlet-level metering\u003c\/strong\u003e — Measures current, voltage, power, and energy at each outlet for load balancing, capacity planning, and energy reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork and serial management\u003c\/strong\u003e — An RJ-45 network port and RS-232 serial interface allow secure remote monitoring and configuration of the PDU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-swap LCD display\u003c\/strong\u003e — A local LCD pixel display shows real-time load and lets technicians set parameters such as IP address and display orientation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaisy-chain ready\u003c\/strong\u003e — Link up to four ePDUs on one network connection and IP address to reduce switch ports and installation cost in dense racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(24) NEMA 5-20R outlets\u003c\/strong\u003e — Delivers 1.92 kW at 16A, 120V for high-density power distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-temperature rating\u003c\/strong\u003e — UL rated for operation up to 60°C (140°F), suitable for hot-aisle containment and warm network closets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial-grade build\u003c\/strong\u003e — RoHS Compliant, TAA Compliant and UL Listed, backed by a 3-year manufacturer warranty for commercial deployment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTypical Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eData center cabinets and server racks\u003c\/li\u003e\n\u003cli\u003eColocation and multi-tenant facilities\u003c\/li\u003e\n\u003cli\u003eNetwork and telecom closets\u003c\/li\u003e\n\u003cli\u003eBroadcast studio and AV equipment racks\u003c\/li\u003e\n\u003cli\u003eGovernment and commercial IT spaces\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 1em;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;min-width:320px;font-size:15px;\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eModel \/ Catalog Number\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eEMA114-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eManaged Rack PDU (ePDU G3 Managed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eForm Factor\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e0U (Vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003ePhase\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003ePower Rating\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e1.92 kW max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eAmperage Rating\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eInput Voltage\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eInput Connection\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eNEMA 5-20P \/ L5-20P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eOutlets\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e(24) NEMA 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eOutlet Control\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eYes (per-outlet switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eCord Length\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e10 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eFrequency\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eNetwork Interface\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eRJ-45 (network managed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eSerial Interface\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e0° to 60°C (32° to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eDimensions (L\/D × H × W)\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e66.5 in × 2.09 in × 2.05 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e15.9 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eCompliance\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eRoHS Compliant, TAA Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eCertification\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"text-align:left;padding:8px 12px;border:1px solid #ddd;white-space:nowrap;font-weight:600;\"\u003eWarranty\u003c\/th\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e3 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003cp style=\"font-size:13px;color:#666;\"\u003eSpecifications sourced from Eaton (eaton.com). Catalog number EMA114-10.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat input plug does the Eaton EMA114-10 require?\u003c\/h3\u003e\u003cp\u003eThe EMA114-10 uses a NEMA 5-20P \/ L5-20P input on a 10 ft cord and operates on 120V single-phase power. Confirm your rack has a matching receptacle or circuit before installation.\u003c\/p\u003e\u003ch3\u003eHow many devices can the EMA114-10 power?\u003c\/h3\u003e\u003cp\u003eIt provides (24) NEMA 5-20R outlets rated to 1.92 kW (16A). Size the connected load to stay within the unit's rating and your branch-circuit capacity.\u003c\/p\u003e\u003ch3\u003eCan I switch and monitor outlets remotely?\u003c\/h3\u003e\u003cp\u003eYes. As an ePDU G3 Managed unit it supports per-outlet on\/off\/reboot switching and outlet-level metering through the RJ-45 network interface, the RS-232 serial port, or the local LCD display.\u003c\/p\u003e\u003ch3\u003eHow does it integrate with our AV or IT management system?\u003c\/h3\u003e\u003cp\u003eThe PDU exposes standard network management over its RJ-45 port and supports daisy-chaining up to four units on one IP address, so it integrates with rack monitoring, DCIM, and remote-reboot workflows used in AV and data center environments.\u003c\/p\u003e\u003ch3\u003eIs the unit rack-mountable in a 0U position?\u003c\/h3\u003e\u003cp\u003eYes. This is a 0U vertical PDU designed to mount in the rear channel of a standard rack or cabinet, keeping rack units free for active equipment.\u003c\/p\u003e\u003ch3\u003eIs the Eaton EMA114-10 TAA compliant?\u003c\/h3\u003e\u003cp\u003eYes. The EMA114-10 is RoHS Compliant, TAA Compliant and UL Listed, making it suitable for government and commercial procurement requirements.\u003c\/p\u003e\u003ch3\u003eWhat warranty and support are included?\u003c\/h3\u003e\u003cp\u003eEaton backs the unit with a 3-year manufacturer warranty. Creation Networks provides pre-sales configuration help and post-sale support; contact our team for integration or volume questions.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":47680991822060,"sku":"EMA114-10","price":1589.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/files\/EMA11410_C.jpg?v=1779925444"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0603\/7982\/4364\/collections\/Eaton-logo.png?v=1780473034","url":"https:\/\/creationnetworks.net\/collections\/eaton.oembed","provider":"Creation Networks","version":"1.0","type":"link"}